Home > Water Quality > Model Q45H/62-63Residual Chlorine Monitor
Model Q45H/62-63 Residual Chlorine
|
||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
The Q45H system has no moving parts, so there are no pumps or motors that burn out or tubing breaks that create maintenance nightmares. All normal maintenance items are included with each system. The Q45H chlorine monitoring system is easy to operate, requires minimal maintenance and will not eat a hole in your operating budget with on going reagent requirements or component replacement costs. Features
The residual chlorine sensors are available in two configurations: flowcell and submersion. The Free Chlorine sensor should always be used in the flowcell configuration. The Constant Head Flowcell is used to maintain a constant flow rate and pressure at the face of the sensor. The sample inlet flow rate and pressure can vary widely without affecting the measurement. The only requirement is that the sample inlet flow rate be at least 7 gallons per hour. A Low Volume Flowcell is available for clean water application with a flow rate of 3-6 gallons per hour. The Combined Chlorine sensor can be used in either the Flowcell or Submersion configuration. The submersion sensors require flow velocities of at least 0.4 ft/sec for proper operation. For many applications, process pH is relatively stable and nothing more than the standard monitor and sensor are needed. However, when the pH of the water stream varies regularly, a significant error in free chlorine concentration is introduced. This error is due to the sensitivity of the membraned sensor to wide pH fluctuations. With the simple addition of an optional pH sensor, the Q45H will automatically correct for these changes, maintaining accurate measurement even when pH varies widely or is up near a pH of 9. With AC version, this option provides a second analog output that can be assigned to pH, converting the chlorine monitor into a two parameter system, providing isolated 4-20 mA outputs for both chlorine and pH. Both Free and Combined Chlorine monitors can be converted to dual output monitors. The Q45H is designed for exceptional flexibility to meet a variety of monitoring applications. In it simplest form, the unit is a loop powered transmitter operating from standard 24 VDC power supplies. This means easy integration into many DCS, PLC and SCAD systems. Loop powered instruments include the PID output function. For applications where the second analog output is desired or where alarm relay functions are needed, an AC powered system is available. Operation from AC power allows the user to utilize analog outputs for both chlorine dioxide and pH or for independent PID and chlorine dioxide outputs or simply for chlorine dioxide and temperature outputs. For even greater versatility, a portable unit powered by a standard 9V battery is also available. The dual 0-2.5 VDC outputs are assignable to chlorine dioxide concentration and temperature. This instrument can be supplied with an internal data logger, making it ideal for short term monitoring at remote sites. The unit will run for 10 days on a single battery and the data logger will store up to 32,000 data points, easily enough for 10 days of data at 1 minuted intervals. Specifications - Monitor
Specifications - Sensor
Ordering Information
For pricing please call AFC International at 800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
|
||||||||||||||||||||||||||||||||||||||||||||||||||
|
New Products | Air Sampling | Gas Detection | Other Meters | Respiratory | Water Quality | WMD HazMat
Applications | Product Specials | Rentals | Links | Index | Contact Us | Home AFC International, Inc. PO Box 894, DeMotte, IN 46310 715 SW Almond St, Ste C, DeMotte, IN 46310 800-952-3293 219-987-6825 Fax 219-987-6826 eMail: sales@afcintl.com Last Revised: |
|||||||||||||||||||||||||||||||||||||||||||||||||||