Home > Water Quality Products > Model Q45N Dissolved Ammonia Monitor

Model Q45N Dissolved Ammonia Monitor
from Analytical Technology

ATI has developed a completely new approach to on line monitoring of ammonia that is far less expensive and much simpler than conventional monitoring equipment. The Q45N Dissolved Ammonia Monitor uses reaction chemistry that converts ammonia in solution to a stable monochloramine compound equivalent in concentration to the original ammonia level. The chloramine concentration is then measured with a unique amperometric sensor that responds linearly to chloramines while eliminating interference from excess free chlorine in solution.
Model Q45N Dissolved Ammonia Monitor Continuous monitoring of ammonia in water and wastewater streams is becoming increasingly important for plant operations and process control. Unfortunately, on-line ammonia monitors are generally very expensive, complex and labor intensive instruments. Most are automated versions of ammonia selective ion electrode methods better suited to laboratory measurements. Others are automated colorimetric devices of instrumental methods that are difficult to justify on a cost basis.

Q45N monitors are available in two versions, one that includes all components conveniently integrated into a NEMA 4X fiberglass enclosure and a second that separates the monitor from the chemistry system for applications where a more convenient display location is desired. A sample inlet filter assembly attached to the sie of the enclosure allows filtered sample to be drawn from the inlet flow. Sample must be pumped to the inlet assembly at a rate high enough to insure the desired response time for the measurement system. Excess sample is bypassed to any convenient drain location.

The electronic display and alarm package provides the user interface to the system. Ammonia concentration is displayed on a large format LCD display with secondary display for other operating variables. Operating ranges for the ammonia monitor are 0-2 or 0-20 ppm, with a low end resolution of about 0.05 ppm. Response time to changes in ammonia concentration is less than 60 seconds to 90% of a step change in concentration, making the system much faster responding than competitive monitors. Two programmable alarm relays are available for local alarm functions and two analog 4-20 mA output signals are provided for interface to plant DCS, telemetry or other supervisory instrumentation.

ATI's Q45N monitoring package for dissolved ammonia provides the measurement stability needed to avoid complicated automatic calibration systems. Unlike typical ammonia SIE sensors subject to significant drift problems, the amperometric sensor provides excellent repeatability for long periods of time. And because the measurement utilizes chloramine conversion for measurement, the sample is inherently subjected to biocidal conditions, eliminating long term biofouling on the sensor.

This new ammonia system represents a major step forward in providing users with a monitor that is both simple to operate and economical to purchase, selling for 50% of the cost of many competitive ammonia monitors.

Chloramination Process Monitoring

Chloramination is increasingly being used in potable water systems to limit THM formation and insure disinfection in large distribution systems. Proper control of this process requires the addition of sufficient ammonia to insure that only monochloramine is formed while limiting the amount of excess ammonia to a minimum.

An enhanced version of the Q45N Dissolved Ammonia Monitor is available that provides an excellent tool for monitoring the chloramination process. This system employs two separate sensors, the first measuring monochloramine and the second measuring total ammonia after reagent addition. From these measurements, the monitor will calculate "Free Ammonia" concentration, which effectively is the excess ammonia that has not combined with chlorine.

This Free Ammonia version can provide two separate 4-20 mA outputs and those outputs may be programmed to track Free Ammonia, Total Ammonia or Monochloramine concentration. For chloramination systems, it provides operating personnel with continuous confirmation that the process is running correctly or warns of process problems.

Specifications

Measurement Total ammonia as NH3 - N
Optional Free ammonia at NH3 and Monochloramine
Sensor Type Amperometric membraned cell
Range Ammonia: 0-2.000 ppm min, 0-20.00 ppm max
Monochloramine: 0-10.00 ppm
Accuracy +/- 0.1 ppm or 2% of full scale
Response Time 90% in 120 seconds
Sensitivity 0.05 ppm min
Zero Stability +/- 0.02 ppm per week
Electronic Linearity +/- 0.5%
Span Drift Generally less than 5% per month
Zero Drift +/- 0.03 ppm
Analog Output Two isolated 4-20 mA, 575 ohms max
Power 115 or 230 VAC, 50/60 Hz, 5 VA max
Alarm Relays Two SPDT, 5A @ 230 VAC resistive
Relay Coil Programmable either normally energized or normally de-energized
Enclosure Nema 4X Fiberglass wall mount
Controls 4 membrane switches on front of monitor
Temperature 0 to 40°C
Sample Inlet 1/2" FNPT
Sample Drain 1/2" FNPT
Recommended Sample Flow 0.1 - 0.5 GPM (0.4-2.0 LPM)
Size 15.2" H x 13" W x 7.1" D
Weight 17 pounds

Ordering Information

Spare parts and maintenance supplies included for 1 year of use. For pricing please call AFC International at 800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.