Series B20 Residual Chlorine Recorder
from Analytical Technology
Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder. ATI's Series B20 provides an integrated solution to this problem, combining both the analyzer and recorder functions in a single package. This means simpler installation, easier operation and lower cost. And best of all, the system uses a direct measuring membraned sensor for reliable measurement with minimal maintenance.
Free or combined chlorine recording
Selectable 24 hour or 7 day chart
Modular sensor for easy service
Digital concentration display
NEMA 3 wall or panel mount enclosure
Replaceable felt tip chart pens
Direct measuring chlorine sensor
No chemical reagents required
Simple constant head flowcell
Two alarm standard
Series B20 chlorine recorders use the same reliable chlorine sensor supplied for years as part of the Series A15 monitoring systems. The sensor is a direct measuring polarographic membraned sensor that eliminates the need for chemical buffers and other reagents. Sensors are available for free chlorine measurements or for combined chlorine monitoring where chloramine treatment is in use.
Chlorine sensors require a constant sample flow past the membrane to provide stable and accurate readings. B20 systems are supplied with a constant head flowcell assembly that automatically maintains the desired flow. Hose barbs for sample inlet and drain provide for connection of flexible PVC tubing.
Specifications
Range
0-1 to 0-5 ppm or 0-5 to 0-20 ppm
Chart
10" with 0-100% scale, 24 hour scale, package of 100
Chart Speed
Selectable for 24 hour or 7 day
Display
Digital concentration display
Accuracy
+/- 0.05 ppm
Repeatability
+/- 0.02 ppm
Response Time
90% in 60 seconds
Enclosure
NEMA 3 Noryl, acrylic window
Sensor
Polarographic membraned type
Sensor Materials
Noryl and stainless steel
Sensor Cable
25' standard, 100' maximum
Flowcell
Constant head overflow type
Flowcell Materials
Clear acrylic, stainless plate
Inlet
1/4" id tubing hose barb (1/8" FNPT)
Drain
1/2" id tubing hose barb (3/8" FNPT)
Sample Flowrate
15 GPH (7 GPH minimum)
Sample Temperature
0-50°C
Power
120 or 240 VAC, 50/60 Hz, 9 watts
Flowcell Size
4.5" W x 7" H x 3.5" D
Recorder Size
14" W x 7" H x 3.5" D
Alarms
Two programmable alarms
Alarm Relays
Two SPDT, 5A @ 120 VAC resistive
Ordering Information
For pricing information, please contact AFC International at 800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Description
Catalog No.
Series B20 Free Chlorine Recorder, Internal Amplifier, Sensor w/Clear Flowcell, 0-1 or 0-5 ppm
B20/62-1-1-2
Series B20 Free Chlorine Recorder, External Amplifier, Sensor w/Clear Flowcell, 0-1 or 0-5 ppm
B20/62-2-1-2
Series B20 Chloramines Recorder, Internal Amplifier, Sensor w/Clear Flowcell, 0-1 or 0-5 ppm
B20/63-1-1-2
Series B20 Chloramines Recorder, External Amplifier, Sensor w/Clear Flowcell, 0-1 or 0-5 ppm
B20/63-2-1-2
Series B20 Chloramines Recorder, Internal Amplifier, Submersible Sensor, 0-1 or 0-5 ppm
B20/63-1-1-1
Series B20 Chloramines Recorder, External Amplifier, Submersible Sensor, 0-1 or 0-5 ppm
B20/63-2-1-2
Optional high range available, call AFC for details.
AFC International, Inc.
PO Box 894, DeMotte, IN 46310
715 SW Almond St, Ste C, DeMotte, IN 46310
800-952-3293 219-987-6825 Fax 219-987-6826 eMail: sales@afcintl.com