Industries Served
• Industrial |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Home > Respiratory Protection > SCape CBRN30 Escape Hood
NEW!! - SCape CBRN30 Escape Hood
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
The SCape has a protection factor that was completed in accordance with NIOSH Laboratory Respiratory Protection Level (LRPL) test protocol. This test was conducted by the US Army at the Edgewood Chemical Biological Center in Edgewood, MD. The results of the testing demonstrate that extremely high levels of protection are provided by SCape CBRN 30. An average fit factor* (FF) of 97,953 was achieved for the 60 test trials. 52 of the 60 trials had an FF of 100,000 or greater. The minimum FF measured was 66,143 - far exceeding the NIOSH FF requirement of 2,000 or greater.
The SCape is approved by NIOSH as a 30 minute General Category Escape Mask under the Standard for Chemical, Biological, Radiological and Nuclear (CBRN) Air Purifying Escape Respirators (September 30, 2003). NIOSH Approval Number TC-14G-0277 |
|
Test Agent
|
Test Concen-tration
|
%RH
|
Break-through Concen-tration
|
NIOSH Required Service Life (min)
|
Actual Service Life (min)
|
| Ammonia |
1,250 ppm
|
25
80 |
25 ppm
|
30
30 |
>35
>35 |
| Cyanogen Chloride |
150 ppm
|
25
80 |
2 ppm
|
30
30 |
>70
>40 |
| Sulfur Dioxide |
750 ppm
|
25
80 |
5 ppm
|
30
30 |
>35
>35 |
| Cyclohexane |
1,300 ppm
|
25
80 |
10 ppm
|
30
30 |
>65
>45 |
| Formaldehyde |
250 ppm
|
25
80 |
10 ppm
|
30
30 |
>60
>60* |
| Hydrogen Sulfide |
550 ppm
|
25
80 |
30 ppm
|
30
30 |
>60
>60* |
| Nitrogen Dioxide |
100 ppm
|
25
80 |
1 ppm NO2
|
30
30 |
>60
>60* |
| Phosgene |
125 ppm
|
25
80 |
1.25 ppm
|
30
30 |
>60
>60* |
| Hydrogen Cyanide |
470 ppm
|
25
80 |
10 ppm
|
30
30 |
>60
>60* |
| Phosphine |
150 ppm
|
25
80 |
0.5 ppm
|
30
30 |
>60
>60* |
| HD† Mustard Agent |
50 mg/m3 vapor & 25 drops liquid
|
Breathing Pump 40 lpm
|
0.6 mg/m3 ct 6.0 mg/min/3
|
60
|
>60* Min
|
| GB† Sarin |
210 mg/m3
|
Breathing Pump 40 lpm
|
0.087 mg/m3
|
60
|
>60* min
|
| DOP Dioctyl Phthalate |
160 mg/m3
|
50% RH 85 lpm
|
0.03%
|
Load to 200 mg
|
<0.005%
|
All test conducted at 25°C
*Test was stopped at 60 min
†"SMARTMAN" Test
| Description |
Catalog No.
|
| SCape CBRN 30 |
4057805
|
| Baby SCape Hood |
4057807
|
Downloads
Automatic Blower Actuation - Fool proof operation. Blower automatically starts when hood is removed from case. User only has to put on the hood to be protected.
One Size - Eliminates logistical issues stemming from multiple sizes
No Nosecup or Mouthbit - Eliminates sizing difficulties. Dramatically improves communication - even with telephones, cell phones and other communication devices.
Blower Indicator Light - Allows users (including hearing impaired individuals) to determine that the product is operating.
Comfortable Neck Seal - One size neck seal. Beards/glasses/long hair accommodated easily. Not possible with faceseal mask. Very comfortable.
Clear Hood/Large Visor - Allows user to perform a wide range of tasks including reading, driving, etc. Total facial recognition.
Quiet 64 LPM Blower - Delvers reliable protection with minimal training. Eases physiological burden on user. Reduces claustrophobic feelings associated with other hoods. Aids breathing for those with respiratory issues (eg asthma).
Exhaust Valve - The integral exhaust valve regulates/maintains positive pressure within the hood.
Filter Canister - Military grade canister provides protection against a range of military agents and NIOSH TRAs (filter data). HEPA filter provides biological/radiological/particulate protection.
Sealed Case - Five year shelf life. Eliminates need to perform any operation (eg filter plug removal) after removing product from package.
Automatic Agitation
One Size
30 Minute Certification
Minimal Training Required
Easy to understand instructions