Industries Served
• Industrial |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Home > Respiratory Protection > CDR 4500 NIOSH CBRN Full Face Mask
NEW!-CDR 4500 NIOSH CBRN Approved
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
The Draeger CDR 4500 full face mask was specifically designed for use in civil defense and civil protection. Together with CBRN Cap 1 Canister, the mask provides effective protection against hazardous substances in the ambient air.
The Draeger CDR 4500 full face mask offers and face from harmful gases and particles in the ambient air. The elastomer mask body is extremely resistant to chemicals and mechanical impact. The |
The CDR 4500, combined with our CBRN Cap 1 canister provides proven protection from a wide variety of potentially hazardous situations. The combination has passed rigorous chemical permeation and penetration resistance tests using sarin and mustard gases. The ten gases that the Cap 1 canister has been tested against represent protection from approximately 140 different gases, in addition to the P100 particulate protection. This versatile mask and filter combination represents an important part of the personal protective equipment for emergency response teams.
|
NIOSH CBRN Testing Agents
|
Test Concentration
(ppm) |
Breakthrough (ppm)
|
| Ammonia |
2500
|
12.5
|
| Cyanogen Chloride |
300
|
2
|
| Cyclohexane* |
2600
|
10
|
| Formaldehyde |
500
|
1
|
| Hydrogen Cyanide |
940
|
4.7†
|
| Hydrogen Sulfide |
1000
|
5
|
| Nitrogen Dioxide |
200
|
1 NO or 25 NO2**
|
| Phosgene |
250
|
1.25
|
| Phosphine |
300
|
0.3
|
| Sulfur Dioxide |
1500
|
5
|
*Cyclohexane is representative or organic vapors with a vapor pressure less than or equal to Cyclohexane
†Sum of HCN and C2N2
**Nitrogen Dioxide is monitored for both NO and NO2, determined by which breaks through first
| Mask as a Whole | High chemical resistance according to (US NIOSH CBRN Standard) resistance even against warfare agents |
| Mask Body | Silicone free elastomer |
| Sealing Frame | Double seal with triple sealing line for comfortable, tight fit |
| Lens | Impact proof polycarbonate (PC) with anti scratch coating on both side for high chemical resistance, large field of vision and excellent quality of vision |
| Filter Connection | Standard thread NATO 40 mm |
| Weight | Approximately 500g, without filter |
| Harness | 5 point large adjusting points to prevent trapping of hear |
| Neck Strap | As standard |
| Speech Diaphragm | Stainless steel, high speech quality |
| Resistance | To US CBRN APR standard against sarin and mustard gas for up to 8 hours, test description and test concentration on request |
| Service Life | > 10 years, storage and servicing as per manual |
| Canister | Shelf life minimum 10 years in original package |
| Approvals | US NIOSH CBRN standard, TC-14G-0286 also approved to EN 136 Cl. 3, CE mark |
| Description |
Catalog No.
|
| CDR 4500 black plastic lens frame, Universal Size |
R55440
|
| CDR 4500 black SS lens frame, Size Small |
R55575
|
| CDR 4500 black SS lens frame, Size Medium |
R55710
|
| CDR 4500 black SS lens frame, Size Large |
R55580
|
| CBRN Cap 1 Canister |
6738146
|
| Description |
Catalog No.
|
| Tactical Mask Bag |
4056997
|
| Hard Plastic Case |
4055785
|
| Trispec Spectacle Kit |
4057622
|
| Mask Spectacles Kit |
R51548
|
| Lens Overlay Protectors, pk/25 |
4055092
|
| Hairnet |
4054931
|
| Anti-Fogging Gel |
R52560
|
Downloads