Home > Gas Detection Instruments > Calibration Gas > QC-50 QuickCheck System

QC-50
QuickCheck System

QuickCheck

The QC-50 is a simple yet rugged device allowing quick and easy testing of gas detection systems. The QC-50 uses ACD's patent pending QuickCheck Vial (QCV) technology. These QCV factory sealed vials contain an inner glass ampule with a small amount of the chemical to be tested. For use the QCV is firmly squeezed to break the inner ampule before it is inserted in the QC-50.

Then with a few squeezes of the aspirator bulb a reliable bump test gas is produced. Since the QCV contains such a small amount of chemical it is nonhazardous for shipping, storage and disposal And since the vials are sealed they have a very long shelf life compared to many other bump test methods.

  • Simple to use
  • No batteries
  • No hazardous shipping charges
  • Able to provide a wide variety of gases
  • Extremely cost effective
  • Light weight and easy to carry
  • Rugged and durable

Specifications

Useful Vial Life Up to 8 hours of use
Vial Warranty 1 year
Operating Temperature Nominal @ 20°C
Relative Humidity 0-100%
Dimensions (QC-50) 5 cm x 18.4 cm
Dimensions (QCV) 1.1 cm x 3.4 cm
Weight (QC-50) 2.6 ounces
Weight (QCV) .14 ounces

Please Note: Vial concentration is approximate and is based upon a freshly opened vial at 70°F and 1/4 LPM air flow. Refer to the manual for information on the approximate concentrations at differing temperatures and flow rates. Vial concentration is also depleted with use. Refer to the manual for information on the effect of use on vial concentration.

Before use verify that the filters in vial are blue. If the filters are white the vial no longer contains ammonia. If you suspect a vial has leaked or has an improper seal, Do Not Remove the foil cover. Warranty is voided as soon as the protective cover is removed or broken. Return the vial to ACD for evalutation and potential warranty replacement.

The QuickCheck Series of instruments and vials are not intended to be used for actual calibration of gas detection equipment. The QuickCheck is designed to give a simple test of instrument functionality with the gas type being monitored.

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
QC-50 Kit include belt pack, manual, hose & 6 vials, specify type and concentration
850-1050-00
QC-50 only, vial not included
750-1050-00
Belt Pack carrying Case for QC-50
730-1050-00
Ammonia QCV, pk/12
525-0001-12
Hydrogen Cyanide QCV, pk/12
525-0002-12
Tolune QCV, pk/12
525-0003-12
Hexane QCV, pk/24
525-0004-12
New Products | Air Sampling | Gas Detection | Other Meters | Respiratory | Water Quality | WMD HazMat
Applications | Product Specials | Rentals | Links | Index | Contact Us | Home


AFC International, Inc.
PO Box 894, DeMotte, IN 46310
715 SW Almond St, Ste C, DeMotte, IN 46310
800-952-3293 219-987-6825 Fax 219-987-6826
eMail: sales@afcintl.com

Last Revised: 1/23/07