Detector Tubes - <h1>Colorimetric Gas Detector Tubes</h1>
<h3>Variety</h3>
<p>Short Term tubes are used to measure to concentration of specific contaminants instantaneously. Currently, about 160 short term Draeger tubes are available for determining and measuring more than 350 different gases, vapors and aerosols.</p>
<p>The majority of the short term Draeger Tubes are scaled tubes, operating on a defined sample volume drawn through the tube by performing a specified number of pump strokes. The concentration of the contaminant is read directly from the calibrated scale by assessing the length of the discoloration.</p>
<p>Short term measurements can be made manually with the Accuro gas detector pump or automatically with the battery operated Accuro 2000 or Quantimeter 1000 automatic pumps.</p>
<h3>Aerosols</h3>
<p>Included in the short term tubes are Draeger Tubes for aerosols. Aerosols are not gases or vapors, but liquid or solid particles suspended in air - such as dusts, fumes or mists. Draeger provides aerosol tubes for Arsenic Trioxide, Cyanides, Chromic Acid, Nickel, Oil Mist and Sulfuric Acid.</p>
<h3>Selection</h3>
<p>A tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the following pages. Select the tubes listed according to the chemical hazard to be tested and the measuring range. Order the tube by the catalog number that appears to the left</p>
<p>Note: Measuring range information pertains to air monitoring only. The TLV limits found throughout this catalog were obtained from the ACGIH (Americans Conference of Governmental Industrial Hygienists) 1995-1996 Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices.</p>
<h3>Area of Use</h3>
<ul>
    <li>Measuring concentration at a specific moment (e.g. concentration peaks)
    </li>
    <li>Measuring person related exposure in an inhalation area (e.g. at defined intervals)
    </li>
    <li>Detecting leaks (e.g. in pipelines or gas installations)
    </li>
    <li>Investigating confined space (e.g. canals, tunnels or tanks) </li>
</ul>
<h3>How The System Works</h3>
<p>Simple 4 step operation:</p>
<ol>
    <li>Select the appropriate Draeger Tube for chemical hazard and expected concentration.
    </li>
    <li>Open tube and insert in pump
    </li>
    <li>Pull sample through tube
    </li>
    <li>Read concentration directly from the color band on the scale </li>
</ol>
<p>If the designated air contaminant is present, it reacts with the chemical reagent in the tube, producing a color change. The length or intensity of the color band indicated contaminant levels - the longer or darker the stain, the higher the concentration.</p>
<p><strong>Caution: Interchanging Draeger Pumps and Tubes with other brands may cause erroneous results and should not be done.</strong></p>

Colorimetric Gas Detector Tubes

Variety

Short Term tubes are used to measure to concentration of specific contaminants instantaneously. Currently, about 160 short term Draeger tubes are available for determining and measuring more than 350 different gases, vapors and aerosols.

The majority of the short term Draeger Tubes are scaled tubes, operating on a defined sample volume drawn through the tube by performing a specified number of pump strokes. The concentration of the contaminant is read directly from the calibrated scale by assessing the length of the discoloration.

Short term measurements can be made manually with the Accuro gas detector pump or automatically with the battery operated Accuro 2000 or Quantimeter 1000 automatic pumps.

Aerosols

Included in the short term tubes are Draeger Tubes for aerosols. Aerosols are not gases or vapors, but liquid or solid particles suspended in air - such as dusts, fumes or mists. Draeger provides aerosol tubes for Arsenic Trioxide, Cyanides, Chromic Acid, Nickel, Oil Mist and Sulfuric Acid.

Selection

A tube should be selected to detect each suspected chemical. Simply locate the contaminant listed alphabetically in the following pages. Select the tubes listed according to the chemical hazard to be tested and the measuring range. Order the tube by the catalog number that appears to the left

Note: Measuring range information pertains to air monitoring only. The TLV limits found throughout this catalog were obtained from the ACGIH (Americans Conference of Governmental Industrial Hygienists) 1995-1996 Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices.

Area of Use

  • Measuring concentration at a specific moment (e.g. concentration peaks)
  • Measuring person related exposure in an inhalation area (e.g. at defined intervals)
  • Detecting leaks (e.g. in pipelines or gas installations)
  • Investigating confined space (e.g. canals, tunnels or tanks)

How The System Works

Simple 4 step operation:

  1. Select the appropriate Draeger Tube for chemical hazard and expected concentration.
  2. Open tube and insert in pump
  3. Pull sample through tube
  4. Read concentration directly from the color band on the scale

If the designated air contaminant is present, it reacts with the chemical reagent in the tube, producing a color change. The length or intensity of the color band indicated contaminant levels - the longer or darker the stain, the higher the concentration.

Caution: Interchanging Draeger Pumps and Tubes with other brands may cause erroneous results and should not be done.


Page:1 2  Next Page
Diffusion (Passive Sampling) Tubes from Draeger Safety
Diffusion (Passive Sampling) Tubes from Draeger Safety
Draeger Short Term Detector Tubes: A
Draeger Short Term Detector Tubes: A
Draeger Short Term Detector Tubes: B
Draeger Short Term Detector Tubes: B
Draeger Short Term Detector Tubes: C
Draeger Short Term Detector Tubes: C
Draeger Short Term Detector Tubes: D
Draeger Short Term Detector Tubes: D
Draeger Short Term Detector Tubes: E
Draeger Short Term Detector Tubes: E
Draeger Short Term Detector Tubes: F
Draeger Short Term Detector Tubes: F
Draeger Short Term Detector Tubes: Gasoline
Draeger Short Term Detector Tubes: Gasoline
Draeger Short Term Detector Tubes: H
Draeger Short Term Detector Tubes: H
Draeger Short Term Detector Tubes: I
Draeger Short Term Detector Tubes: I
Draeger Short Term Detector Tubes: M
Draeger Short Term Detector Tubes: M
Draeger Short Term Detector Tubes: N
Draeger Short Term Detector Tubes: N
Draeger Short Term Detector Tubes: O
Draeger Short Term Detector Tubes: O
Draeger Short Term Detector Tubes: P
Draeger Short Term Detector Tubes: P
Draeger Short Term Detector Tubes: S
Draeger Short Term Detector Tubes: S
Draeger Short Term Detector Tubes: T
Draeger Short Term Detector Tubes: T
Draeger Short Term Detector Tubes: Vinyl Chloride
Draeger Short Term Detector Tubes: Vinyl Chloride
Draeger Short Term Detector Tubes: Water Vapor
Draeger Short Term Detector Tubes: Water Vapor
Draeger Short Term Detector Tubes: Xylene
Draeger Short Term Detector Tubes: Xylene
Draeger Short Term Detector Tubes: Zinc Chromate
Draeger Short Term Detector Tubes: Zinc Chromate
Page:1 2  Next Page
 
 

Home | About Us | Our Products | Applications | Repair | Resources | Contact Us | Site Map | Login
Products Categories: New Products | Product Specials | Gas Detection | WMD/Hazmat | Isocynate | Air Sampling | Respiratory | Water Quality | Other Instruments | Rental
Product Industries: Industrial Hygiene | Environmental | Confined Space Entry | Fire/Hazmat | Indoor Air Quality (IAQ) | Water Quality | WMD / Law Enforcement

   Popular Product Searches: Ammonia Gas Detector |  Benzene Gas Detector |  Chlorine Gas Detector |  Combustible Gas Detector |  VOC Gas Detector
   Popular Brand Searches: Analytical Technology |  Bacharach Inc |  Crowcon Detection Instruments |  Draeger Safety |  Environics |  GfG Instrumentation |  Honeywell Analytics | 
Rae Systems |  Sensit Technologies |  Sensor Electronics |  Viasensor

AFC International, Inc.
Tel: 800-952-3293 or 219-987-6825 Fax: 219-987-6826
sales@afcintl.com
715 SW Almond St, Ste C | DeMotte, IN 46310
PO Box 894 | DeMotte, IN 46310

Website Maintained by Evolution Point, LLC.

 

Website maintained by Evolution Point - chicago marketing agency, web development chicago, chicago web development, print design, integrated marketing services chicago, interactive agency, search engine optimization, multilanguage website

Web Analytics