The quality of the breathing air can be tested in accordance to air purity standards (i.e. CGA Grade D or better or DIN 3188) according to ANSI specifications by means of quantitative measurements of the contaminants. Aerotest Simultan HP is suited for examining the quality of air supplied by compressors or compressed air cylinders in the high pressure range.
Measurements can be completed within 5 minutes.
The measuring device is provided with a DIN G 5/8" connection. Adapters CGA 347 (male & female are provided for connection to US standard equipment. All components of the Aerotest Simultan are arranged in a transport case and ready for use.
Specifications
| Medium |
Compressed air |
| Supply Pressure |
Maximum 4500 psi (200/300 bar) |
| Connection |
CGA 347 female connection to cylinder valve, CGA 347 male connection to compressor/filling station, G 5/8" or INT |
| Flow |
0.2 LPM & 4.0 LPM |
Measuring Range
| Tube |
Measuring Range |
| Carbon Monoxide |
2.5-150 ppm
|
| Carbon Dioxide |
100-3,000 ppm
|
| Oil |
0.1-10 mg/m3
|
| Water Vapor |
5-250 mg/m3
|
Ordering Information
The Aerotest Simultan HP Kit, includes a reducer, measuring device for 4 tubes, timer, tube opener, CGA347 male and female connector, instruction, accuro pump, pump spare parts kit, pump manual, case and 1 box of all tubes listed below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
| Description |
Catalog No.
|
| Aerotest Simultan HP Kit |
4055986 |
| Carbon Dioxide 100/a-P Tubes |
6728521 |
| Carbon Monoxide 5/a-P |
6728511 |
| Oil 10/a-P |
6728371 |
| Water Vapor 20/a-P |
6728531 |
Downloads
General Aerotest literature
Aerotest Simultan HP literature
International Breathing Air Standards for Compressed Air
Oil 10/a-P Tube Test Times datasheet
Oil Tube Detection limits datasheet
Dew point conversion table