E-mail this product to a friend
|
Chip Measurement System (CMS) from Draeger Safety
The System
The CMS combines substance specific measuring Chips with an electronic based Analyzer for an easy to use spot-measurement system. The 10 capillaries in each Chip are filled with a reagent system based on Draeger's 60+ years of colorimetric chemistry expertise. The analyzer combines a revolutionary optical system for analyzing the color reaction with a mass flow controller and pump system that provides unbeatable reproducibility.
Fast Response Time
The CMS Analyzer requires no warm-up time. After taking a test, the results can be reported as quickly as 20 seconds. Higher concentrations, which pose a greater hazard, are reported faster than trace background levels. This increases the safety of using the CMS system.TWA and action levels are typically analyzed within 1-2 minutes. After providing the measurement results, the CMS is immediately ready for another test or another Chip for further analysis of the environment.
The expertise of Draeger's worldwide experience in industrial gas measurement has come to focus in the CMS. This is combined with a photo-optical controller that measures the speed of the chemical reaction, thus eliminating the human objectivity. Unlike other systems that rely on the volume of air, the CMS pulls the same mass of air through the capillary every time. The mass flow controller automatically compensates for changes in atmospheric pressure.
Accuracies of ±4 to 7% measured value is achieved for most gases. CMS has been validated by a nationally accredited third party laboratory
Chemical Specific Chips
When you need to know exactly what is there, CMS is the tool to provide you those answers. The chemistry is chosen to provide the best results possible. The capillaries of several chips have multiple levels (Yes, even in something that small!) to help eliminate cross sensitivity or derive a specific measurement of the targeted chemical.
The CMS Chip
The Chip consists of 10 measurement capillaries filled with substance-specific reagent systems. The gas type, part number and batch number are printed on the chip. A printed barcode on the chip, read by the analyzer optics, contains information about gas type, measuring range and measuring time required for completing the measurement. Each chip is calibrated during manufacturing and is valid for two years.
Simplified Operation
The CMS is literally as easy to operate as 1-2-3. Making analysis is as simple as turning the unit "on" (moving the slide position to position 1), then following the plain language instructions on the display to load the Chip and move the slide selector to positions 2 and 3. Operating the CMS could not be easier because this is the exact same procedure for every Chip!Upon completion of analysis, the CMS Analyzer shows the concentration in the display. Any misinterpretation of the results is eliminated by the unambiguous digital display of the concentration.
Simplified Maintenance
The CMS Analyzer does not require gas calibration! All calibration information is stored on the bar code of the CMS Chip and automatically downloaded to the analyzer when inserted. An electronic system self test is performed every time the Analyzer is switched ON, and a sampling system test is performed before each test. You are always assured that the CMS system is operating properly. Operating on alkaline batteries means that there are no worries about charging or battery memory. CMS is gas detection made simple.
Data Recorder
The internal data recorder stores up to fifty measurements with the time/date, contaminant/concentration and the sequential number of the measurement in a series. Measurement location information (in alphabetical code) may be entered manually. The stored data can be recalled and displayed on demand.
Accessories
In order to measure inaccessible areas, the analyzer can be equipped with a remote system which consists of an additional pump and extension hose. The remote system can be installed in the back of the analyzer. Once attached, the remote system is activated by a separate switch and can remain mounted to the analyzer indefinitely. Additionally, a telescopic wand may be used for remote sampling.
A kit for emergency response is now available. It includes an analyzer, remote system, telescopic probe, 10 chips, flashlight/lantern, notepad and a chip case. Note: Chips marked with a (*) are included with this kit.
Specifications
| Size |
8" x 3.6" x 1.7" |
| Weight |
25.6 ounces |
| Ingress Protection |
IP-54, protected against dust and water |
| Data Capacity |
Stores up to 50 measurements |
| Power Supply |
4 x 1.5 Volt (AA) alkaline batteries |
| Battery Duration |
450 minutes of analysis time (typically greater than 100 measurements) |
| Approvals |
UL: Class I, Div 1, Groups A, B, C, D, T4 |
| CSA: Class I, Div 1, Groups A, B, C, D, T4 |
| CENELEC: EEx ib IIC T4 |
| MSHA, permissible gas analyzer |
| Operational Temperature |
32-104°F |
Ordering Information
Each monitor includes calibration adapter, tubing, manual and case. Call for information on the 450 Series with vibrating option. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
| Description |
Catalog No.
|
| CMS Analyzer Set, includes analyzer, allen wrench and batteries |
6405300 |
| CMS Analyzer Set with Remote System |
8317700
|
| Remote System for measurement of inaccessible place, includes 3M of hose with adapter, screwdriver & float probe |
6405060 |
| CMS Emergency Response Kit includes analyzer, remote system, telescopic probe, 10 chips (*) and carrying case |
4055711 |
| CMS Emergency Response Kit without Chips, includes analyzer, remote systems, telescopic probe and carrying case |
4055976 |
| CMS Indoor Air Quality Kit, includes analyzer, batteries, nylon trasnport case and 1 each of Carbon Dioxide, Carbon Monoxide, Formaldehyde and Ozone Chips |
4056455
|
| Telescopic Probe with Viton Sampling Hose, remote system required |
8316530
|
| CMS Sampling Hose with Adapter and Float Probe, remote system required, 3M |
8317614
|
| CMS Sampling Hose with Adapter and Float Probe, remote systems required, 10M |
8317613 |
| CMS Extension Hose Adapter |
8319269
|
| Training Chip |
|
| Soft Side Case for analyzer and chips |
|
| Molded Plastic Transport Case |
|
| CMS Emergency Response Case with foam inserts, holds 14-16 chips |
|
| CMS Handbook |
9092086
|
| CMS Training CD |
4056637
|
Ordering Information - Chips
| Chip |
Measuring Range
|
Catalog No.
|
| Acetic Acid |
2.0-50.0 ppm |
6406330 |
| Acetone |
40.0-600 ppm |
6406470 |
| Ammonia |
0.20-5.0 ppm |
6406550 |
| Ammonia |
2.0-50.0 ppm |
6406130 |
| Ammonia* |
10.0-150 ppm |
6406020 |
| Ammonia |
100-2,000 ppm
|
|
| Benzene |
50 - 2,500 ppb
|
6406600
|
| Benzene(**)* |
0.20-10.0 ppm |
6406030 |
| Benzene(**) |
0.50-10.0 ppm |
6406160 |
| Benzene |
10.0-250 ppm |
6406280 |
| Butadiene |
1.0-25.0 ppm |
6406460 |
| Carbon Dioxide |
200-3,000 ppm |
6406190 |
| Carbon Dioxide* |
1,000-25,000 ppm |
6406070 |
| Carbon Dioxide |
1.0-20% vol |
6406210 |
| Carbon Monoxide* |
5.0-150 ppm |
6406080 |
| Chlorine* |
0.20-10.0 ppm |
6406010 |
| Ethanol |
100-2,500 ppm |
6406370 |
| Ethylene Oxide |
0.40-5.0 ppm
|
6406580
|
| Formaldehyde |
0.20-5.0 ppm |
6406540 |
| Hydrochloric Acid* |
1.0-25.0 ppm |
6406090 |
| Hydrochloric Acid |
20.0-500 ppm |
6406140 |
| Hydrogen Cyanide |
2.0-50.0 ppm |
6406100 |
| Hydrogen Peroxide |
0.20-2.0 ppm |
6406440 |
| Hydrogen Sulfide |
0.20-5.0 ppm |
6406520 |
| Hydrogen Sulfide* |
2.0-50.0 ppm |
6406050 |
| Hydrogen Sulfide |
20.0-500 ppm |
6406150 |
| Hydrogen Sulfide |
100-2,500 ppm |
6406220 |
| Iso-Propanol |
40.0-1,000 ppm |
6406390 |
| Mercaptan |
0.25-6.0 ppm |
6406360 |
| Methanol |
20.0-500 ppm |
6406380 |
| MTBE |
10.0-200 ppm |
6406530 |
| Methylene Chloride |
20.0-400 ppm |
6406510 |
| Nitrogen Dioxide* |
0.50-25.0 ppm |
6406120 |
| Nitrous Fumes* |
0.50-15.0 ppm |
6406060 |
| Nitrous Fumes |
10.0-200 ppm |
6406240 |
| Oxygen |
1.0-30.0% Vol |
6406490 |
| Ozone |
25.0-1,000 ppb |
6406430 |
| Perchloroethylene* |
5.0-500 ppm |
6406040 |
| Petroleum Hydrocarbons |
20.0-500 ppm |
6406200 |
| Petroleum Hydrocarbons |
100-3,000 ppm |
6406270 |
| Phosgene |
0.05-2.0 ppm |
6406340 |
| Phosphine |
0.10-2.5 ppm |
6406400 |
| Phosphine |
1.0-25.0 ppm |
6406410 |
| Phosphine |
20.0-500 ppm |
6406420 |
| Phosphine |
200-5,000 ppm |
6406500 |
| Propane |
100-2,000 ppm |
6406310 |
| Styrene |
2.0-40.0 ppm |
6406560 |
| Sulfur Dioxide |
0.40-10.0 ppm |
6406110 |
| Sulfur Dioxide |
5.0-150 ppm |
6406180 |
| Toluene |
10.0-300 ppm |
6406250 |
| Training Chip |
- |
6406290 |
| Trichloroethylene |
5.0-100 ppm |
6406320 |
| Vinyl Chloride |
0.30-10.0 ppm |
6406170 |
| Vinyl Chloride |
10.0-250 ppm |
6406230 |
| Water Vapor |
0.40-10.0 mg/L |
6406450 |
| Xylene |
10.0-300 ppm |
6406260 |
(**)Please Note: The two Benzene chips in the CMS program have nearly the same measurement range. The primary difference is the humidity limits. The Benzene 0.5-10 ppm chip is designed for high humidity environments. Please refer to the following table.
Maximum Humidity,
Benzene 0.2-10 ppm |
Temperature °F |
Maximum Humidity,
Benzene 0.5-10 ppm |
|
100% |
32 |
100% |
|
100% |
50 |
100% |
|
100% |
68 |
100% |
|
99% |
86 |
100% |
|
76% |
95 |
100% |
|
60% |
104 |
80% |
Performance Data
| Measuring Range & Resolution |
Depends on the chip type |
| Typical Measuring Time |
1-2 minutes in the range of the limit values, dependent on the chip type and the concentration of the hazardous substance |
| Contamination Effects |
Not possible |
| Calibration |
Not necessary |
| Operational Temperature |
34 to 104°F (0 to 40°C) |
| Storage Temperature; Analyzer |
-4 to 140°F (-20 to 60°C) |
| Storage Temperature; Chips |
<77°F (<25°C) |
| Atmospheric Pressure |
700 to 1,100 HpA (or Mbar) |
| Humidity |
0 to 95% relative, not condensed |
| Determination of the Measurement Value |
Optics & light transfer system reflective measurement |
| System Diagnostics |
Self-performing, microprocessor controlled for all components of the system |
| Display |
LCD, 2 x 16 alphanumeric digits with backlight |
| Menu Languages |
English, German, French, Spanish |
| Operational Capacity |
Approximately 450 minutes on one set of batteries |
| Power Source |
4 x 1.5V (AA) alkaline batteries |
| Weight |
1.6 pounds (730g) |
| Dimensions |
8" x 3.6" x 1.7" |
| Approvals |
UL Class 1, Div. 1, Groups A, B, C, D, Temp Code T4 |
| Protection Class |
Dust & water spray protection according to IP54 |
Downloads
CMS Literature
|