Area monitoring without limits - the Draeger X-zone 5000. In combination with the Draeger X-am 5000, the X-zone 5000 reliably monitors for up to six hazardous gases and warns at preset levels. This easily transportable, robust, and waterproof unit extends mobile gas detection technology to a unique system with many application.
The Draeger X-zone 5000 transforms the Draeger X-am 5000 personal gas detection instrument into an innovative area monitoring device for a wide range of applications. A patented combination for increased safety - used with personal gas air monitoring carried on the body or positioned where gas hazards are expected, the X-zone 5000 area monitor knows no limits.
Even from a distance, the illuminated green LED ring indicates that the air is free of toxic and combustible gases. When gas hazards are detected, the LED changes colors from green to red, providing a clear visual warning that hazardous gas is present. In addition, it emits a loud and audible evacuation alarm. With a patented 350° alarm amplifier, the acoustic warning is heard easily over a wide area, independent of wind direction. The Draeger X-zone 5000 gas entry is arranged so that gas can diffuse into the Draeger X-am 5000 from all sides.
Up to 25 X-zones can be automatically interconnected to form a wireless fenceline. This interconnection of the monitoring devices allows for rapid securing of larger areas, e.g. leaking pipelines or industrial tanks - or the monitoring required during industrial shutdowns.
In the event of a gas alarm, the Draeger X-zone 5000 transmits alarm signals to all units that are part of the fenceline which then display a daughter alarm. The original alarming unit shows a red LED along with its audible alarm, while the daughter alarm displays green/red with its illuminated LED ring. This provides fast, easy recognition of the general alarm, which identifying the unit which alarmed originally. This assures a positive alert and a clear and clean evacuation. Alternatively, the fenceline can be wired.
An optional integrated pump allows monitoring allows monitoring of remote areas by pulling a sample to the device. This provides continuous monitoring of confined spaces and locations which are difficult to access - from a distance of up to 150 feet.
Via the potential free alarm contact, the X-zone 5000 can be connected to and operate external equipment such as alarm horns, lamps or traffic lights. In addition, the fenceline signal, along with the alarm contact, can be forwarded to a control room - overseeing a wide range of applications.
Unlike personal gas detectors, area monitoring devices often stay located within a potentially hazardous area, even during a gas alarm. It is therefore important that the devices are approved for use in explosive hazard areas. The approvals for X-zone 5000 enable the continuous operation of the device in an explosive atmosphere and environment.
Two different types of rechargeable batteries enable the X-zone 5000 to be adapted to a variety of applications: the 12 Ah battery unit weight about 15 pounds and offers continuous operation for up to 60 hours. The alternative 24 Ah battery provides up to 120 hours of continuous operation - a complete working week.
The X-zone 5000 can be charged in two ways: in the conventional wired manner or via a modern wireless induction charger. With the inductive charge cradle, the device is simply placed into the charger - alleviating the problems encountered with dirty charging contacts etc. Additionally this non-contact charging possibility also allows maintenance and service to be carried our simultaneously.
With the Draeger CC-Vision PC software, the X-zone 5000 can be configured to meet individual needs and requirements. Alarm volume, visual cadences and frequency all can be adjusted. In addition, X-zones can be grouped to work as teams, so several groups of units can be set up to monitor different areas in close proximity without interfering with each other.
X-zone Specifications
Live Signal
|
Green status display 360°, illuminated ring (LED(
|
| Alarms |
Visual: 360° LED
Audible: >108 dB at 1M, 120 dB at 30 cm
Configurable alarm patterns, frequencies and volume
|
| Temperature |
-4 to 122°F, intermittent + 130°F |
| Pressure |
700 to 1300 hPa, 20.7 to 38.4" Hg |
| Humidity |
10 to 95% Rh |
Ingress Protection
|
IP 67
|
| Operating Time |
About 60 hours (12 Ah battery)
About 120 hours (24 Ah battery)
Dependent upon sensor & configuration of the life signal
|
| Charging Time |
<10 hours
Flexible power supply: External 100-240V charger or inductive wireless charger
|
Pump Operation
|
Maximum hose length is 150 feet
|
Alarm Output
|
Potential free alarm, contact for intrinsically safe circuits (6-pole); <20 V to 0.25A (0.15 constant current); resisting load
|
Radio Transmission
|
Worldwide license free ISM frequencies, digital radio, robust and interference free transmission up to 100M
|
RF Approvals
|
915 MHz
|
| Size |
16.2" x 11.4" x 11.4"
|
| Weight |
15 pounds, 12 Ah battery
22 pounds, 24 Ah battery
|
| Approvals |
ATEX: I M1 Ex ia I MA, II 1G Ex ia IIC T3 Ga, II 2G Ex ia d IIC T4 GB
IEC: Ex ia IIC T3/T4
CSAUL: Ex ia IIC T3, Ex d ia IIC T4, Class I, Zone 0, AEX is IIC T3, Class I, Zone 1, AEx d ia IIC T4
|
X-am 5000 Instrument Specifications
| Battery |
Alkaline, rechargeable NiMH cells for alkaline pack, T4 battery pack |
| Alarms |
Visual: 360°
Audible: multi tone >90 dB at 1 foot
Vibration |
| Temperature |
-4 to 122°F, intermittent + 130°F |
| Pressure |
700 to 1300 hPa, 20.7 to 38.4" Hg |
| Humidity |
10 to 95% Rh |
| Datalogger |
Can be read via infrared about 1000 hours with 5 gases and a recording interval of 1 reading per minute |
| Operating Time |
>12 hours with pulsed mode > 40 hours |
| Charging Time |
<4 hours |
| Size |
1.85" x 5.08" x 1.22" |
| Pump Operation |
Maximum hose length 20 M, 30 hours with 3AA alkaline batteries |
| Weight |
7.8 ounces |
| Approvals |
UL: Class I & II, Div 1, Groups A, B, C, D, E, F, G Temp Code T4/T3
IECEx: Ex ia I, Ex ia IIC T3, Ex d ia I, Ex d ia IIC T4/T3
ATEX: I M1 Ex ia I, II 1G Ex ia IIC T3, I M2 Ex d ia I, II 2G Ex d ia IIC T4/T3
CSA: pending
CE Mark: Electromagnetic compatibility, 89/336/EWG
RoHS: Directive 2002/95/EC |
Ordering Information
For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
| Description |
Catalog No. |
X-zone 5000, Diffusion, 12 Ah Battery
|
8320744 |
X-zone 5000, Diffusion, 24 Ah Battery
|
8320745 |
X-zone 5000, Internal Pump, 12 Ah Battery
|
8320746 |
X-zone 5000, Internal Pump, 24 Ah Battery
|
8320747 |
Gas Supply Adapter
|
8320108
|
Alarm Damper
|
8320110
|
Led Extender, 1 foot high
|
8320645
|
Inductive Charger
|
8320626
|
Plug In Charger
|
8320749
|
CC-Vision Software
|
6408515
|
USB Cable
|
8317409
|
Downloads
X-zone 5000 literature
X-am 5000 literature