AFC International - Specialists in gas detection equipment, WMD / Hazmat equipment, Air sampling instrumentation, respiratory protection equipment and isocyanate detectors for product brands like Draeger and MultiRae Systems.  
 
 


Click here to view larger image


Mail E-mail this product to a friend


previous  up  next 

Fumigation Detector Tube Kit from Draeger

The Draeger Tube measurement system provides an easy method for testing containers and other spaces for the presence of fumigation agents. A specially developed measuring strategy allows for the detection of fumigants eve when the chemical is unknown. The Draeger Fumigation Test Kit can be equipped with all the necessary components for this measurement.

Hazards caused by fumigants - To prevent goods from being damaged by animals such as insects and other disease carriers, containers are flooded with toxic or suffocating gases. Fumigants are highly toxic and harmful to the health in many ways. To ensure adequate protection, the concentration of the fumigants used must be measured. This is relevant for all personnel present during:

  • the start or finish of the fumigation process
  • the opening of transport containers or other confined spaces
  • the loading or unloading of fumigated products from transport containers
  • the removal of fumigated goods from packaging materials
  • transportation (in case of leakages)

Suitable measurement instruments are used to determine the type and concentration of fumigants before opening a container or entering other spaces.

Thereby, it is important to check the Oxygen concentration in the container or other spaces. When inert gases have been used, they will displace Oxygen and this results in a very high probability of suffocation. A leakage in one individual package is one example of a relatively simple cause for this.

Mobile and quick - The well known Draeger Tube measuring method is an easy way to perform measurements. In only a few minutes, the concentration of the fumigants within the container can be determined. Depending on the concentration measured, the decision can be made whether the container or space can be entered or ventilated.

Even when a container has not been declared correctly or the labeling is no longer legible, the Draeger measuring strategy will assist in the identification and detection of the fumigation agents.

Easy to use - For several decades, Draeger Tubes have been renowned for their ease of use and high degree of measurement accuracy. Even without special training, the Draeger Tubes, which were especially developed for this application, provide reliable test results. Draeger Tubes are ready for use at any time. All that is needed are the corresponding tubes, the Draeger Accuro hand pump and the Draeger bar probe. By comparing the color change within the detector tube to the printed scale, an estimation of the concentration can be made.

Recommended measurement strategy - If the fumigant is known, the corresponding Draeger Tube is chosen and the measurement carried out as instructed. If the measurement result is too high, then the container or space should be ventilated. A new measurement should be taken at periodic intervals and when the concentration is low enough, the container or room can be released for entry. If the concentration detected is below the defined maximum limit, the container or room can be opened and entered.

The measurement of fumigants should take place while the container is still closed. To do this, insert the Draeger Bar Probe through the rubber sea of the container door. The probe should be used to lift the rubber seal of the container at its lowest point and pushed as far as possible into the container. The Draeger Tubes should then be prepared for measurement and attached to the bar probe. The necessary pump strokes for the measurement should then be made by using the Draeger gas detection pump.

If the fumigant is not known, the use of the Draeger Simultest Fumigation is recommended to determine which chemical has been used. This test set allows for the measurement of five typical fumigation agents at the same time.

  • Ammonia or Ethylene Oxide
  • Methyl Bromide
  • Hydrocyanic Acid
  • Phosphine
  • Formaldehyde

In addition, the following Draeger Tubes should be used for the measurement of Ethylene Oxide, carbon Dioxide and Sulfuryl Fluoride:

  • Ethylene Oxide 1/a, 1 to 15 ppm
  • Carbon Dioxide 0.1%/a, 0.1 to 1.2 vol %
  • Sulfuryl Fluoride 1/a, 1 to 5 ppm

When one or more gases are present, the container or space should be ventilated with air before entry and individual Draeger Tubes used to test the concentration of the corresponding gases periodically.

Measuring Range

Tube
Measuring Range
Ammonia
5 - 700 ppm
Benzene
0.5 - 10 ppm
Carbon Dioxide
0.1 - 6 Vol %
Carbon Monoxide 10 - 3,000 ppm
Chloropicrine 0.1 - 2 ppm
1,2-Dichloroethane 2 - 10 ppm
1,3-Dichlorpropene 0.1 - 10 ppm
Ethylene Oxide 1 - 15 ppm
Ethyl Formate 20 - 500 ppm
Formaldehyde 0.2 - 5 ppm
Hydrocyanic Acid 2 - 30 ppm
Methyl Bromide  0.2 - 8 ppm
MITC  0.1 - 6 ppm
Oxygen 5 - 23 Vol %
Phosphine 0.01 - 1 ppm or 0.1 - 4 ppm
Sulfuyl Fluoride 1 - 5 ppm
Toluene 5 - 300 ppm

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Fumigation Case, Empty
8317147
Accuro Hand Pump
6400000
Bar Probe 400
8317188
Extension Hose for Accuro, 1M
6400561
Adapter for Simultest, cutter holder and adapter 6400090
Spart Parts for Accuro 6400220
Ammonia Detector Tube CH20501
Benzene Detector Tube 8101841
Carbon Dioxide Detector Tube CH23501
Carbon Monoxide Detector Tube 8103321
Chloropicrine Detector Tube 8103421
1,2-Dichloroethane Detector Tube 8103391
1,3-Dichloropropene Detector Tube 8103551
Ethylene Oxide Detector Tube 6728961
Ethyl Formate Detector Tube 8103541
Formaldehyde Detector Tube 6733081
Hydrocyanic Acid Detector Tube CH25701
Methyl Bromide Detector Tube 8103391
MITC Detector Tube 8103485
Oxygen Detector Tube 8103261
Phosphine Detector Tube, 0.01 - 1 ppm 8101611
Phosphine Detector Tube, 0.1 - 4 ppm CH31101
Sulfuryl Fluoride Detector Tube 8103471
Tolune Detector Tube 8101661
Simultest Tube, Formaldehyde, Phosphine, Hydrocyanic Acid, Methyl Bromide, Ammonia 8103410
Simultest Tube, Formaldehyde, Phosphine, Hydrocyanic Acid, Methyl Bromide, Ethylene Oxide 8103380

Downloads

 Fumigation Detector Tube literature




 

Related Products


Draeger Short Term Detector Tubes: A
Draeger Short Term Detector Tubes: A
Accuro Hand Pumps from Draeger Safety
Accuro Hand Pumps from Draeger Safety
Half Face Respirator X-plore 3300/3500 from Draeger Safety
Half Face Respirator X-plore 3300/3500 from Draeger Safety
Half Face Respirator X-Plore 2100 from Draeger Safety
Half Face Respirator X-Plore 2100 from Draeger Safety

Other Recommended Products


NEW!! - X-act 5000 Automatic Tube Pump for Draeger Tubes
NEW!! - X-act 5000 Automatic Tube Pump for Draeger Tubes
 
     
 
 

Home | About Us | Our Products | Applications | Repair | Resources | Contact Us | Site Map | Login
Products Categories: New Products | Product Specials | Gas Detection | WMD/Hazmat | Isocynate | Air Sampling | Respiratory | Water Quality | Other Instruments | Rental
Product Industries: Industrial Hygiene | Environmental | Confined Space Entry | Fire/Hazmat | Indoor Air Quality (IAQ) | Water Quality | WMD / Law Enforcement

   Popular Product Searches: Ammonia Gas Detector |  Benzene Gas Detector |  Chlorine Gas Detector |  Combustible Gas Detector |  VOC Gas Detector
   Popular Brand Searches: Analytical Technology |  Bacharach Inc |  Crowcon Detection Instruments |  Draeger Safety |  Environics |  GfG Instrumentation |  Honeywell Analytics | 
Rae Systems |  Sensit Technologies |  Sensor Electronics |  Viasensor

AFC International, Inc.
Tel: 800-952-3293 or 219-987-6825 Fax: 219-987-6826
sales@afcintl.com
715 SW Almond St, Ste C | DeMotte, IN 46310
PO Box 894 | DeMotte, IN 46310

Website Maintained by Evolution Point, LLC.

 

Website maintained by Evolution Point - chicago marketing agency, web development chicago, chicago web development, print design, integrated marketing services chicago, interactive agency, search engine optimization, multilanguage website

Web Analytics