The ChemLogic Single Point Continuous Monitor provides field proven ChemLogic Technology for the quick detection of low level toxic and corrosive gases.
The ChemLogic is the next generation of interference free, low maintenance colorimetric gas detection. This system is simple to install and utilizes ¼" tubing to allow the sample to be drawn up to 150 feet. This monitor also includes relay and analog outputs.
Features
- New intelligent optics
- Optimized flow system
- 2 month cassette
- SD memory card
- Real time display
- Complete front access
- Touch control
- Compact size
- Remote reset
- Tape saver mode
Benefits
- Reduced maintenance and risk of false alarms
- Faster response
- Reduced operating costs
- Field proven reliability
- Easily retrievable data
- Quick real time information
- Easy to service
- Easy to start up and operate
- Simple to install
- Ideal for process application
- Reduces tape usage during high concentrations
Instrument Specifications
| Sample Distance |
150 feet, ¼" ID Teflon FEP Tubing, does not apply to TDI/MDI |
| Exhaust Tubing |
25', ¼" OD, 3/16" ID |
| Display |
HMI |
| Local Alarm Indication |
Visual HMI display |
| Relay Outputs |
7A Form C, programmable Low & High Level, Fault |
| Power |
Less than 2 Amps |
| Enclosure |
NEMA 4X |
| Analog Output |
4-20 mA, 500 ohm max impedance |
| Operating Temperature |
40 to 104°F |
| Operating Voltage |
85-264VAC 50/60 Hz |
| Dimensions |
12.5" x 10.3" x 9" |
| Weight |
30 pounds |
Cassette Ordering Information
For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
| Gas |
Range
|
Cassette Part No.
|
| Acetic Acid |
0-50 ppb
|
1-490-020
|
| Arsine |
0-50, 0-500 ppb
|
1-300-020
|
| Boron Triflouride |
0-5,000 ppb
|
1-400-020
|
| Chlorine |
0-5,000 ppb
|
1-500-020
|
| Diborane |
0-500 ppb
|
1-300-020
|
| Germane |
0-2,000 ppb
|
1-300-020
|
| HDI |
0-100 ppb
|
1-600-020
|
| Hydrogen Bromide |
0-20 ppm
|
1-400-020
|
| Hydrogen Chloride |
0-15 ppm
|
1-400-020
|
| Hydrogen Fluoride |
0-10 ppm
|
1-400-020
|
| Hydrogen Selenide |
0-500 ppb
|
1-300-020
|
| Hydrogen Sulfide |
0-90, 0-500, 0-1,500 ppb, 0-20 ppm |
1-300-020 |
| IPDI |
0-100 ppb
|
1-600-020
|
| MDI |
0-100, 0-200 ppb
|
1-600-020
|
| Phosphine |
0-1,500 ppb
|
1-300-020
|
| Phosgene |
0-300, 0-900, 0-3,000 ppb |
1-400-020 |
| Silane |
0-50 ppm |
1-300-020 |
| TDI |
0-100, 0-200 ppb
|
1-600-020
|
| Velcorin |
0-200 ppb
|
1-200-040
|
Instrument Ordering Information
| Instrument |
Kit Instrument Part No. |
| ChemLogic Monitor, specify curve below, each unit includes 2 adjustable gas alarm level contacts, 1 system fault alarm contact, 4-20 mA output |
2-600-001
|
| H2S, Hydrides Curve, 0-90, 0-500, 0-1,500 ppb & 0-20 ppm |
2-600-101
|
| Low Level Arsine/Hydrogen Selenide Curve |
2-600-106
|
| Hydrides Curve for Arsine, Phosphine, Diborane or Silane |
2-600-107
|
| Mineral Acid Curve for HCl, HG & BF3 |
2-600-102
|
| Phosgene Curve, 0-300, 0-900, 0-3,000 ppb |
2-600-103
|
| Diisocyanates Curve, 0-200 ppb |
2-600-105
|
| Velcorin Curve |
2-600-109
|
| Chlorine Curve |
2-600-108
|
| Acetic Acid Curve |
2-600-110 |