AFC International - Specialists in gas detection equipment, WMD / Hazmat equipment, Air sampling instrumentation, respiratory protection equipment and isocyanate detectors for product brands like Draeger and MultiRae Systems.  
 
 


Click here to view larger image


Mail E-mail this product to a friend


previous  up  next 

ChemKey TLD Isocyanate Detector

The ChemKey™ TLD Toxic Gas Monitor provides a reliable solution for both emergency response and fixed area gas detection in a cost effective manner.

Utilizing the exclusive ChemKey™ Gas Selection System, a single monitor is capable of monitoring over 50 different gases with just a change of ChemKey™ and Chemcassette®.

As with all Chemcassette® based products, you are assured of fast, sensitive and substance specific exposure protection. There is never any danger of false alarms or inaccurate results caused by other commonly present chemicals.

Advantages

  • Portable, flexible and interference free toxic gas detection
  • Battery operated or line powered
  • Exclusive Chemcassette detection is gas specific, sensitivity to ppb levels with physical evidence
  • Low maintenance and no dynamic gas calibration
  • Variety of signals outputs to meet monitoring needs
  • Over 50 gases available, ChemKey allows switching target gases easily

Applications

  • Emergency response teams
  • R&D projects
  • Temporary facility monitoring
  • Industrial hygiene surveys
  • Spill remediation
  • Equipment maintenance crews

Option Available

  • Strip chart recorder

Instrument Specifications

Detection Technique Chemcassette Detection System
Alarm Point ChemKey Gas Selection System provides multiple alarm set points
Response Time As fast as 10 seconds
Alarm Indication Local audio/visual alarms
Signal Outputs SPDT concentration alarm relays, SPDT fault relay; 4-20 mA; digital display
Operating Temperature 32 to 104°F
Power Requirements Rechargeable sealed leak acid chargers at 115VAC
Dimensions 6.5" H x 8" W x 7" D
Weight 9 pounds

What is a Chemcassette™?

Chemcassette™ is the unique trademarked name for a calibration free toxic gas detection method that uses an optical scanning system to detect the presence of gas by a color change on the specially chemically impregnated paper tape. Chemcassette™ technology is highly specific and reacts extremely fast to the presence of parts per billion (ppb) levels of many hazardous gases. Over 200,000 points of gas detection gas currently maintained by the Chemcassette™ sensing technology at any given time around the world in some of the most critical safety applications possible.

What support do I get when I buy a unique Chemcassette™ product?

Each Chemcassette™ is manufactured to traceable ISO 9000 manufacturing standards by a world class team of highly trained chemists and each batch is calibrated with ultra pure gas that is traceable to nationally accepted standards. This means that the end user does not have to provide calibration facilities themselves thereby saving cost and reducing risks to their own staff. Efficient high volume manufacturing techniques means that there is always available Chemcassette™ in stock that can be shipped anywhere so that each customer is never left without adequate safety cover.

What statistics prove the benefits of Chemcassette™ technology?

Honeywell Analytics has been manufacturing their Chemcassette™ sensor tapes for over 25 years and maintain traceable records on every production batch, every calibration and every instrument and calibration gas cylinder used to perform the calibration. Experienced scientists maintain a constant measurement environment when performing the calibrations and they are skilled at handling the very toxic gases used for testing and have double checks in place to confirm that the test gas is still within acceptable specification.

ChemKey Specifications

Chemcassette
Range
Alarms
ChemKey
Part No.
Cassette
Part No.
Amines
Ammonia*
2.6-75.0 ppm
25 ppm
870596-1
706042
50 ppm
870596-2
706042
Ammonia*
2.6-75.0 ppm
25 ppm
870550-1
706042
50 ppm
870550-2
706042
Trimethylamine
1.1-30.0 ppm
10 ppm
870594-1
706002
20 ppm
870594-2
706002
n-Butylamine
0.4-12 ppm
5.0 ppm
870682-1
706042
10 ppm
870682-2
706042
Methylene Dianiline
3-60 ppb
20 ppb
930011-6
709528
40 ppb
930011-4
709528
p-Phenylene Diamine
2-60 ppb
20 ppb
870676-1
709528
40 ppb
870676-2
709528
Toluene Diamine
4-60 ppb
20 ppb
870691-1
709528
40 ppb
870691-2
709528
Diisocyanates
CHDI
2-60 ppb
5 ppb
870553-1
700506
20 ppb
870553-2
700506
HDI
2-60 ppb
5 ppb
870554-1
700506
20 ppb
870554-2
700506
HMDI
2-60 ppb
5 ppb
870555-1
700506
10 ppb
930016-1
700506
20 ppb
870555-2
700506
IPDI
2-60 ppb
5 ppb
870556-1
700506
20 ppb
870556-2
700506
IEM
2-60 ppb
5 ppb
870679-1
700506
20 ppb
870679-2
700506
MDI
2-60 ppb
5 ppb
870557-1
700506
10 ppb
870997
700506
20 ppb
870557-2
700506
MDI-I
2-60 ppb
5 ppb
870593-1
700506
20 ppb
870593-2
700506
NDI
2-60 ppb
5 ppb
870558-1
700506
20 ppb
870558-2
700506
PPDI*
2-60 ppb
5 ppb
870559-1
700506
20 ppb
870559-2
700506
TDI
2-60 ppb
5 ppb
870560-1
700506
10 ppb
870998
700506
20 ppb
870560-2
700506
TMDI
2-60 ppb
5 ppb
870561-1
700506
20 ppb
870561-2
700506
XDI
2-60 ppb
5 ppb
870584-1
700506
20 ppb
870584-2
700506
Hydrazines
MMH
2-400 ppb
5 ppb
1971-0036
708013
10 ppb
1971-0035
708013
20 ppb
1971-0071
708013
200 ppb
870562-1
708013
400 ppb
870562-2
708013
N2H4
20-300 ppb
10 ppb
1971-0072
708013
20 ppb
1971-0070
708013
100 ppb
870563-1
708013
200 ppb
870563-2
708013
UDMH
10-1,000 ppn
10 ppb
870599-1
708013
20 ppb
870599-2
708013
500 ppb
870564-1
708013
1000 ppb
870564-2
708013
Hydrides
Arsine*
50-100 ppb
50 ppb
870565-1
705502
100 ppb
870565-2
705502
Diborane*
>100-200 ppb
100 ppb
870566-1
705502
200 ppb
870556-2
705502
Disilane*
>5-10 ppm
5 ppm
870567-1
705502
10 ppm
870567-2
705502
Germane*
141-600 ppb
200 ppb
870568-1
705502
400 ppb
870568-2
705502
Hydrogen* Selenide
50-100 ppb
50 ppb
870569-1
705502
100 ppb
870569-2
705502
Phosphine*
100-600 pp
100 ppb
870570-3
705502
200 ppb
870570-4
705502
300 ppb
870570-1
705502
600 ppb
870570-2
705502
Silane*
0.5-15 ppm
5 ppm
870571-1
705502
10 ppm
870571-2
705502
Stibine*
100-200 ppb
100 ppb
870572-1
705502
200 ppb
870572-2
705502
tert-Butylarsine*
50-100 ppb
50 ppb
870595-1
705502
100 ppb
870595-2
705502
tert-Butyl-phosphine*
300-600 ppb
300 ppb
870976-1
705502
600 ppb
870976-2
705502
Hydrogen Cyanide
20 ppm
20 ppm
>870573-3
704510
Hydrogen Sulfide*
3 - 50 ppb, 10-20 ppm
10 ppm
870574-1
701012
20 ppm
870574-2
701012
3 ppb
930005-8
701012
10 ppb
930005-10
701012
30 ppb
930005-6
701012
50 ppb
930005-12
701012
Mineral Acids
Hydrogen Bromide
3-6 ppm
3 ppm
870575-1
705505
6 ppm
870575-2
705505
Hydrogen Chloride*
5-10 ppm
5 ppm
870576-1
705505
10 ppm
870576-2
705505
Hydrogen Fluoride
3-6 ppm
3 ppm
870577-1<
705505
6ppm 870577-2
705505
Nitric Acid
2-4 ppm
2 ppm
870578-1
705505
4 ppm
870578-2
705505
Sulfuric Acid
250-500 ppb
250 ppb
870579-1
705505
500 ppb
870579-2
705505
Oxidizers
Bromine*
100-200 ppb
100 ppb
870551-1
711314
200 ppb
870551-2
711314
Chlorine*
0.5-1.0 ppm
0.5 ppm
870597-1
704007
1.0 ppm
870597-2
704007
Chlorine Dioxide*
100-200 ppb
100 ppb
870587-1
704006
200 ppb
870587-2
704006
Fluorine*
0.1-2 ppm
1.0 ppm
1971-0146
1750-9306
2.0 ppm
1971-0147
1750-9306
0.1 ppm
1971-0148
1750-9306
0.2 ppm
1971-0149
1750-9306
Hydrogen Peroxide*
1-2 ppm
1 ppm
870585-1
700278
2 ppm
870585-2
700278
Nitrogen Dioxide*
1-6 ppm
1.0 ppm
870977
703012
2 ppm
930004-4
703012
3 ppm
870580-1
703012
5 ppm
870996
703012
6 ppm
870580-2
703012
Ozone
100-200 ppb
100 ppb
870581-1
704514
200 ppb
870581-2
704514
Phosgene*
100-200 ppb
100 ppb
870582-1
702020
200 ppb
870582-2
702020
Sulfur Dioxide
2-4 ppm
2.0 ppm
870583-1
705015
4 ppm
870583-2
705015

*Note: 30-90 day cassettes available.

Ordering Information

Each TLD includes calibration for one gas, battery charger and ChemCassette Tape. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Instrument
Instrument Part No.
TLD, 115 VAC, 50/60 hz
870500

Downloads

TLD literature

 Chemcassette literature




 

Related Products


Full Face Respirator X-plore 5500 from Draeger Safety
Full Face Respirator X-plore 5500 from Draeger Safety
PAS Colt SAR Personal Airline Respirator from Draeger Safety
PAS Colt SAR Personal Airline Respirator from Draeger Safety
SafeAir Direct Read Colorimetric Badges from Morphix Technologies
SafeAir Direct Read Colorimetric Badges from Morphix Technologies
IsoSense Detector for TDI & MDI from DOD
IsoSense Detector for TDI & MDI from DOD

 
 

Home | About Us | Our Products | Applications | Repair | Resources | Contact Us | Site Map | Login
Products Categories: New Products | Product Specials | Gas Detection | WMD/Hazmat | Isocynate | Air Sampling | Respiratory | Water Quality | Other Instruments | Rental
Product Industries: Industrial Hygiene | Environmental | Confined Space Entry | Fire/Hazmat | Indoor Air Quality (IAQ) | Water Quality | WMD / Law Enforcement

   Popular Product Searches: Ammonia Gas Detector |  Benzene Gas Detector |  Chlorine Gas Detector |  Combustible Gas Detector |  VOC Gas Detector
   Popular Brand Searches: Analytical Technology |  Bacharach Inc |  Crowcon Detection Instruments |  Draeger Safety |  Environics |  GfG Instrumentation |  Honeywell Analytics | 
Rae Systems |  Sensit Technologies |  Sensor Electronics |  Viasensor

AFC International, Inc.
Tel: 800-952-3293 or 219-987-6825 Fax: 219-987-6826
sales@afcintl.com
715 SW Almond St, Ste C | DeMotte, IN 46310
PO Box 894 | DeMotte, IN 46310

Website Maintained by Evolution Point, LLC.

 

Website maintained by Evolution Point - chicago marketing agency, web development chicago, chicago web development, print design, integrated marketing services chicago, interactive agency, search engine optimization, multilanguage website

Web Analytics