E-mail this product to a friend
|
Draeger PSS BG-4 Plus Long Duration Closed Circuit Breathing Apparatus
Specially designed for demanding tasks: the Draeger PSS BG4 Plus closed circuit breathing apparatus combines uncompromising safety with outstanding respiratory protection and wearer comfort. Innovative in design, it provides the wearer with up to four hours of breathing air in toxic environments.
- Breathing air for up to 4 hours
- Highest breathing comfort and an integrated cooling system
- Ergonomically shaped carrying plate
- Reduced exposure from a well balanced system
- Improved harness and intelligent breathing hose routing for excellent freedom of movement
- New Draeger FPS 7000 RP full face mask with integrated drinking valve
Whenever emergency teams are saving lives or extinguishing fires, above or below the ground the Draeger PSS BG 4 Plus comes into its own. Whether used during rescue or fire fighting missions in mines, tunnels or underground train ducts, or in assignments with long access routes, the closed circuit breathing apparatus is the first choice. More than 25,00 professional users rely on the Draeger PSS BG 4 worldwide.
Numerous improvements and new accessories and further improved the ease of servicing. The modifications are available individually or a practical retrofit set upon request.
The slight positive pressure breathing circuit protects the wearer by preventing hazardous substances from entering the sealed breathing system. Depending on the applications, the duration of use is up to four hours. A CO2 absorber removes carbon dioxide from the exhaled air. At the same time the breathing air is enriched with oxygen from the oxygen cylinder. Before the regenerated breathing air is inhaled again it flows through the breathing air cooler.
Both the minimum valve, which enriches the breathing air with additional oxygen upon demand and its attachment clip have been treated with a special coating to protect against corrosion. A redesigned clip simplifies the fitting of the valve. The area around the pressure reducer has been reinforced and additional reinforcement protects the carrying plate, providing greater stability when handling the unit complete with oxygen cylinder. To reduce the temperature of the inhaled air and minimize physical stress to the wearer, the breathing air cooler can be filled with ice.
Newly developed heat protection for the breathing hose and housing are also optionally available to further reduce the temperature of the inhaled air. A T-piece with water trap can be retrofitted to the facemask to prevent water from collecting in the flow are of the device. Any liquid discharged into the breathing circuit from the drain valve is optionally collected in a super absorbent fleece. The fleece is designed for single use and is easily disposed.
Simple CO2 disposal complete with integral dust filter, the flow sensitive CO2 absorber is available as either a single use absorber or refillable cartridge. Fitted with a newly designed spring clip, the CO2 absorber offers increased spring durability. The position and size of the breathing hose connectors have also been optimized for easier handling during assembly. For hygienic storage the single use absorbers are available in a sealed bag.
The ergonomically shaped carrying plate, the low weight and the proven harness with adjustable shoulder straps and easy to use "pull forward" design provide more freedom of movement with less effort. The practical breathing hose routing across the shoulders ensures optimum balance on the wearer's back.
The data captured by the Draeger Sentinel II electronic monitoring unit can be transmitted to the Draeger Merlin telemetry boards. This electronic monitoring and communications system displays Sentinel II data for each of the wearers who are logged on. As a result, entry control personnel are able to view the current status of each of the device wearers and can respond immediately to an emergency.
The Draeger PSS BG 4 Plus is equipped with the Draeger BodyGuard II fully electronic signal and warning unit. Controlled via larger push buttons, it combines a multitude of functions. During use it quickly provides the wearer with important information, thereby reducing the risk potential. Using battery warning thresholds the Draeger BodyGuard II reliably indicates current operational status.
Monitoring Functions
- Cylinder pressure (analog & digital)
- Remaining duration of use (time remaining unit residual pressure warning)
- Temperature indication upon the press of a button
- Automatic recording of all mission data
Optical and Acoustic Warning Signals
- Residual pressure warning
- Two additional selectable electronic alarm thresholds
- Automatic alarm for lack of movement
- Manual emergency call alarm
Dragersorb 400 has been specially designed for the absorption of CO2 in closed circuit breathing apparatus which significantly contributes to long term performance capabilities, especially under the likely conditions of use for the Draeger PSS BG 4 Plus.
Both retrofittable vibration protection and the robustly designed locking hinge increase the safety of the Draeger PSS BG 4 Plus during transportation. For maximum operational readiness, the Draeger PSS BG 4 Plus has been designed to allow the fast assembly and/or removal of device components without special tools.
The full face mask Draeger FPS 7000 ideally complements the Draeger Panorama Nova product family. With an improved head harness and available in various sizes, it adjusts perfectly to every face shape. With its dual sealing line, the almost natural field of view and easy to operate wiper, guarantees a safe tight fit and good all round visibility. An optional adapter enables the connection to the comfortable CamelBak drinking system. Liquid only flows through the straw when the integrated biting valve is pressed together with teeth.
Specifications
Duration of Use
|
4 hours according to EN 145 & NIOSH
|
| Weight, Ready to Use |
34.17 pounds, includes mask, full oxygen cylinder, CO2 absorber & cooling ice |
| Constant Oxygen Metering (LPM O2) |
1.5 to 1.9 |
| Minimum Valve (LPM O2) |
>80 |
| Breathing Bag Volume (L) |
5.5 |
| Bypass Valve (LPM) |
>50 |
| Operating Temperature |
1-40 to 194°F |
| Dimensions |
23.43 x 17.72 x 7.28" |
| Approvals |
EN 145, ex protection to EN 50020, Eex IIC T4, Eex ial & NIOSH |
Ordering Information
For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
| Description |
Catalog No. |
| Draeger PSS BG-4 Plus, 4 Hour Positive Pressure Closed Circuit Breathing Apparatus with Sentinel II |
4057380 |
| Draeger PSS BG-4 Plus, 4 Hour Positive Pressure Closed Circuit Breathing Apparatus with Sentinel II, complete with mask, LW carbon cylinder & valve and black Pelican case |
4057227 |
| Draeger PSS BG-4 Plus, 4 Hour Positive Pressure Closed Circuit Breathing Apparatus with Sentinel II, complete with FPS 7000 Hydration Mask, LW carbon cylinder & valve and black Pelican case |
4057227 |
Accessory Ordering Information
| Description |
Catalog No. |
| Carrying Case, Black Pelican Case with Wheels |
4055237 |
| Carrying Case, Black Pelican Case with Wheels installed |
4056530 |
| Carrying Case, Soft Sided |
4055879 |
| Carrying Case, Soft Sided Installed |
4056531 |
| Upgrade Kit |
R34681 |
| Locking Cooler |
R34710 |
| Black Nomex Hairnet |
4057102 |
| DraegerSorb 400, 20 Kg |
6737985 |
| Filtermats, pk/50 |
4058167 |
| Wooden Strainer for DraegerSorb |
R32618 |
| Refill Kit includes reusable canister, wooden edged strainer, filtermats and fill stand |
4055807 |
| Single Use, Soda Lime Canister |
R34360 |
| Single Use, Soda Lime Canister, Installed |
4056534 |
| Reusable Canister |
R34367
|
| Fill Stand for Reusable Canister |
R33752 |
| Metal Ice Freezing Container |
R33999 |
| Heavy Duty Polyurethane Ice Freezing Container |
4056449 |
| Metal Ice Freezing Container |
R33999 |
| Carbon Fiber Cylinder with Valve & Gauge, 3000 psi |
B30229 |
| Rubber Monitron Display Cover |
R34250 |
| Heat Absorbent Pad |
4056596 |
| BG-4 By-Pass Kit |
4056704 |
| Metal Plate for Reusable Canister |
R34306 |
| Harness System |
R34255 |
| Anti-Vibration Strap |
R34238 |
| Label Kit, front & side |
R34266 |
| Sentinal Upgrade Kit |
4057792 |
Mask Ordering Information
| Description |
Catalog No. |
| FPS 7000 Full Face Respirator with Hydration, Small |
R58135 |
| FPS 7000 Full Face Respirator with Hydration, Medium |
R56670 |
| FPS 7000 Full Face Respirator with Hydration, Large |
R58136 |
| FPS 7000 Full Face Respirator, Small |
R57675 |
| FPS 7000 Full Face Respirator, Medium |
R56326 |
| FPS 7000 Full Face Respirator, Large |
R57676 |
| FPS Communication Savox MS-Com |
R35025 |
| Bracket for MS-Com |
R56846 |
| Mask Comm Connector for mask with hydration |
R56982 |
| Mask Comm Connector |
R56981 |
| Panorama Nova Full Face Respirator, EPDM |
R53306 |
| Panorama Nova Full Face Respirator, Silcone |
R53316 |
| Panorama Nova Full Face Respirator, EPDM Installed |
4056532 |
| Panorama Nova Full Face Respirator, Silicone |
R53316
|
| Panorama Nova Full Face Respirator, Silicone Installed |
4056533 |
BG Comm for Panorama Nova Masks Ordering Information
| Description |
Catalog No. |
| BG Comm Radio Interface Amplifier Adapter Bracket |
4056764 |
| BG Comm M45 Amplifier |
4056798 |
| BG Comm Radio Interface & M45 Amplifier Adapter installed of Panorama Nova, Order Radio Connection Separately |
4056766 |
| Earspeaker Push to Talk |
4056200 |
| Earspeaker Bracket Kit |
4056201 |
| Earspeaker to Mask Screw, Large |
4056212 |
| Motorola Radio Connection, HT1000, JT1000, MT2000, MTS2000, MTX, MTX838, MTX2000, MTX8000, MTX9000, Transcrypt Stealth, GP 900, XTS3000, XTS3500, XTS5000 |
4056218 |
| Motorola Radio Connection, Radius GP300, P1225, GTX, P110, SP10/50, SP21, LTS2000, LTS2000, Sprint-II, GP88 |
4056219 |
| Motorola Radio Connection, Saber, Astro, MX1000 - Hardwired to Radio Connector |
4056220 |
| Motorola Radio Connection, GP350 Hard Wired to Radio Connector |
4056223 |
| Motorola Radio Connection, Expo, Radius P10, P50, HT10 |
4056226 |
| Motorola Radio Connection, HT50, HT90, GT440, Radius P100 |
4056227 |
| Motorola Radio Connection, MX3000/310/320/340/350/360 |
4056228 |
| Motorola Radio Connection, MT500 |
4056230 |
| Motorola Radio Connection, Sprint-Pro |
4056231
|
| Motorola Radio Connection, HT750, HT1250, HT1550, GP328 - Hardwired to radio connector |
4056232 |
| Motorola Radio Connection, HT750, HT1250, GT1550 - Quick disconnect to radio |
4056233 |
| Motorola Radio Connection, MPA, MPD, MTL, TPX |
4056235 |
| Motorola Radio Connection, PCS |
4056236 |
Kenwood Radio Connection, TK220/240/249/260/270/320/340/
350/353/360/430/TH21/25A/41/45/75/91A |
4056237 |
| Kenwood Radio Connection, TK230/330 |
4056238 |
| Kenwood Radio Connection, TK280/380/290/390/480/481/190,2150 |
4056239 |
| ICOM Radio Connection, IC-2A/AT/E, ICH-2/6/12/16, ICU-2/6/12/16 |
4056241 |
| ICOM Radio Connection, F10, F20, IC-F4G-2 |
4056242 |
| ICOM Radio Connection, IC-F30/40/30LT/40LT, F3GS |
4056243 |
| Maxon Radio Connection, SP-2000, SP-2550, SP-2850, SL-70W |
4056244 |
| Maxon Radio Connection, SP-5000 Series, CP-0500 |
4056245 |
| Maxon Radio Connection, PC-50 |
4056246 |
| Midland Radio Connection, 70-153 |
4056247 |
| Midland Radio Connection, 70-165/166/265/266 |
4056248 |
| Midland Radio Connection, 70-145/154/245/254 |
4056249 |
| Midland Radio Connection, 70-195/295 |
4056250 |
| Relm Radio Connection, MPS, MPV08, MPU08B |
4056251 |
| Riton/Jocbom Radio Connection, JBX151, JMX100/400 Series, RTX 150/450, SST Series |
4056252 |
| Standard Radio Connection, HX381/482/580T/581T/582T/585T/587T |
4056253 |
| Standard Radio Connection, HX240U/V |
4056254 |
| Standard Radio Connection, HX320 |
4056255 |
| Tekk Radio Connection, T20, T40, T50, T60 |
4056256 |
| Uniden Radio Connection, SPH/SPU Series, SPU 454 |
4056257 |
| Uniden Radio Connection, SPS310T/320TS |
4056258 |
| Yaesu-Vertex Radio Connection, FT416/816/11R/41R/FTH2005, 2008, 2009, 7005, 7008, 7009 |
4056259 |
| Yaesu-Vertex Radio Connection, VX10, VX300, VX400 Series, F10/40/50 |
4056260 |
| Yaesu-Vertex Radio Connection, FTH2070 |
4056261 |
| Yaesu-Vertex Radio Connection, VX500 |
4056262 |
| Yaesu-Vertex Radio Connection, FT76 |
4056263 |
| Tait Orca Radio Connection, Excel |
4056945 |
BG4 Test Equipment Ordering Information
| Description |
Catalog No. |
| RZ-50e BG-4 Tester includes BG-4 Mask Leak Test Kit |
4056732 |
| Test-It 6100 CCBA Test Kit |
AG02690 |
| Test Accessories Kit for BG-4 |
R33777 |
| Mask Leak Test Kit for BG-4 includes BG Mask Test Adapter, flat jaw clamp, test bladder, rubber squeeze bulb, instructions, pouch |
4056567 |
| Quaester 5000 CCBA/SCBA Dynamic Test Device |
R58317 |
| Adapter, Leak Test for BG Mask |
4055874 |
| PortaCount Fit Test Adapter Kit |
4056767 |
Downloads
BG-4 literature
|