AFC International - Specialists in gas detection equipment, WMD / Hazmat equipment, Air sampling instrumentation, respiratory protection equipment and isocyanate detectors for product brands like Draeger and MultiRae Systems.  
 
 


Click here to view larger image


Mail E-mail this product to a friend


previous  up  next 

CEL-430 Integrating Sound Level Meter with Memory from Casella USA

The CEL-430 integrating sound level meter is a new design that encompasses many of the benefits of the existing CEL-450 and CEL-490 products in a simple and easy to use meter. All DSP technology ensures that the whole of the audio range of noise levels are covered by a single dynamic span. This eliminates the need to change ranges during a measurement and ensures that all the noise captured faithfully and included in the overall result. All the most popular noise units are simultaneously calculated during the measurement and can be read off the large display or recorded for later download to the optional software package.

PC Software

The CEL-430.A meters are available with the optional dB30 dedicated Windows package download and control software. Record the measurements as normal and they will be stored in the meter's memory for later transfer to the computer for printing. The dB30 software also allows the meter to be reconfigured, labeled and stored to suit new measurement requirements. These user defined setups will be ready to go when the meter is next used. A real time output is available for viewing the noise readings on a PC.

Applications

  • Short term hand held measurements
  • Workplace noise assessments
  • Community noise measurements
  • Noise nuisances monitoring
  • Vehicle noise certification
  • Simple survey meter for front line measurements
  • Noise mapping around machines in the workplace
  • Product noise testing
  • Compliance measurements to local noise ordinances
  • Real time output to personal computer

Benefits

  • Single 120 dB dynamic range covers all noise levels
  • Simple easy to use operation
  • Pre configured setups for the most popular measurements
  • Available with ANSI/IEC type 1 and type 2 accuracy
  • Automatic recognition of calibrator when applied to microphone
  • Large custom LCD with automatic backlight
  • Memory for result storage
  • PC software program for archiving and printing results
  • Meter can be remotely configured for special measurements from dB30 PC software
  • Fixed microphone and preamplifier for simplicity

Specifications

Broadband Measured Parameters Instantaneous level, Lxy, maximum level Lxymx, minimum level Lxymn, peak level Lxpk, average level (Q=3) Lxeq, average level (Q=4) Lavg, average level (Q=5) Lavg, takmaximal levels Ltm3 & Ltm6, exposure level LxE
Acoustic Accuracy ANSI S1.4 (R1997) type 1 & type 2, ANSI S1.43, IEC 61672:2002, IEC 60651:1994, IEC 60804:2000
Broadband Frequency Weightings 'A', 'C' and 'Z' (linear, un-weighted, all pass level) simultaneously
Frequency Response (Hz) 6.3 Hz to 30 kHz for -3 dB down points
Time Weightings (Response) Slow and Fast for rms
Peak Frequency Weighting 'A', 'C' or 'Z' separate from rms weighting
Dynamic Range for Display 120 dB
Noise Floor (dB) 16.5 'A' weighted, 19.7 'C', 23.4 'Z' weighted
Maximum Noise Level (dB) 140 dB rms, 143 dB peak
Resolution (dB) 0.1 dB across whole measurement range
DSP Sampling Rate (Hz) 72.30 0 Hz sampling with true rms. values calculated digitally
Memory Storage Capability 100 complete runs each with the overall values of all parameters selected in the setup (maximum of 9 per run plus start date & time)
Storage Methods Manually controlled by user via keypad Start & Stop keys
Duration for Measurement Variable up to 24 hours maximum per run controlled by user
Calibration Method Automatic detection of calibrator on microphone for both 1 kHz & 240 Hz frequency operation. Meter set to user pre entered calibrator dB level, date, time and level of selected calibration is stored in meter
Configurations Saved in Memory 3 factory defaults plus 2 user configured setups using optional dB30 software
Analog Outputs AC signal 0.5 V rms at 98 dB with 22 komega impedance (plus optional log DC output 0 to 2 V for 0 to 140 dB at 14.28 mV/dB)
Digital Output Download of stored data to PC or remote control of operation of meter via dB30 software via RS-232 port at 19200 baud maximum
Keypad Control 6 individual keys with auto backlight operation on key press
Screen Languages for Display English, French, German, Italian, Spanish menu selectable
LCD Screen Display 128 x 64 pixel monochrome backlight display with icon indicators can show up to 9 parameters simultaneously on screen using up/down scroll keys
Battery 4 AA alkaline cells, 15 hours typical life or 12 VDC at 150 mA nominal via 2.1 mm power connector
Dimensions 13.4" x 4" x 1.5"
Weight 19.3 ounces

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Description
Catalog No.
Broadband, ANSI Type 1
CEL-430.A1
Broadband, ANSI Type 2
CEL-430.A2
ANSI Class 1 Acoustic Calibrator & Microphone Adapter
CEL-110/1
ANSI Class 2 Acoustic Calibrator & Microphone Adaptor
CEL-110/2
Complete CEL-430, ANSI Type 1 Kit includes meter, calibrator, software, cable, windscreen, & case
CEL-430.A1/K2
Complete CEL-430, ANSI Type 2 Kit includes meter, calibrator, software, cable, windscreen & case
CEL-430.A2/K2

Downloads

CEL-430 Literature




 

Related Products


CEL-350 dBadge Micro Noise Dosimeter from Casella USA
CEL-350 dBadge Micro Noise Dosimeter from Casella USA
CEL-320 & CEL-320S Series Noise Dosimeter from Casella USA
CEL-320 & CEL-320S Series Noise Dosimeter from Casella USA
CEL-620 Integrating Real Time Analyzer from Casella USA
CEL-620 Integrating Real Time Analyzer from Casella USA
 

 
 

Home | About Us | Our Products | Applications | Repair | Resources | Contact Us | Site Map | Login
Products Categories: New Products | Product Specials | Gas Detection | WMD/Hazmat | Isocynate | Air Sampling | Respiratory | Water Quality | Other Instruments | Rental
Product Industries: Industrial Hygiene | Environmental | Confined Space Entry | Fire/Hazmat | Indoor Air Quality (IAQ) | Water Quality | WMD / Law Enforcement

AFC International, Inc.
Tel: 800-952-3293 or 219-987-6825 Fax: 219-987-6826
sales@afcintl.com
715 SW Almond St, Ste C | DeMotte, IN 46310
PO Box 894 | DeMotte, IN 46310

Website Maintained by Evolution Point, LLC.

 

Website maintained by Evolution Point - chicago marketing agency, web development chicago, chicago web development, print design, integrated marketing services chicago, interactive agency, search engine optimization, multilanguage website

Web Analytics