AFC International - Specialists in gas detection equipment, WMD / Hazmat equipment, Air sampling instrumentation, respiratory protection equipment and isocyanate detectors for product brands like Draeger and MultiRae Systems.  
 
 


Click here to view larger image


Mail E-mail this product to a friend


previous  up  next 

UltraRae 3000 Benzene Specific Monitor from Rae Systems

The UltraRae 3000 is the most advanced Benzene Specific Monitor on the market. Its photoionization detector's (PID) extended range of 0.05 to 10,000 ppm in VOC mode and 50 ppb to 200 ppm in benzene specific mode makes it an ideal instrument for application from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down stream monitoring.

  • Dual detection mode for total benzene exposure assessment: 60 second snap shot or 15 minute STEL measurement
  • High sensitivity to benzene (down to 50 ppb) providing a lower detection range for potentially lower future benzene exposure limits
  • Lower risk of false alarms through advanced speciation method producing benzene readings you can trust
  • Total VOC measurement mode with extended range of 0.05 to 10,000 ppm

Features

Superior Performance

  • Proven PID technology
  • 3 second response in VOC mode or 60 seconds in compound specific mode
  • Extended range up to 10,000 ppm (in VOC mode) with improved linearity
  • Humidity compensation with built in humidity sensor
  • Automatic temperature controlled sampling time calculation
  • Detectors benzene down to 50 ppb (0.05 ppm)
  • Unique 15 minute benzene STEL calculation with 15 minute real time benzene specific measurement
  • Highly specific readings, combining a 9.8 eV UV lamp and Rae-Sep benzene tube
  • New sampling probe design provides instant tube breakthrough visibility

Extremely Versatile

  • VOC mode or benzene specific mode for extreme versatility
  • Real time wireless data transmission with built in BlueTooth and optional RAELink3 portable modem
  • Integrated Rae Systems Correction Factors list for more than 200 compounds, measuring more compounds than any other PID
  • Field interchangeable battery pack is replaceable in seconds without tools

Easy to Use

  • Large graphic display
  • Multi language support
  • Easy access to lamp and sensor in seconds without tools

Low Cost of Ownership

  • Inexpensive analysis using low cost Rae-Sep tubes versus gas detection tubes
  • Much less expensive than a portable GC and no annual factory calibration required

Applications

  • Confined space entry pre screening during refinery and plant maintenance
  • Hazardous material response
  • Marine spill response
  • Refinery down stream monitoring

Specifications

Detector Photo ionization detector with standard 9.8 eV or optional 10.6 eV or 11.7 eV lamps
Battery Rechargeable, external field replaceable lithium ion battery pack and alkaline battery adapter
Operating Hours 16 hours continuous operation
Display 4 lines, 28 x 43 mm
Keypad 1 operation key & 2 programing keys, 1 flashlight on/off button
Direct Readout VOCs as ppm by volume
High and low values
STEL and TWA
Battery and shutdown voltage
Date, time temperature
Alarm 95 dB buzzer and flashing red LED to indicate exceeded preset limits
High: 3 beeps and flashes per second
Low: 2 beeps and flashes per second
STEL and TWA: 1 beep and flash per second
Alarms latching with manual override or automatic reset
Additional diagnostic alarm and display message for low battery and pump stall
EMI/RFI Highly resistant to EMI/RFI. Compliant with EMC directive (2004/108/EC); R&TTE directive (1999/5/EC)
IP Rating IP-65, unit running
Datalogging Standard 6 months at 1 minute intervals
Calibration 2 point or 3 point calibration for zero and span. Calibration memory for 8 calibration gases, alarm limits, span values and calibration dates
Communication Download data and upload instrument setup from PC through charging cradle
Wireless data transmission through built in BlueTooth
Frequency for RaeLink3 Optional Modem 902 to 928 MHz (License free), 2.400 to 2.4835 GHz (License free), 433 MHz, 869 MHz
RF Range up to 15'/4.5M (2,400 GHz BlueTooth), extendable with RaeLink3 modem to 2 miles (3.2 km)
Low Flow Alarm Auto shut off pump at low flow condition
Sampling Pump Internal, integrated flow rate at 400 cc/min
Sample from 100' horizontally and vertically
Temperature -4 to 113°F
Humidity 0 to 95% rH
Size 10" L x 3" W x 2.5" H
Weight 26 ounces
Approvals UL: Class I, Div I, Group A, B, C, D
ATEX: II 2G EEx ia IIC T4

Sensor Specifications

Gas Monitor
Range
Resolution
Response Time
VOCs
0 to 99.99 ppm
100 too 999.9 ppm
1,000 to 9,999 ppm
0.05 ppm
0.1 ppm
1 ppm
< 3 seconds
Benzene
0 to 200 ppm
0.05 ppm
< 60 seconds
Butadiene
0 to 200 ppm
0.05 ppm
< 60 seconds

Ordering Information

The UltraRae 3000 Benzene Specific Monitor includes specified PID lamp and tubes, wireless communication module built in, datalogger, ProRae Studio Package, travel charger, Flex-I-Probe and short probe, external filter, red rubber boot, alkaline battery adapter, lamp cleaning kit, tool kit, Li-Ion battery and charger, operation CD-Rom, manual and soft leather case. The UltraRae Accessory Kit includes all of the above items plus a hard transport case, charging/download cradle, metal filters and o-rings, organic vapor zeroing kit, gas outlet port adapter and tubing. The Calibration Kit includes calibration gas and regulator. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
UltraRae Kit for Benzene includes Accessory Kit and Calibration Gas
059-D311-200
UltraRae Monitor Only for Benzene
059-D310-000
UltraRae Kit for Butadiene includes Accessory Kit
059-D410-200
UltraRae for Butadiene
059-D410-000

Accessory Ordering Information

Description
Catalog No.
Rae-Sep Benzene Tube, pk/5, requires 9.8 eV Lamp
012-3022-005
Rae-Sep Halocarbon Tubes, pk/5, requires 11.7 eV Lamp
012-3023-005
Rae-Sep Butadiene Tubes, pk/5, requires 9.8 eV Lamp
012-3024-005
Rae-Sep VOC Tubes, pk/5
012-2502-005
Lamp Cleaning Kit
081-0002-000

Downloads

Table of Ionization Potentials

What is a Photo Ionization Detector?

PIDs as a HazMat Response Tool

PIDs as an Arson Response Tool

Guide to Atmospheric Testing in a Confined Space

Weapons of Mass Destruction

PIDs in Clandestine Laboratories Application

Assessment of Exposure Risk in an Unknown Environment

UltraRae 3000 Compound Specific Gas Detection Instrument literature




 

Related Products


ppbRae 3000 ppb PID VOC Detector from Rae Systems
ppbRae 3000 ppb PID VOC Detector from Rae Systems
MultiRae Plus - One to Five Gas Monitor With VOC Detection from Rae Systems
MultiRae Plus - One to Five Gas Monitor With VOC Detection from Rae Systems
RaeLink3 Wireless Modem with Integrated GPS
RaeLink3 Wireless Modem with Integrated GPS
MiniRae Lite Portable PID VOC Monitor from Rae Systems
MiniRae Lite Portable PID VOC Monitor from Rae Systems

Other Recommended Products


Chip Measurement System (CMS) from Draeger Safety
Chip Measurement System (CMS) from Draeger Safety
 
Autofim and Autofim II GC Flame Ionization Detectors (FID)
Autofim and Autofim II GC Flame Ionization Detectors (FID)
 
   
 
 

Home | About Us | Our Products | Applications | Repair | Resources | Contact Us | Site Map | Login
Products Categories: New Products | Product Specials | Gas Detection | WMD/Hazmat | Isocynate | Air Sampling | Respiratory | Water Quality | Other Instruments | Rental
Product Industries: Industrial Hygiene | Environmental | Confined Space Entry | Fire/Hazmat | Indoor Air Quality (IAQ) | Water Quality | WMD / Law Enforcement

AFC International, Inc.
Tel: 800-952-3293 or 219-987-6825 Fax: 219-987-6826
sales@afcintl.com
715 SW Almond St, Ste C | DeMotte, IN 46310
PO Box 894 | DeMotte, IN 46310

Website Maintained by Evolution Point, LLC.

 