The AreaRae is a one to five sensor gas detector equipped with a wireless RF (radio frequency) modem which allows the unit to communicate and transmit readings and other information on a real time basis with a remotely located base controller.
In stand alone operation, the AreaRae is a rugged, weather resistant, portable monitor that can run over 18 hours on rechargeable lithium ion batteries. It is also the first "lunch box" type multi sensor instrument able to include a photo ionization detector (PID) for parts per million measurement of volatile organic compounds (VOCs), as well as LEL, oxygen and up to two electrochemical toxic sensors for measurement of specific toxic substances such a carbon monoxide and hydrogen sulfide.
The RF modem allows real time data transmissions with a base controller located up to 2 miles away from the AreaRae detector. A personal computer can be used as the base station for an AreaRae system. The standard ProRae remote software used to control AreaRae systems is capable of monitoring the input of up to 64 remotely located monitors.
AreaRae options include the ability to track and display readings from remotely located detectors on a GPS map.
The AreaRae is ideal for hazmat and other emergency response monitoring programs. AreaRae detectors can be used to quickly establish an emergency perimeter by setting out multiple monitors at strategic locations, then backing off to a position of safety to monitor readings over the wireless link.
The AreaRae is available individually or as part of the Rapid Deployment Kit (RDK) system package.
Features
- Up to five sensors (PID, LEL, oxygen and two toxic gas eletrochemical)
- Loud buzzer and large, extra bright warning light
- Large LCD display and keypad
- Rugged, weather resistant stainless housing
- Built in sampling pump
- Interchangeable lithium ion or alkaline battery pack
- Continuous operation via AC source
- Real time wireless data transmission with built in RF modem
- View real time sensor data and alarm status at headquarters or command center
- ProRae Remote software simultaneously controls and displays readings for up to 64 remote detectors
- License free, ISM wireless transmittion with communication range up to 2 miles extendable with RaeLink repeaters
- Optional wall mounting bracket or field mounting tripod adapter
- Optional GPS provides ability to track and display readings from remote detectors
Applications
- HazMat and emergency response
- Refineries and petrochemical plants
- Confined space entry
- Power plants
- Pump and paper industry
- Plant and mill turnarounds
- Marine and offshore wells
Sensor Specifications
| Sensor |
Range |
Resolution |
| Oxygen |
0-30% |
0.1% |
| Combustible Gas |
1-100% LEL |
1% |
| VOCs |
0-199 ppm |
0.1 ppm |
|
200-2,000 ppm |
1 ppm |
| Carbon Monoxide |
0-500 ppm |
1 ppm |
|
10-2,000 ppm
|
10 ppm
|
| Hydrogen Sulfide |
0-100 ppm |
1 ppm |
| Sulfur Dioxide |
0-20.0 ppm |
0.1 ppm |
| Nitric Oxide |
0-250 ppm |
1 ppm |
| Nitrogen Dioxide |
0-20.0 ppm |
0.1 ppm |
| Chlorine |
0-10.0 ppm |
0.1 ppm |
| Hydrogen Cyanide |
0-100 ppm |
1 ppm |
| Ammonia |
0-50 ppm |
1 ppm |
| Phosphine |
0-5.0 ppm |
0.1 ppm |
| Hydrogen Chloride |
2 to 15 ppm
|
1 ppm
|
| Hydrogen Fluoride |
2 to 10 ppm
|
1 ppm
|
Specifications
| Detector |
Up to 5 sensors (oxygen, combustible, two toxic and VOC) electrochemical sensors for toxic gases and oxygen, PID sensor for VOCs, catalytic sensors for combustible gases. |
| Operating Hours |
Up to 18 hours continuous operation |
| Battery |
Rechargeable, 7.4V/4.5 Ah, Lithium-Ion battery pack with built in charger or a 6 C cell alkaline battery pack |
| Battery Charger |
Less than 10 hours charge thorough built-in smart charger |
| Display |
2 line, 16 digit LCD with automatic LED back light in dim light |
| Keypads |
3 operation and 4 programming keys |
| Direct Readout |
Instantaneous values, sensor name, high and low values for all sensors, TWA and STEL values for toxic and VOCs, battery voltage and elapsed time |
| Alarm |
Flashing red LED cluster to indicate exceeded preset limits, low battery or alarm failure |
| Alarm Setting |
Separate alarm limit settings for TWA, STEL, Low and High alarms |
| Alarm Mode |
Latching or automatic reset |
| Audible Alarm |
110 dB buzzer at 10 cm (typical) |
| Visual Alarm |
Flashing red LED cluster |
| Datalogging |
4,000 points for each sensor with time stamp, serial number, user ID, site ID |
| Data Storage |
20,000 readings (64 hours, 5 channels at 1 minute intervals) in non volatile memory |
| Datalog Interval |
Programmable 1-3,600 seconds |
| Communication |
Upload data to PC and Download monitor setup from PC through RS-232 link to serial port on PC |
| EM Immunity |
No effect when exposed to 0.43 mW/cm2 RF interference (5 watt transmitter at 12") |
| Calibration |
Two point field calibration for fresh air and standard reference gas |
| Sampling Pump |
Internal integrated diaphragm pump with programmable "High" (400CC) and "Low" (300cc) flow rate settings |
| Low Flow Alarm |
Auto shut off at low flow condition |
| Temperature |
-4 to 113°F |
| Humidity |
0 to 95% rH |
| Size |
9.25" x 5.0" x 9.25" |
| Weight |
8.5 pounds |
| Optional |
Integrate GPS receiver |
| Approvals |
UL & CSA: Class 1, Division II, Groups A, B, C, D |
| Frequency |
902 to 928 MHz (License free) |
| RF Range |
Up to 2 miles (900 MHz) extendable with RaeLink Repeaters |
Ordering Information
Each AreaRae includes sensors as specified, filters, calibration adapter, manual, shoulder strap, rechargeable Li-Ion battery pack & charger, alkaline battery pack, water trap adapter, 10 spare external water trap filters, hard transport case, Teflon tubing, and tool kit.. The AreaRae with calibration kit includes all of the above plus calibration gas and regulator. The datalogger version includes software and cable. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Downloads
Table of Ionization Potentials
What is a Photo Ionization Detector?
PID Training Outline
Correction Factors, Ionization Energies and Calibration Characteristics
PIDs as a HazMat Response Tool
PIDs as an Arson Response Tool
Guide to Atmospheric Testing in a Confined Space
Using PIDs in Terrorist Chemical Attacks
PIDs in Clandestine Laboratories Applications
PIDs for Continuous Monitoring of VOCs
Using PIDs for Indoor Air Quality Surveys
Environmental Applications for PIDS
Using PIDs for Assessment of Exposure Risk in Unknown Environments
Understanding AreaRae Options
Use of AreaRaes for Fenceline Monitoring
Facility and Venue Protection
AreaRaes for Incident Response and Law Enforcement
Nerve Agent Measurement by PID
Sharing AreaRae Assets
Decontamination Procedures for Monitors Exposed to Chemical Warfare Agents
Basics of Wireless Security
Sensor Specifications and Cross Sensitivies
AreaRae DatasheetP>