E-mail this product to a friend
|
MultiRae Plus - One to Five Gas Monitor With VOC Detection from Rae Systems
The MultiRae Plus combines a PID (Photo Ionization Detector) with the standard four gases of a confined space monitor (O2, LEL and two toxic gas sensors) in one compact monitor with sampling pump. The MultiRae Plus gets the job done in more circumstances than any other gas detector. With more than 10,000 units in the field today, its versatility makes it the gas meter of choice for some of the highest profile HazMat/WMD teams in the USA. The MultiRae Plus is quickly and easily changed from a sophisticated technician instrument to a simple text only monitor. The same monitor can be used as a personal monitor, a hand held sniffer or as a continuous operation area monitor.
Features
- O2, LEL PID and any two plug in "smart" toxic sensors: CO H2S, SO2, NO, NO2, Cl2, HCN, NH3, PH3
- 0-2,000 ppm measurement of VOCs with 0.1 ppm resolution
- Measure more chemicals than with any other PID. With over 60 correction factors built into the MultiRae Plus memory and the largest printed list of correction factors in the world (300+), Rae Systems offers the ability to accurately measure more ionizable chemicals than any other PID!
- Drop in battery - when work schedules require putting in more than 14 hours supplied by the advanced Lithium-ion battery, the drop in alkaline pack supplied with every MultiRae Plus allows you to finish the job.
- User friendly screens make it easy to use for simple applications and flexible enough for sophisticated options.
- Rugged rubber boot assures that the MultiRae Plus survives the bumps and knocks of tough field use.
- Strong, built-in sample pump draws up to 100 feet horizontally or vertically. Large external filter and automatic low flowage.
- Large keys are operable with 3 layers of gloves
- Easy to read display with backlit
- Store up to 80 hours of data at one minute intervals for all 5 sensors for download to PC (with the optional datalogging)
- Loud audible alarm that varies for different alarm conditions and an optional external vibration alarm for noisy areas.
- Access sensors and battery in seconds with the new, improved case.
Applications
- Initial PPE (personal protective equipment) assessment
- Leak detection
- Perimeter establishment and maintenance
- Spill delineation
- Decontamination
- Remediation
- Homeland Security
- Confined Space Entry
- IAQ
- Aviation/wing tank entry with jet fuel
- Shipyard and maritime confined spaces with diesel fuel
- Leaking underground storage tanks
- Pulp and paper industry for confined space entry in turpentine environments
- Soil and water headspace analysis
- Landfill monitoring
Instrument Specifications
| Detector |
Protected catalytic bead for combustible gases |
| Interchangeable electrochemical sensors for oxygen and toxic gases |
| Photo ionization detector for VOCs, 10.6 eV lamp standard |
| Battery |
Interchangeable Li-ion and alkaline battery packs, rechargeable units include Li-ion battery pack with internal smart charging, 120V AC/DC wall adapter and spare alkaline battery pack |
| Operating Hours |
14 hours continuous, unit will run and charge simultaneously |
| Display |
2 line, 16 digit LCD with LED back light automatically in dim light or alarm condition |
| Key Pads |
1 operation key and 2 programming keys |
| Attachment |
Durable yellow boot with belt clip and wrist strap |
| Direct Readout |
Instantaneous values: Oxygen as % by vol, Combustible gas as % of lower explosion limit (LEL), Toxic gases and VOCs as parts per million by volume |
| High and low values for all gases |
| STEL & TWA values of toxic gases and VOCs |
| Battery and shut down voltage |
| Date, time, elapsed time, temperature, LEL/VOC scale |
| Alarms |
90 dB buzzer and flashing red LED to indicate exceeded preset limits: High - 3 beeps and flashes per second, Low - 2 beeps and flashes per second, STEL & TWA - 1 beep and flash per second |
| Automatic reset or latching with manual override |
| Additional diagnostic alarm and display message for low battery and pump stall |
| Calibration |
Two point field calibration for zero and standard reference gas |
| Datalogging |
80 hours, 5 channels at one minute intervals download to PC with serial number of unit, user ID, site number and calibration gas |
| EM/RFI |
Highly resistant to EMI/RFI, compliant with EMC Directive 89/336/EEC |
| IP Rating |
IP-55 protected against dust, protected against low pressure jets of water from all directions. |
| Sampling Pump |
Internal pump, Low: flow rate 150 cc/min, High: 250 cc/min |
| Low Flow Alarm |
Auto shut off pump at low flow condition |
| Temperature |
-4° to 113°F |
| Humidity |
0 to 95% relative humidity (non-condensing) |
| Intrinsic Safety |
UL & cUL Class I, Division I, Group A, B, C, D, T3C, EEX ia IIC T3, T4 |
| Size |
4.65" L x 3" W x 1.9" H |
| Weight |
16 ounces |
Sensor Specifications
| Sensor |
Range |
Resolution |
Response Time |
| Oxygen |
0-30% |
0.1% |
15 seconds |
| Combustible Gas |
0-100% LEL |
1% |
15 seconds |
| VOCs |
0-200 ppm |
0.1 ppm |
10 seconds |
|
200-2,000 ppm |
1 ppm |
10 seconds |
| Carbon Monoxide |
0-500 ppm |
1 ppm |
20 seconds |
| Hydrogen Sulfide |
0-100 ppm |
1 ppm |
30 seconds |
| Sulfur Dioxide |
0-20 ppm |
0.1 ppm |
15 seconds |
| Nitric Oxide |
0-250 ppm |
1 ppm |
20 seconds |
| Nitrogen Dioxide |
0-20 ppm |
0.1 ppm |
25 seconds |
| Chlorine |
0-10 ppm |
0.1 ppm |
60 seconds |
| Hydrogen Cyanide |
0-100 ppm |
1 ppm |
60 seconds |
| Ammonia |
0-50 ppm |
1 ppm |
150 seconds |
| Phosphine |
0-5 ppm |
0.1 ppm |
60 seconds |
The SensorRae is available for the MultiRae Plus. The SensorRae is a four socket electrochemical sensor conditioning station. It keeps Rae Systems' sensors warmed up and ready for immediate use when they are not installed in a Rae Systems EC product.
Ordering Information
Each instrument includes specified sensors, filters, calibration adapter, training CD-Rom, manual, rubber boot, alkaline battery adapter, Li-ion battery & charger, datalogger, software, cable and inlet probe. The Accessory Kit includes a hard transport case, sampling wand with 15' of self coiling Teflon tubing and tool kit. The Calibration Kit includes calibration gas and regulators. Each MultiRae Plus is wireless enabled and certified. A black rubber boot is available for tactical operations. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
| Description |
Catalog No. |
| MultiRae Plus with LEL, Oxygen, Carbon Monoxide & Hydrogen Sulfide Sensors, 10.6 eV PID Lamp, Pump and Datalogger |
009-3121-010 |
| MultiRae Plus with LEL, Oxygen, Carbon Monoxide & Hydrogen Sulfide Sensors, 10.6 eV PID Lamp, Pump, Datalogger and Accessory Kit |
009-3121-013 |
| MultiRae Plus with LEL, Oxygen, Carbon Monoxide & Hydrogen Sulfide Sensors, 10.6 eV PID Lamp, Pump, Datalogger, Accessory Kit and Calibration Kit |
009-3121-014 |
| Black Rubber Boot |
027-3042-000
|
Other sensor combinations available, please contact AFC for details.
Downloads
Table of Ionization Potentials
What is a Photo Ionization Detector?
PID Training Outline
Electrohemical Sensor Replacement & Maintenance
PIDs as a HazMat Response Tool
PIDs as an Arson Response Tool
Guide to Atmospheric Testing in a Confined Space
Using PIDs in Terrorist Chemical Attacks
PIDs in Clandestine Laboratories Applications
PIDs for Continuous Monitoring of VOCs
Using PIDs for Indoor Air Quality Surveys
Environmental Applications for PIDS
Using PIDs for Assessment of Exposure Risk in Unknown Environments
Facility and Venue Protection
Nerve Agent Measurement by PID
Decontamination Procedures for Monitors Exposed to Chemical Warfare Agents
Basics of Wireless Security
MultiRae literature
SensorRae literature
|