E-mail this product to a friend
|
Draeger Safety X-am 5000 Multi Gas Detector
The X-am 5000 is smallest gas detection instrument for up to 5 gases. The Draeger X-am 5000 belongs to a new generation of gas detectors, developed specifically for personal monitoring as well as oxygen and harmful concentrations of CO, H2S, CO2, Cl2, HCN, NH3, NO2, PH3, H2, NO and SO2. A variety of special calibrations for the catalytic Ex sensor allow even more sensitivity when detecting specific combustible gases and vapors. Equipped with durable XXS sensor technology, the Draeger X-am 5000 offers maximum security and extremely low operational costs.
Ergonomic mobile phone design - Despite its advanced functionality, the Draeger X-am 5000's practical, mobile phone design and light weight make it comfortable for users to carry. Reduced to its essentials, the two button control panel and easy to follow menu system allow for intuitive use.
Durable electrochemical sensor technology - Equipped with durable XXS sensor technology, the Draeger X-am 5000 offers maximum security at extremely low operational costs. The longevity of the catalytic sensor and an optional five year warranty for the oxygen, hydrogen sulfide and carbon monoxide sensors are unique to the market.
Flexible and adaptable sensor exchange - It is easy to exchange, upgrade or calibrate the sensors to other gases. The ability to customize the Draeger X-am 5000's sensors makes more applications possible.
Innovative Ex sensor with full range functionality - The catalytic Ex sensor measures 0-100% LEL and 0-100 Vol % methane concentration. The calibration concept simplifies a calibration to vapors. When set for maximum sensitivity, the detector is even more reliable to warn about unknown hazards.
Robust and waterproof - The Draeger X-am 5000 is tough: water and dust resistant according to IP67, the detector remains fully functional even after falling into water. The integrated rubber protection and shock proof sensors ensure additional resistance to impact and vibration. Moreover, the Draeger X-am 5000 is insensitive to electromagnetic interference.
External pump - The optional external pump, which operates with a flexible hose up to 20M long, makes it possible to use the detector for pre-entry measurements for tanks, shafts, etc. The pump starts automatically when the detector is inserted.
Optimum solutions for function (bump) tests and calibrations - Simple, fast and professional form a function (bump) test to complete documentation, user can choose from a range of practical, on site solutions that offer maximum safety for every application. The Draeger E-Cal automatic test and calibration station and the Draeger Bump Test Station are ideal system extensions that save time and reduce workload.
Calibration options - Fresh air, mixed gas and single gas calibrations can be done directly using the Draeger X-am 5000 menu.
Flexible power supply - The Draeger X-am 5000 can be used with either the standard alkaline or rechargeable NiMH batteries. In addition, it can be fitted with a T4 battery that can be charged while still inside the instrument. An optional Save Energy Mode makes it possible to increase the operating time of Draeger X-am 5000 to 48 hours. This is done by selecting a measurement interval of either 1 second, 10 or 20 seconds for the CatEx sensor.
Instrument Specifications
| Battery |
Alkaline, rechargeable NiMH cells for alkaline pack, T4 battery pack |
| Alarms |
Visual: 360°
Audible: multi tone >90 dB at 1 foot
Vibration |
| Temperature |
-4 to 122°F, intermittent + 130°F |
| Pressure |
700 to 1300 hPa, 20.7 to 38.4" Hg |
| Humidity |
10 to 95% Rh |
| Datalogger |
Can be read via infrared about 1000 hours with 5 gases and a recording interval of 1 reading per minute |
| Operating Time |
>12 hours with pulsed mode > 40 hours |
| Charging Time |
<4 hours |
| Size |
1.85" x 5.08" x 1.22" |
| Pump Operation |
Maximum hose length 20 M, 30 hours with 3AA alkaline batteries |
| Weight |
7.8 ounces |
| Approvals |
UL: Class I & II, Div 1, Groups A, B, C, D, E, F, G Temp Code T4/T3
IECEx: Ex ia I, Ex ia IIC T3, Ex d ia I, Ex d ia IIC T4/T3
ATEX: I M1 Ex ia I, II 1G Ex ia IIC T3, I M2 Ex d ia I, II 2G Ex d ia IIC T4/T3
CSA: pending
CE Mark: Electromagnetic compatibility, 89/336/EWG
RoHS: Directive 2002/95/EC |
Sensor Specifications
| Gas |
Range |
Resolution
|
| CO/H2S |
0-2,000 ppm CO
0-200 ppm H2S
|
2 ppm CO
1 ppm H2S
|
| Carbon Monoxide |
0-2,000ppm |
1 ppm
|
| Hydrogen Sulfide |
0-200 ppm |
1 ppm
|
| Oxygen |
0-25 Vol % |
0.1 % Vol
|
| Nitric Oxide |
0-200 ppm |
1 ppm |
| Nitrogen Dioxide |
0-50 ppm |
0.1 ppm |
| Sulfur Dioxide |
0-50 ppm |
0.1 ppm |
| Phosphine |
0-20 ppm |
0.01 ppm |
| Phosphine High Range |
0-1,000 ppm |
1 ppm |
| Hydrogen Cyanide |
0-50 ppm |
1 ppm |
| Ammonia |
0-300 ppm |
1 ppm |
| Carbon Dioxide |
0-5 Vol % |
0.1 Vol % |
| Chlorine |
0-10 ppm |
0.01 ppm |
| Hydrogen |
0-2,000 ppm |
5 ppm |
| Hydrogen High Range |
0-4 Vol % |
0.01 Vol % |
| Organic Vapor |
0-200 ppm |
1 ppm |
| Organic Vapor-A |
0-200 ppm |
1 ppm |
| Amines |
0-100 ppm |
1 ppm |
| Mercaptan |
0-40 ppm |
1 ppm |
| Phosgene |
0-10 ppm |
0.01 ppm |
| Ozone |
0-10 ppm |
0.01 ppm |
Ordering Information
For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
| Description |
Catalog No. |
| X-am 5000 Confined Space Kit includes pump, tubing, float probe, leather instrument case, charging cradle, power supplies, & case |
4543797 |
| X-am 5000 without Sensorsincludes NiMH Battery & Carger, choose 1 combustible & 3 toxic sensors |
4543748 |
| X-am 5000 without Sensors & Alkaline Battery, choose 1 combustible & 3 toxic sensors |
4543749 |
| X-am 5000 Ex/O2/Dual CO/H2S, NiMH Battery & Charger, Choose 1 toxic sensor |
4543751 |
| X-am 5000, Ex/O2/CO/H2S & Alkaline Battery |
4543782
|
| X-am 5000, Ex/O2/CO/H2S & NiMH Battery & Charger |
4543752
|
| X-am 5000, Ex/O2/CO & NiMH Battery & Charger, choose 1 toxic sensor |
4543753
|
| X-am 5000, Ex/O2/H2S & NiMH Battery & Charger, choose 1 toxic sensor |
4543750
|
| X-am 5000 Ex/O2 & NiMH Battery & Charger, choose 2 toxic sensors |
4543754
|
| X-am 5000 Ex & NiMH Battery & Charger, choose 3 toxic sensors |
4543758
|
| X-am 5000 EX/O2/CO/H2S & NiMH Battery & Charger, 5 year warranty sensors |
4543943
|
Sensor Ordering Information
| Description |
Catalog No. |
| Cat Ex 125 Sensor |
6811050 |
| Oxygen Sensor |
6810881 |
| Carbon Monoxide Sensor |
6810882
|
| Carbon Monoxide Sensor, high range |
6812010
|
| Hydrogen Sulfide Sensor |
6810883
|
| Hydrogen Sulfide Sensor, high range |
6812015
|
| Nitrogen Dioxide Sensor |
6810884
|
| Sulfur Dioxide Sensor |
6810885
|
| Phosphine Sensor |
6810886
|
| Phosphine Sensor, high range |
6812020
|
| Hydrogen Cyanide Sensor |
6810887
|
| Ammonia Sensor |
6810888
|
| Carbon Dioxide Sensor |
6810889
|
| Chlorine Sensor |
6810890
|
| Organic Vapor Sensor |
6811530
|
| Organic Vapor-A Sensor |
6811535
|
| Hydrogen Sulfide Sensor LC, Low Concentration |
6811525
|
| Carbon Monoxide/Hydrogen Sulfide Sensor |
6811410
|
| Carbon Monoxide H2 Compensate Sensor |
6811950
|
| Hydrogen Low Concentration Sensor |
6812370
|
| Hydrogen High Concentration Sensor |
6812025
|
| Nitric Oxide Sensor |
6811545
|
| Amines Sensor |
6812545
|
| Mercaptan Sensor |
6812535
|
| Phosgene Sensor |
6812005
|
| Oxygen Sensor Sensor, 5 year Warranty |
6812211
|
| Carbon Monoxide Sensor, 5 year Warranty |
6812212 |
| Hydrogen Sulfide Sensor, 5 year Warranty |
6812213 |
| Ozone Sensor |
6811540 |
Accessory Ordering Information
| Description |
Catalog No.
|
| Remote Sampling Pump |
8319400
|
| Confined Space Entry Set includes case, tygon tubing, float probe and spare filter |
4543760
|
| Dust/Water Stop filter for Remote Sampling Pump |
4543759 |
| Hand Pump Kit with 10 feet of Tygon Tubing |
4594585 |
| Water Trap, Dust/Mist Filter for Hand Pump |
4523078 |
| NiMHy Battery Kit includes battery, charge cradle & power supply |
8318785 |
| NiMH Battery Pack |
8318704 |
| GasVision Software for data download & management |
8314034 |
| CC-Vision software for calibration & configuration |
6408515 |
| PC Communication Set 1 includes CC-Vision, USB Cable, and Registration Software |
8318761
|
| PC Communication Set 2 includes CC-Vision, USB-IR Cable, Registration Software and Barcode Scanner |
8318762
|
| Telescopic Probe, 4.5' |
4510546
|
| Telescopic Probe, 6.5' |
4510545
|
| 12" Clear Plastic Sample Probe |
4511262 |
| Sample Probe Replacment Filter,3 Hydrophobic & 10 Particulate |
4511290 |
| Float Probe, order hose separately |
6802337 |
| Tygon Sampling Hose, per foot |
4594707 |
| Teflon-Lined Sampling Hose, per foot |
4594679 |
| Bump Test Station w/o gas |
8319131 |
| Printer Set includes printer, connection cable, NiMHy batteries, USB cable, CC-Vision software & tool |
8321011 |
| Deluxe Instrument Case |
4543755 |
| Deluxe Instrument/Pump Case |
8319380 |
| Nylon Transport Case |
4594631
|
Downloads
X-am 5000 literature
|