AFC International - Specialists in gas detection equipment, WMD / Hazmat equipment, Air sampling instrumentation, respiratory protection equipment and isocyanate detectors for product brands like Draeger and MultiRae Systems.  
 
 


Click here to view larger image


Mail E-mail this product to a friend


previous  up  next 

Series B12 Gas Detection Transmitter from Analytical Technology

Series B12 transmitters are loop powered instruments that transmit a 4-20 mA signal linearly proportional to gas concentration. Operated from a 24 VDC power supply, the transmitter will drive loads up to 675 ohms - sufficient for most monitoring applications. Alternatively, the unit can operate at 12 VDC - with reduced output load - for applications requiring battery operation. Transmitters are normally supplied with the sensor close coupled to the enclosure. However, for special applications, the unit can be supplied with separate sensors that can be located up to 25 feet from the transmitter. Sensor duct mounting adapters and sensor flowcells can also be provided for specific applications.

Input Voltage
Maximum Load
12
75
14
175
16
275
18
375
20
475
22
575
24
675
26
775
28
875
30
975

Typical Installation

Gases Available

Gas
Minimum Range
Maximum Range
Acetylene
0-500 ppm
0-2,000 ppm
Acid Gases
0-10 ppm
0-200 ppm
Alcohol
0-500 ppm
0-2,000 ppm
Ammonia
0-100 ppm
0-2,000 ppm
Arsine
0-1,000 ppb
0-5,000 ppb
Bromine
0-1 ppm
0-200 ppm
Carbon Monoxide
0-100 ppm
0-10,000 ppm
Chlorine
0-1 ppm
0-200 ppm
Chlorine Dioxide
0-1 ppm
0-200 ppm
Diborane
0-1,000 ppb
0-5,000 ppb
DMA
0-100 ppm
0-200 ppm
Ethylene Oxide
0-20 ppm
0-200 ppm
Fluorine
0-1 ppm
0-200 ppm
Formaldehyde
0-20 ppm
0-200 ppm
Germane
0-1,000 ppb
0-5,000 ppb
Hydrogen
0-1,000 ppm
0-10%
Hydrogen Chloride
0-10 ppm
0-200 ppm
Hydrogen Cyanide
0-10 ppm
0-200 ppm
Hydrogen Fluoride
0-10 ppm
0-200 ppm
Hydrogen Peroxide
0-10 ppm
0-2,000 ppm
Hydrogen Selenide
0-1,000 ppb
0-5,000 ppb
Hydrogen Sulfide
0-10 ppm
0-1,000 ppm
Iodine
0-1 ppm
0-200 ppm
Nitrogen Dioxide
0-10 ppm
0-200 ppm
Nitric Oxide
0-50 ppm
0-500 ppm
NOx
0-50 ppm
0-500 ppm
Oxygen
0-5%
0-25%
Ozone
0-1 ppm
0-200 ppm
Phosgene
0-1 ppm
0-100 ppm
Phosphine
0-1,000 ppb
0-2,000 ppm
Silane
0-10 ppm
0-50 ppm
Sulfur Dioxide
0-10 ppm
0-200 ppm

Specifications

Range Supplied with standard range for each gas unless otherwise specified
Accuracy Generally ±5% of value, but limited by available calibration gas accuracy
Electronic Repeatability ±1% of full scale
Electronic Linearity ±0.5% of full scale
Zero Drift Sensor dependent, but generally less than 2% of full scale per month,
non-cumulative
Span Drift Application dependent, but generally less than 3% per month
Output Loop powered 4-20 mA, 675 ohms maximum at 24 VDC (except combustible gas)
Power 12-30 VDC
Enclosure NEMA 4X polystyrene. Explosion proof optional, Class 1, Div 1,
Groups B, C & D
Controls Zero and span potentiometers mounted on transmitter circuit board
Display Optional 3-digit LCD (not available with explosion proof enclosure)

B12 Series 2-Wire Transmitter for Wet Gas Streams

Typical Installation

Increasingly stringent air quality requirements have led to expanded use of wet scrubber systems to control air emissions. Chlorine storage facilities and chemical process plants are frequently required to scrub exhaust gas streams to remove halogen and acid gases. Unfortunately, monitoring reactive gas concentration in moisture saturated air streams presents problems for standard diffusion sensors. Condensing water in these air lines can quickly blind diffusion sensors, rendering them inoperable.

ATI's Series B12 Wet Gas System was developed to meet the need for reliable measurements in wet scrubber outlets for other gas streams that might be saturated with water vapor. Systems have been developed for monitoring strong oxidants (chlorine, bromine, chlorine dioxide, or ozone), acid gases (HCl or HF) and hydrogen.

The basic B12 Wet Gas System consists of a loop-powered 2-wire transmitter and a corrosion resistant sensor specifically engineered to operate at 100% RH. Sensors are designed for direct insertion into vent stacks or may be used in a flowcell if sample can be pumped to the sensor.

When remote display and alarm relay functions are required, the B12 Wet Gas Transmitters can be connected to ATI's B14 Alarm Receiver System. This system will provide direct digital display of gas concentration, plus 3 alarm setpoints, remote alarm reset input and retransmit 4-20 mA output. Or, the B12 transmitter may be used separately and tied directly to the users DCS, PLC or other equipment. Either way, the B12 is an excellent solution to a difficult monitoring problem.

Specifications

Gas Type
Oxidant Gases:
Cl2, Br2, ClO2, O3
Acid Gases:
HF, HCl
Hydrogen
Range 0-10, 0-20, 0-50 or
0-100 ppm
0-10, 0-20, 0-50 or
0-100 ppm
0-2% or 0-10%
Accuracy Generally ±5% of value, but limited by available calibration gas accuracy
Electronic Repeatability ±1% of full scale
Electronic Linearity ±0.5% of full scale
Output Loop powered 4-20 mA, 675 ohms, maximum at 24 VDC
Power 12-28 VDC
Enclosures NEMA 4X polystyrene, LCD display optional.
Explosion-proof optional. Class 1, Div 1, Groups B, C & D
Controls Zero and span potentiometers mounted on transmitter circuit board
Operating Temperature 0 to 50°C
Sensor Materials Noryl
Sensor Cable 25 feet standard, 100 feet maximum

Ordering Information

For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.

Downloads

B12 Literature

B12 Wet Gas Literature




 

Related Products


Series B14 - Gas Detection System Controller
Series B14 - Gas Detection System Controller
GasSens Economy Gas Detection System from Analytical Technology
GasSens Economy Gas Detection System from Analytical Technology
SEC 3000 Gas Detection Sensor from Sensor Electronics
SEC 3000 Gas Detection Sensor from Sensor Electronics
RaeGuard 4-20 mA VOC PID Transmitter
RaeGuard 4-20 mA VOC PID Transmitter

Other Recommended Products


Cal 2000 Calibration Gas Generator for all Gas Detectors
Cal 2000 Calibration Gas Generator for all Gas Detectors
 
Series A24 Puffer Bump Test Gas Generator from ATI
Series A24 Puffer Bump Test Gas Generator from ATI
 
Standard 0.5LPM Calibration Gas Regulator
Standard 0.5LPM Calibration Gas Regulator
 
Calibration Gas for Gas Detectors
Calibration Gas for Gas Detectors
 
 
 

Home | About Us | Our Products | Applications | Repair | Resources | Contact Us | Site Map | Login
Products Categories: New Products | Product Specials | Gas Detection | WMD/Hazmat | Isocynate | Air Sampling | Respiratory | Water Quality | Other Instruments | Rental
Product Industries: Industrial Hygiene | Environmental | Confined Space Entry | Fire/Hazmat | Indoor Air Quality (IAQ) | Water Quality | WMD / Law Enforcement

   Popular Product Searches: Ammonia Gas Detector |  Benzene Gas Detector |  Chlorine Gas Detector |  Combustible Gas Detector |  VOC Gas Detector
   Popular Brand Searches: Analytical Technology |  Bacharach Inc |  Crowcon Detection Instruments |  Draeger Safety |  Environics |  GfG Instrumentation |  Honeywell Analytics | 
Rae Systems |  Sensit Technologies |  Sensor Electronics |  Viasensor

AFC International, Inc.
Tel: 800-952-3293 or 219-987-6825 Fax: 219-987-6826
sales@afcintl.com
715 SW Almond St, Ste C | DeMotte, IN 46310
PO Box 894 | DeMotte, IN 46310

Website Maintained by Evolution Point, LLC.

 

Website maintained by Evolution Point - chicago marketing agency, web development chicago, chicago web development, print design, integrated marketing services chicago, interactive agency, search engine optimization, multilanguage website

Web Analytics