E-mail this product to a friend
|
SEC Millennium Infrared Carbon Dioxide Gas Detector
The SEC infrared carbon dioxide detector is a single source dual wavelength instrument. The sensing and reference elements are self-compensating for optical integrity and other signal inhibitors. The industry standard 4-20 mA analog output provides remote alarm, fault and calibration signals.
Features
- Infrared sensing technology
- Virtually maintenance free
- Low cost of ownership, over five years operating life
- Immune to poisoning and etching
- Designed for harsh environments
- Explosion proof
- Compact, lightweight
- Fast response time
- Smart calibration
- Self compensating optical bench and no moving parts
- Heated optical chamber
- Low power consumption
- Operates in anaerobic atmosphere
- Fault indications for all failure states
- Routine calibrations are not required
- 4-20 mA output
- Many ranges available
- RS-485 communication link
- Digital display optional
Applications
- Gas storage
- Injection oil recovery
- Industrial process control
- Food processing & packaging
- Greenhouses
- Bottling plants
- Water industry
- Environmental chambers
- Laboratories
- Breweries & wineries
- HVAC (DCV, energy management)
- Engine test cells
Unit Status Chart
|
Current
|
Output
|
Status
|
|
4-20
|
mA
|
Normal measuring mode |
|
0.0
|
mA
|
Unit fault |
|
0.2
|
mA
|
Reference channel fault |
|
0.4
|
mA
|
Analytical channel fault |
|
0.8
|
mA
|
Unit warm up |
|
1.0
|
mA
|
Optics fault |
|
1.2
|
mA
|
Zero drift fault |
|
1.6
|
mA
|
Calibration fault |
|
2.0
|
mA
|
Unit spanning |
|
2.2
|
mA
|
Unit zeroing |
|
4.0
|
mA
|
Zero gas level |
|
5.6
|
mA
|
10% of full scale |
|
8.0
|
mA
|
25% of full scale |
|
12
|
mA
|
50% of full scale |
|
16
|
mA
|
75% of full scale |
|
20
|
mA
|
100% of full scale |
|
20.1-23
|
mA
|
Over range (>100%) |
Specifications
| Detectable Gases |
Carbon dioxide |
| Range |
0-1% Volume
0-2% Volume
0-5% Volume
Alternate ranges are available |
| Accuracy |
± 3% 0 to 50% full scale
± 5% 51 to 100% full scale |
| Operating Voltage |
18-36 VDC |
| Power Consumption |
4 watts at 24 VDC |
| Analog Output |
4-20 mA (sourced) |
| Response Time |
T50 < 3 seconds
T90 < 5 seconds |
| Humidity |
0-99%, non-condensing |
| EMI Protection |
Complies with: C22.2 No. 152-M1984, ISA S 12.13.01-2000 |
| Operating Temperature |
-40°F to 158°F |
| Enclosure |
316 Stainless Steel |
| Classification |
Class I, Div I, Groups B, C, D |
Ordering Information
For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
Downloads
Millennium CO2 literature.
|