The Cal 2000 provides unmatched versatility and accuracy in corrosive calibration gases. Field replaceable, electrochemical generating cells provide a calibration standard for accurately testing chlorine, chlorine dioxide, hydrogen, hydrogen cyanide and hydrogen sulfide gas sensors.
The Cal 2000 is microprocessor controlled and has an LCD display allowing field adjustable ppm and flow rate. The generating cells are interchangeable and field replaceable. Best of all, the Cal 2000 provides up to 50 times as much calibration gas as a disposable cylinder at approximately the same cost. The electrochemical generating cells do not degrade over time.
The Cal 2000 gas generator has a built in mass flow sensor that automatically compensates for altitude and temperature. The mass flow sensor combined with the instruments internal pump, provide extreme flexibility for calibrating both diffusion and sample draw detection systems.
Features
- A compact hand held size
- Automatic purge on shut down
- Low power consumption
- Alkaline battery powered
- Adjustable ppm and flow rate
- Interchangeable calibration gases
- NIST traceable certificate for Cal 2000 LT
- CSA NRTL/C Exia T-6 approved intrinsically safe with CE mark
Specifications
| Hydrogen Sulfide |
0.5-50 ppm
|
| Hydrogen Sulfide Micro-Cell |
0.05-1 ppm
|
| Chlorine |
0.5-50 ppm
|
| Chlorine Micro-Cell |
0.05-1 ppm
|
| Chlorine Dioxide |
0.5-5.0 ppm
|
| Hydrogen Cyanide |
0.5-50 ppm
|
| Hydrogen |
0.5-50 ppm
|
| Air Flow Rate, with internal pump |
0.2 to 1 LPM
|
| Sample draw Rate, with pump disabled |
0.2 to 5 LPM
|
| Useful Cell Life |
50 or 100 hours
|
| Accuracy |
±10%
|
| Repeatability |
±5%
|
| Warm up Time to 90% |
About 5 minutes
|
| Operating Temperature |
0 to 50°C
|
| Relative Humidity |
0-100%
|
| Battery Power |
4 Alkaline C cells
|
| Battery Life |
10 hours at 0.5 LPM
|
| Size |
8.5" x 4.25" x 3"
|
| Weight |
3 pounds |
| Approvals |
CSA |
Please Note: For Cal 2000: ppm is variable with flow rate, output given at 0.5 LPM
Ordering Information
The Cal 2000 include NIST traceable, 5' hose, nylon carrying case, instructions and batteries. For Cal 2000 LT please specify 0.5 or 1.0 LPM flow rate and ppm concentration. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
| Description |
Catalog No. |
| Cal 2000, Order Cell Separately |
750-0603-00
|
| Chlorine Cell |
510-2000-00
|
| Chlorine Double Life Cell |
510-2000-20
|
| Chlorine Micro-Cell |
510-2000-05
|
| Chlorine Dioxide Cell |
510-2060-00
|
| Chlorine Dioxide Double Life Cell |
510-2060-20
|
| Hydrogen Sulfide Cell |
510-2050-00
|
| Hydrogen Sulfide Micro-Cell |
510-2050-05
|
| Hydrogen Cyanide Cell |
510-2070-00
|
| Hydrogen Cell |
510-2090-00
|
| Hydrogen Double Life Cell |
510-2090-20
|
Downloads
Cal 2000 Gas Generator Literature
Cost Comparison of the Cal 2000 vs the cost of cylinders