The Pac III monitor delivers the most! The loudest audible alarm, the largest display, the easiest to use electronics and the smartest sensors. All of these features are found in this small and rugged gas monitor. Using Draeger Sensor technology, the Pac III is the most versatile gas detection instrument because it can utilize any one of Draeger's 30+ intelligent sensors and quickly switch between them in the field. The Draeger Sensors provide fast and accurate responses to hazardous gas levels while the attention getting gas alarms make sure you know the danger is present. The Pac III provides the most sensing and alarming capabilities of any single gas monitor in the industry today.
Rugged Housing - Many gas monitoring applications are also environmentally challenging. It is not uncommon to work in environments that are hot, cold wet, dirty or affected by corrosive gases. These extreme working environments, such as an offshore oil rig or an underground mine, put equipment to the test. The Pac III was designed to handle these tough conditions in stride. The metal plated ABS housing provides a light weight package that is easy to wear, but can take a beating in the field.
Regardless of accidental drops, unintentional bumps or the occasional submersion in water, the Pac III is still ready to measure gas and sound its alarms. O-rings seal the housing from water or dust. The horn and sensor compartments are sealed against the elements too. The Pac III is ready for the most demanding applications.
RFI Shield - The shiny silver package is not just for looks. The chrome plated housing provides superior resistance to potential Radio Frequency Interference (RFI). This means that you can use walkie talkies in close proximity to the unit without causing false alarms.
In addition to protection against RFI, the metallic coating serves to protect the instrument against heat radiation; a valuable feature in the primary metals industries where high heat exposure is common. The Pac III instrument is fully protected against the environment so it can do its job.
Easy Operation - The Pac III is one tough little instrument but very easy to operate. The three buttons on the front of the unit turn it ON, OFF and access routinely needed data like battery levels. Operations like acknowledging alarms and activating the backlight are clearly marked. Implementing this instrument into your gas monitoring program is a breeze.
Operational Display - The large display constantly communicates information to the user. The gas concentration is continuously shown in large numbers for quick analysis of the situation. Below the concentration is the measurement unit (ppm or % vol) and the gas being measured (CO, Cl2, PH3 etc). Alarm levels (A1 or A2 characters) are also shown in the display. The bottom line of the display is reserved for special information characters. For example, a battery icon tells you when there is a low battery condition. all alarms and warning are announced with an audible and visual signal and a display message or character. The Pac III communicates the information you want and need to know.
Menu-Driven Functions - Functions such as calibration and alarm set points are adjusted through plain language menu commands. These functions are protected by a password to prevent accidental or unauthorized adjustment. In this mode, the three buttons act as up, down and enter buttons to navigate you through the menu. Operation of the Pac III is very intuitive.
The Smartest Technology - The Hygiene version of the Pac III is available for any application that requires documentation and calculation of exposures against TWA, STEL or Ceiling Values. The Pac III is able to record and store in excess of 125 hours @ 1 minute intervals of gas exposure. The averaging period is adjustable to extend the recording length or shorten the averaging period for better resolution of quickly changing conditions.
The Pac III connects to your computer via a standard RS-232 9 pin connector. This information is fed to Draeger's GasVision Software. This Windows based program provides graphic, spread sheet or combined analysis of the collected data. The integrated search engine allows you to recall stored data by the gas, date or person you were monitoring.
Specifications
| Environmental Conditions |
Continuous: -4° to 122°F |
| Intermittent: -40° to 132°F |
| Ingress Protection |
IP66 |
| Typical Battery Life |
9V Alkaline: 600 hours
NiMH:L 200 hours |
| Alarms |
Audible: Piezo-electric buzzer, 95 dBA @ 1 foot
Visual: Two high intensity LED's |
| Warnings |
A1, A2, TWA, STEL and low battery |
| Datalogger |
>125 hours with 1 minute averages |
| Approvals |
UL: Class I&II, Div 1, Grps A-G (T6) |
| CSA: Class I, Div 1, Grps A-D (T6) |
| ATEX: II I G EEx la II C T4 |
| MSHA: Permissible single gas monitor |
*Available on Hygiene version
Sensor Ordering Information
Click on the Catalog No. below for more information on each sensor.
| Gas |
Range |
Resolution
|
XS
Catalog No. |
| Acetaldehyde |
0-200 ppm |
1 ppm
|
6809115 |
| Acetylene |
0-100 ppm |
1 ppm
|
6809115 |
| Acrylonitrile |
0-100 ppm |
0.1 ppm
|
6809522 |
| Ammonia |
0-200 ppm
|
1 ppm
|
|
| Arsine |
0-20.0 ppm |
0.01 ppm
|
6809135 |
| Bromine |
0-20.0 ppm |
0.01 ppm
|
6809165 |
| Butadiene |
0-100 ppm |
1 ppm
|
6809115 |
sec-Butyl
Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
tert-Butyl
Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
| Carbon Dioxide |
0-5.0 Vol % |
0.1 % Vol
|
6809175 |
| Carbon Monoxide |
0-2,000 ppm |
1 ppm
|
6809105 |
|
0-10,000 ppm |
1 ppm
|
6809120 |
| Carbon Monoxide XS-R, 5 year |
0-2,000 ppm
|
1 ppm
|
6810258 |
| Chlorine |
0-20.0 ppm |
0.05 ppm
|
6809165 |
| Chlorine Dioxide |
0-20.0 ppm |
0.05 ppm
|
6809160 |
| Diborane |
0-1.00 ppm |
0.01 ppm
|
6809135 |
| Diethylamine |
0-100 ppm |
1 ppm
|
6809545 |
| Diethyl Ether |
0-200 ppm |
1 ppm
|
6809522 |
| Dimethylamine |
0-100 ppm |
1 ppm
|
6809545 |
| Dimethyl Sulfide |
0-40.0 ppm |
0.1 ppm
|
6809200 |
| Dimethyl Disulfide |
0-40.0 oom
|
0.1 ppm
|
|
| Ethanol |
0-300 ppm |
1 ppm
|
6809115 |
| Ethyl Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
| Ethylene |
0-100 ppm |
1 ppm
|
6809115 |
| Ethylene Oxide |
0-200 ppm |
1 ppm
|
6809115 |
| Formaldehyde |
0-100 ppm |
1 ppm
|
6809115 |
| Flourine |
0-20.0 ppm |
0.01 ppm
|
6809165 |
| Germane |
0-20.0 ppm |
0.01 ppm
|
6809135 |
| Hydrazine |
0-3.00 ppm
|
0.01 ppm
|
|
|
0-3.00 ppm
|
0.01 ppm
|
6810190
1 Yr*
|
| Hydrogen |
0-2,000 ppm |
5 ppm
|
6809185 |
| Hydrogen Chloride |
0-30.0 ppm
|
0.1 ppm
|
|
| Hydrogen Cyanide |
0-50.0 ppm |
0.1 ppm
|
6809150 |
| Hydrogen Fluoride |
0-30.0 ppm
|
0.1 ppm
|
|
| Hydrogen Peroxide |
0-20.0 ppm
|
0.1 ppm
|
|
| Hydrogen Selenide |
0-1.00 ppm |
0.01 ppm
|
6809135 |
| Hydrogen Sulfide |
0-100 ppm |
1 ppm
|
6809110 |
|
0-1,000 ppm |
5 ppm
|
6809180 |
| Hydrogen Sulfide XS-R, 5 year |
0-100 ppm
|
1 ppm
|
6810260 |
| Isobutene |
0-300 ppm |
1 ppm
|
6809522 |
| Isopropyl Alcohol |
0-300 ppm |
1 ppm
|
6809115 |
| Methanol |
0-200 ppm |
1 ppm
|
6809115 |
| Methyl Amine |
0-100 ppm |
1 ppm
|
6809545 |
| Methyl Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
| Nitric Oxide |
0-100 ppm |
1 ppm
|
6809125 |
| Nitrogen Dioxide |
0-50.0 ppm |
0.1 ppm
|
6809155 |
| Oxygen |
0-25 Vol % |
0.1 % Vol
|
6809130 |
|
0-100% Vol
|
0.5% Vol
|
6809550
|
| Oxygen XS-R, 5 year |
0-25 Vol %
|
0.1 % Vol
|
6810262 |
| Phosphine |
0-20.0 ppm
|
0.01 ppm
|
|
|
0-1,000 ppm |
1 ppm
|
6809535 |
| Phosgene |
0-3.00 ppm
|
0.01 ppm
|
|
| Propylene |
0-100 ppm |
1 ppm
|
6809115 |
| Propylene Oxide |
0-200 ppm |
0.1 ppm
|
6809115 |
| Silane |
0-50 ppm |
0.01 ppm
|
6809135 |
| Sulfur Dioxide |
0-100 ppm |
0.1 ppm
|
6809160 |
| Styrene |
0-100 ppm |
1 ppm
|
6809522 |
| Tetrahydrothiophene |
0-40.0 ppm |
0.1 ppm
|
6809200 |
| Triethylamine |
0-100 ppm |
1 ppm
|
6809545 |
| Trimethylamine |
0-100 ppm |
1 ppm
|
6809545 |
| Vinyl Acetate |
0-100 ppm |
1 ppm
|
6809115 |
| Vinyl Chloride |
0-100 ppm |
1 ppm
|
6809115 |
*Note: This sensor can only be used with Pac III, HF/HCl & N2H2 require 450342 Teflon Cap, ordered separately.
Ordering Information
Each Pac III includes a 9V battery, allen tool, belt clip and manual. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
| Description |
Catalog No.
|
| Pac III Hygiene Kit accepts 25+ sensors, datalogger, leather case, carrying case, cable & software |
4530311 |
Accessory Ordering Information
| Description |
Catalog No.
|
| Nylon Transport Case, soft sided |
4594631 |
| Molded Plastic Transport Case |
4056442 |
| Leather Carrying Case with shoulder strap |
4530054 |
| Pac III NiMHy Kit includes charger, charging/download module, and battery pack |
4530367
|
| NiMHy Battery Pack |
4530365 |
| Charging/Download Module, requires power supply |
4530052 |
| Power Supply |
8315635 |
| Dust/Mist Filter, external, pk/5 |
4530046
|
| Hand Aspirator, manual pump |
6801933
|
| Float Probe |
6802337
|
| Calibration/Pump Adapter |
6806291
|
| Tygon Sampling Hose, per foot |
4594707 |
| Teflon-Lined Sampling Hose, per foot |
4594679 |
| Viton Tubing, per foot |
1203150 |
| Pac II Download Kit includes, charging/download module, power supply, RS232 cable & GasVision software |
4530312
|
| GasVision Software |
8314034
|
| RS232 Download Cable |
4530120 |
| Charging/Download Module |
4530052 |
| Sensor Bias Station |
4543505
|
| Ready Reference Card |
4530314
|
| Dust/Mist Filter, pk/5 |
4530046
|
| Sensor Cap, includes cap, seal, O-ring & gasket |
4530048 |
| Teflon Sensor Cap Kit for HF/HCl & N2H2 Sensors |
4530342 |
| Belt Clip includes clip and screws |
4530040 |
| Selective Filter for CO Sensors, pk/1 for acid gases & organic vapors |
6810378 |
| Selective Filter for Sulfur Dioxide Sensors, pk/1 for acid gases |
6809163 |
| Selective Filter for Odorant Sensors, pk/1 for acid gases |
6809198 |
| Dust/Mist Filter, pk/10 |
6809021 |
GasVision Software for data download & data management
|
8314034 |
Downloads
Pac III literature