MiniRae 2000 Portable
VOC Monitor from Rae Systems
The rugged MiniRae 2000 is the smallest pumped handheld volatile organic compound (VOC) monitor on the market. Its Photo ionization Detector (PID) extended range of 0-10,000 ppm makes it an ideal instrument for applications from environmental site surveying to HazMat/Homeland Security.
Features
Proven PID technology - The patented 3D sensor provides a 3 second response up to 10,000 ppm and sets a new standard for resistance to moisture and dirt.
Self cleaning lamp and sensor - Rae's patented self cleaning lamp and sensor minimize the need for maintenance and calibration
The MiniRae 2000 lamp and sensor can be taken apart in seconds for easy maintenance without any tools!
Measures more chemicals than with any other PID - With over 100 correction factors built into the MiniRae 2000 memory and the largest printed list of correction factors in the world (300+), Rae Systems offers the ability to accurately measure more ionizable chemicals than any other PID. When a gas is selected form the MiniRae's 2000's library, the alarm points are automatically loaded into the meter.
User friendly screens make it easy to use for simple applications and flexible enough for sophisticated operations.
Drop in battery - When work schedules require putting in more than the 10 hours supplied by the standard NiMH battery, the drop in alkaline pack supplied with every MiniRae 2000 lets you finish the job.
Rugged rubber boot - the standard rubber boot helps assure that the MiniRae 2000 survives the bumps and knocks of tough field use.
Strong, built in sample pump draws up to 100 feet horizontally and vertically.
Tough flexible inlet probe
Large keys operable with 3 layers of gloves
Stores up to 267 hours of data at one minute intervals for downloading to PC (with the datalogging option).
3 Year 10.6 eV lamp warranty.
Applications
Initial PPE (personal protective equipment) assessment
Leak detection
Perimeter establishment and maintenance
Spill delineation
Decontamination
Remediation
Homeland Security
Confined Space Entry
IAQ
Worker exposure studies
Soil and water headspace analysis
Leaking underground storage tanks
Fugitive emissions (EPA Method 21)
Vapor recovery breakthrough
Landfill monitoring
Specifications
Detector
PID sensor with 10.6 eV lamp standard, 9.8 or 11.7 eV lamp optional
Operating Hours
10 hours continuous
Battery
Rechargeable, external, field replaceable nickel metal hydride battery pack, Alkaline battery holder also supplied
Operating Hours
10 hours continuous
Display
Large, LCD, manual, darkness and alarm activated
Calibration
Two points field calibration of zero and standard reference gas. Calibration memory of 8 calibration gases, alarm limits, span values and calibration time
Keypad
1 operation key, two programming keys
Direct Readout
VOCs as ppm by volume, high and low values, STEL and TWA (in hygiene mode), battery and shut down voltage
Alarms
90 dB buzzer and flashing red LED to indicate exceeded preset limits. High; 3 beeps and flashes per second, Low; 2 beeps and flashes per second, STEL & TWA; 1 beep and flash per second, Alarms automatic reset or latching with manual override, optional plug in pen size vibration alarm, user adjustable alarm limits
Datalogging
Standard 267 hours (at 1 minute intervals) with date/time, header information includes monitor serial number, user ID, site ID, date and time
Communication
Download data and up load instrument setup from PC through RS-232 link to serial port
Low Flow Alarm
Auto shut off pump at low flow condition
Sampling Pump
Internal integrated flow rate 400 cc/min, sample from 100' horizontally or vertically
Temperature
14 to 104°F
Humidity
0 to 95% rH
EMI/RFI
Highly resistant to EMI/RFI, Compliant with EMC Directive 89/336/EEC
IP Rating
IP-55 protected against dust, protected against low pressure jets of water from all directions
Size
8.2" L x 3" W x 2" H
Weight
20 ounces with battery pack
Approvals
UL and cUL: Class 1, Div 1, Group A, B, C, D
Attachment
Durable bright yellow rubber boot with belt clip and wrist strap
Warranty
Lifetime on non-consumable components, 3 years for 10.6 eV PID lamp, 1 year for pump and battery
Sensor Specifications
Sensor
Range
Resolution
Response Time
VOCs
0-999 ppm
0.1 ppm
<3 seconds
100-10,000 ppm
1 ppm
<3 seconds
Ordering Information
Each MiniRae 2000 includes datalogger, software, cable, 10.6 eV PID lamp, probe, filter, rubber boot, alkaline battery adapter, lamp cleaning kit, NiMH battery and charger, operation CD-Rom, manual and soft leather case. The monitor with accessory kit includes all of the above plus hard transport case, metal filters, organic vapor zeroing kit and gas outlet port adapter and tubing. The optional calibration kit adds cal gas and regulator. Each MiniRae 2000 is wireless enabled and certified. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
MiniRae 2000, 10.6 eV Lamp, Charger & Datalogger
011-0201-000
MiniRae 2000, 10.6 eV Lamp, Charger, Datalogger & Calibration Kit