TraceAir organic vapor monitoring badges, originally developed by DuPont, are simple, economical diffusion devices for determining concentrations of organic contaminants in the workplace. Extensive laboratory testing has proven that TraceAir is a reliable sampling method exceeding NIOSH and OSHA accuracy requirement.
Dual Sampling Rates - The TraceAir-1 badge offers the only design with dual sampling rates. Hygienists can sample with the TraceAir-1 badge at 35-50 cc/min with one cover removed or 70-100 cc/min with both covers removed, depending on the compound being sampled. This unique feature enables the user to obtain an increased level of sensitivity when needed and shortens sampling duration for indoor air quality surveys.
Versatile Sampling Application Range - TraceAir offers the hygienist the most versatile application range from 15 minutes short term exposure limits (STEL), eight hour time weighted average (TWA) and up to 16 hour sampling periods, depending upon concentrations.
Free Control/DE Study Strip Provided - Assay Technologies includes an additional charcoal strip at no extra charge in each five-pack of badges. The additional strip may be used for a DE study or as a control blank.
Patented Diffuser Design Provides Advanced Performance - Unlike membrane design badges, the diffuser does not increase response time or risk becoming clogged by aerosols or particulate matter.
The TraceAir-1 badge is ideal for low concentrations and short term sampling. This badge contains a 300mg high capacity coconut based charcoal strip, providing increased surface area for greater capacity than badges using petroleum based charcoal. This extends sampling periods and minimizes sample breakthrough.
The TraceAir-2 badge is ideal for unknown environments. They have increased sampling periods and a back up strip design. The TraceAir-2 badge design offers a second back-up charcoal strip to allow additional material to be sampled at 45% the rate of the first thereby extending the sampling period capacity. The TraceAir-2 badge contains two 300mg charcoal strips and has two times the sampling capacity of other currently available badges.
Compounds Detectable with the TraceAir Badge
Acetic Acid
Diacetone alcohol
Isobutyl acetate
Naphthalene
Acetone
o-Dichlorobenzene
Isobutyl alcohol
n-Octane
Acetonitrile
p-Dichlorobenzene
Isopropyl acetate
n-Pentane
Acetylene dichloride
1,1-Dichloroethane
Isopropyl alcohol
2-Pentanone
Acrylonitrile
1,2-Dichloroethane
Isopropyl ether
Petroleum ether/Naphtha
Allyl alcohol
Dichloroethyl ether
Isopropyl glycidyl ether
Phenyl ether
Allyl chloride
1,2-Dichloroethylene
Kerosene
Phenyl glycidyl ether
Allyl trichloride
Diisobutyl ketone
MIBK
n-Propyl acetate
n & sec-Amyl acetate
Dioxane
Mesityl oxide
n-Propyl alcohol
Benzene
Epichlorohydrin
2-Methoxyethyl acetate
Propylene oxide
Benzyl chloride
Ethanol
2-Methyoxyethanol
Styrene
Bromoform
2-Ethoxyethanol
Methyl acetate
1,1,2,2-Tetrachloro-2,2-difluoroethane
1,3-Butadiene
2-Ethoxyethyl acetate
Methyl acrylate
1,1,1,2-Tetrachloro-1,2-difluoroethane
2-Butoxyethanol
Ethyl acetate
Methylal
Tetrachloroethylene
n, sec & tert-Butyl acetate
Ethyl acrylate
Methyl-(n-amyl)-ketone
Tetrahydrofuran
n, sec & tert-Butyl alcohol
Ethyl amyl ketone
Methyl cellosolve
Toluene
Butyl cellosolve
Ethylbenzene
Methyl cellosolve acetate
Tribromomethane
Butyl glycidyl ether
Ethyl bromide
Methyl chloroform
1,1,2-Trichloroethane
p-t-Butyltoluene
Ethyl butyl ketone
Methyl cyanide
1,1,1-Trichloroethane
Camphor
Ethyl chloride
Methyl cyclohexane
Trichloroethylene
Carbon tetrachloride
Ethylene dibromide
Methyl cyclohexanol
Trichloromethane
Chlorobenzene
Ethylene dichloride
Methylene chloride
1,2,3-Trichloropropane
Chlorobromomethane
Ethyl ether
5-Methyl-3-heptanone
Turpentine
Chloroform
Ethyl formate
Methyl iodide
Vinyl benzene
Chloroprene
Glycidol
Methyl isoamyl acetate
Vinylidene chloride
Cumene
n-Heptane
Methyl isobutyl carbinol
Vinyl toluene
Cyclohexane
Hexachloroethane
Methyl isobutyl ketone
o-Xylene
Cyclohexanol
n-Hexane
Methyl styrene
m-Xylene
Cyclohexene
2-Hexanone
Mineral spirits
p-Xylene
Cylclohexanone
Isoamyl acetate
Naphtha (coal tar)
.
Specifications
Weight
12 grams
Temperature Range
40 to 120°F
Relative Humidity Range
10 to 80%
Face Velocity Range
35 to 400 feet per minute
Dual Sampling Capability
1 cover removed: 35 to 50 cc/min
2 covers removed: 70 to 100 cc/min
System Accuracy
Exceeds NIOSH & OSHA standards
Shelf Life
May be stored at room temperature for 12 months. Monitor should be analyzed immediately after exposure for best results
Analytical Method
Standard NIOSH Manual protocol (3rd edition) performed in AIHA accredited lab
Ordering Information
For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
AFC International, Inc.
PO Box 894, DeMotte, IN 46310
715 SW Almond St, Ste C, DeMotte, IN 46310