Home > Gas Detection > Portable Gas Detectors > Micro IV Single Gas Detector
NEW!! - Micro IV Single Gas Detector from GfG Instrumentation
|
|
The Micro IV is the state of the art successor to the well known Micro III single gas detector. In addition to its simple operation and reliable warning system, the flexible device supersedes all other single gas detectors due to its large memory, an IR interface and a revolutionary docking station.
Event memory saves all important data:
- Time of alarm trigger
- Type of alarm triggered, A1, A2, A3, TWA, STEL value
- Gas concentration present
|
The Micro IV docking station is a trendsetting device management system that greatly reduces cost of ownership and time needed for calibration. The docking station checks acoustic and optical alarm functions, device errors, alarm thresholds and response times for the Micro IV. The bump test comprises:
Up to 6 Micro IVs can be simultaneously calibrated and checked for proper functioning, bump-test.
The docking station dramatically reduces the daily time needed for calibration and function testing, bump test, reducing the annual cost of ownership.
Uncomplicated and quick operation inc connection with self describing "traffic light" signals prevent user errors. Due to its compact size the docking station can be placed almost anywhere without any problems. No additional modules or master stations are necessary.
Specifications
| Temperature Range |
-4 to 122°F |
| Humidity |
5 to 99% rH, non condensing |
| Power |
AA alkaline battery |
| Detection Principle |
Electrochemical |
| Gas Supply |
Diffusion of optional pump |
| Datalogger |
Saves up to 60 events with ga concentration. Event number 61 overwrites oldest event. Saved data can be downloaded to a PC. |
| Alarms |
Vibrator: Standard
Audible: 95 dB at 30 cm
Visual: 2 LED, 360° visible
3 alarms threshold, battery alarm, TWA, STEL |
| Dimensions |
3.5" x 1.85" x 1" |
| Weight |
2-4 ounces |
| Approvals |
ATEX II 2G EEx ib IIC T3/T4 |
Sensor Specifications
|
Sensor
|
Range
|
| Ammonia |
0-500 ppm
|
| Carbon Monoxide |
0-300, 0-1,000 or 0-3,000 ppm
|
| Chlorine Dioxide |
0-2 ppm
|
| Chlorine |
0-10 ppm
|
| Ethylene Oxide |
0-20 ppm
|
| Hydrogen Fluoride |
0-20 ppm
|
| Hydrogen Sulfide |
0-100 or 0-500 ppm
|
| Hydrogen |
0-4% Volume or 0-2,000 ppm
|
| Hydrogen Cyanide |
0-30 or 0-100 ppm
|
| Nitric Oxide |
0-100 ppm
|
| Nitrogen Dioxide |
0-30 ppm
|
| Oxygen |
0-25% Volume
|
| Ozone |
0-1 ppm
|
| Phosgene |
0-1 ppm
|
| Phosphine |
0-10 ppm
|
| Silane |
0-20 ppm
|
| Sulfur Dioxide |
0-10 ppm
|
| Tetrahydrothiophene |
0-100 mg/m3
|
Each Micro IV includes sensor alkaline battery, rubber boot and manual. The Value Kit Configuration includes all of the above plus calibration adapter, calibration gas, regulator and ABS case. (Add K to the part number for Kits) For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
| Description |
Catalog No.
|
| Micro IV Oxygen Gas Detector |
1418-022
|
| Micro IV Carbon Monoxide, 0-300 ppm Gas Detector |
1418-027
|
| Micro IV Carbon Monoxide, 0-1,000 ppm Gas Detector |
1418-107
|
| Micro IV Carbon Monoxide, 0-2,000 ppm Gas Detector |
1418-108
|
| Micro IV Carbon Monoxide plus Hydrogen Sulfide Gas Detector |
1418-105
|
| Micro IV Hydrogen Sulfide, 0-100 ppm Gas Detector |
1418-024
|
| Micro IV Hydrogen Sulfide, 0-500 ppm Gas Detector |
1418-111
|
| Micro IV Chlorine Gas Detector |
1418-153
|
| Micro IV Chlorine Dioxide Gas Detector |
1418-118
|
| Micro IV Ethylene Oxide Gas Detector |
1418-122
|
| Micro IV Hydrogen, 0-2 ppm Gas Detector |
1418-130
|
| Micro IV Hydrogen, 0-1.00% Volume Gas Detector |
1418-131
|
| Micro IV Hydrogen, 0-4.00% Volume Gas Detector |
1418-132
|
| Micro IV Hydrogen Cyanide Gas Detector |
1418-120
|
| Micro IV Nitrogen Dioxide Gas Detector |
1418-116
|
| Micro IV Nitric Oxide Gas Detector |
1418-115
|
| Micro IV Phosphine Gas Detector |
1418-330
|
| Micro IV Sulfur Dioxide Gas Detector |
1418-114
|
| Micro IV Ammonia Gas Detector |
1418-170
|
| Micro IV Hydrogen Fluoride Gas Detector |
1418-126
|
| Micro IV Hydrogen Chloride Gas Detector |
1418-121
|
| Micro IV Ozone Gas Detector |
1418-165
|
| Micro IV Silane Gas Detector |
1418-123
|
| Micro IV Phosgene Gas Detector |
1418-125
|
Accessory Ordering Information
| Description |
Catalog No.
|
| Single Micro IV Docking Station, requires regulator with on/off knob |
1419-204
|
| Docking Station for 3 Micro IV, requires demand flow regulator |
1419-202
|
| Docking Station for 6 Micro IV, require demand flow regulator |
1419-201
|
| Databank Software for automatic saving |
1419-203
|
| Motorized Sample Draw Pump |
1318-911
|
| Manual Hand Aspirator |
7711-004
|
Downloads
|
|
|
Features
Sensors available include oxygen, hydrogen sulfide, carbon monoxide, ammonia, sulfur dioxide, chlorine, phosphine, nitrogen dioxide, hydrogen cyanide, ethylene oxide, chlorine dioxide, hydrogen fluoride, ozone, nitric oxide and hydrogen
Compact and affordable
Real time gas concentrations
Datalogging and event logging standard
Auto zero and calibration
Optional docking station
|