Home > Gas Detection > Portable Gas Detector > Pac 7000 Gas Detector
Pac 7000 Personal Detectors from Draeger Safety
|
|
Small and robust, ergonomic and intuitive, economic and powerful - the Draeger Pac 7000 is tailor made for personal monitoring at the workplace. This innovative single gas detector is equipped with a wide range of functions and is suitable for many different applications in day to day industrial settings The detector is an impressive instrument, offering a high level of reliability and rapid warning against harmful concentrations of CO, H2S, O2, CO2, Cl2, HCN, NH3, NO2, PH3, SO2 and organics. A new low resolution is now available for H2S. The resolution is 0.1 ppm.
|
Small and Robust - With its compact, handy, pocket sized design, Draeger Pac 7000 is tailor made for personal monitoring in daily work activities. The Draeger Pac 7000 was specifically designed as a small and robust instrument to meet work requirements. The impact resistant housing features a protective rubber coating and is resistant to corrosive chemicals. Draeger Pac 7000 meets the requirements of IP 65. What is more, protection against electromagnetic effects was specially optimized, while a stable and tightly locking crocodile clip made of stainless steel allows the instrument to be fastened securely to the wearer's clothing. To allow for individual preferences, the crocodile clip can be turned and the tow alarm lights are positioned diagonally opposite at the corners of the instrument. Easy battery and sensor replacement are key factors to ensure a long instrument life.
Concentration Display - The concentration display uses no written text (to avoid language problems), showing all information in the form of large numerals or symbols. In case of an alarm, or at the push of a button, the display can be backlit for better readability. The currently measured concentration is displayed continuously, as are notice and warning functions In addition, the respective peak concentration, average concentration (TWA value) and short term exposure limit (STEL) relating to the measurement period can be accessed.
New Sensor Technology "en miniature" - Draeger Pac 7000 boasts the latest in sensor technology. The small size of the sensor supports the application oriented design of the instrument. Any gas hazards that may occur are displayed immediately thanks to the very short diffusion paths inside the instrument and the extremely quick electrochemical reaction times achieved by the new sensors. The sensor is positioned inside the housing such as to allow gas to reach it from above and from in front. This positioning minimizes the danger of the gas inlet opening being accidentally covered.
Alarm/Warning Functions - In conjunction with a vibration alarm, a visual and audible alarm is triggered if the two adjustable alarm thresholds are exceeded (or if oxygen levels fall below the set value). For optimum perception a two tone alarm is used. Further more, Draeger Pac 7000 features an adjustable TWA alarm and STEL alarm. A warning is likewise given at the end of the battery capacity or in the event of a device error.
Bump Test Mode - The safety of personnel must always have the first priority. Their safety depends on measurement and warning equipment functioning perfectly, which is why national regulations demand regular testing of equipment function using a know gas concentration. Draeger Pac 7000 is equipped with a bump test mode. When a bump test (function test or challenge test) needs to be performed, a notice icon appears on the screen. The bump test interval can be set by the user. The result of the bump test is saved in the instrument's memory. Draeger Bump Test Station is available for easy performance of the bump test.
Calibration and Configuration - Draeger Pac 7000 features a menu from which the bump test mode, fresh air calibration and span calibration can be selected. Access to fresh and span calibration can be password protected. The instrument is equipped with an IR interface and can be linked to a PC via the connecting cradle or E-Cal system. Draeger Pac Vision or Draeger CC Vision software installed on the PC enables configuration of all functions, as well as calibration and download of the stored data.
Adjusting Operating Time - In addition, the instrument allows an individual operating time to be set (in days), e.g. a calibration interval, inspection interval or individual operating time end.
Data Logger - Draeger Pac 7000 features a data logger in which all concentrations and events are stored together with their respective dates and times. The intervals at which peak concentrations are saved are variable and can be adjusted by the user. If a one minute interval is set, the data logger has a capacity of about five days. The stored data can be downloaded via a PC and the installed Draeger Pac Vision or Draeger CC Vision software and edited using, for example Microsoft Excel software of Draeger GasVision software.
Sensor Specifications
|
Sensor
|
Range
|
Alarm A1
|
Alarm A2
|
| Carbon Monoxide |
0-1,999 ppm
|
35 ppm
|
50 ppm
|
| Hydrogen Sulfide |
0-100 ppm
|
10 ppm
|
20 ppm
|
| Hydrogen Sulfide, 0.1 ppm resolution |
0-100 ppm
|
10 ppm
|
20 ppm
|
| Oxygen |
0-25 Vol %
|
19.5 Vol %
|
23.5 Vol %
|
| Carbon Dioxide |
0-5 Vol %
|
0.5 Vol %
|
1.0 Vol %
|
| Chlorine |
0-20 ppm
|
0.5 ppm
|
1.0 ppm
|
| Hydrogen Cyanide |
0-50 ppm
|
2.5 ppm
|
4.5 ppm
|
| Ammonia |
0-300 ppm
|
25 ppm
|
50 ppm
|
| Nitrogen Dioxide |
0-50 ppm
|
2.5 ppm
|
5.0 ppm
|
| Phosgene |
0-20 ppm
|
0.1 ppm
|
0.2 ppm
|
| Sulfur Dioxide |
0-100 ppm
|
2 ppm
|
4 ppm
|
| Organic Vapor |
0-200 ppm
|
5 ppm
|
10 ppm
|
| Organic Vapor-A |
0-200 ppm
|
5 ppm
|
10 ppm
|
Specifications
| Display |
Language free LCD display, continuous indication of concentration, indication of concentration during alarm, peak concentrations, TWA and STEL concentrations, operating time, notice and warning functions |
| Data Logger |
Storage of concentration and events with date and time |
| Temperature Range |
-20 to 120°F |
| Humidity |
10 to 90% rH |
| Protection Class |
IP 65 |
| Battery Life |
CO & H2S: > 5,500 hours |
| O2: >2,700 hours |
| Approvals |
UL: Class I, II Div 1, Group A, B, C, D, E, F, G, T4 |
| cUL: Class I, II Div 1, Group A, B, C, D, E, F, G, T4 |
| ATEX: II 1 G EEx ia IIC, T4, 1M 1 EEx ia I, T4 |
| Acoustic Alarm |
Two tone alarm, typical > 90 dB (A) at a distance of 30 cm |
| Size |
2.5" x 3.3" x 0.8" |
| Weight |
3.8 ounces |
For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.
| Description |
Catalog No.
|
| Pac 7000 for Carbon Monoxide |
8318970
|
| Pac 7000 for Oxygen |
8318972
|
| Pac 7000 for Hydrogen Sulfide |
8318971
|
| Pac 7000 for Carbon Dioxide |
8318975
|
| Pac 7000 for Chlorine |
8318978
|
| Pac 7000 for Hydrogen Cyanide |
8318973
|
| Pac 7000 for Ammonia |
8318979
|
| Pac 7000 for Nitrogen Dioxide |
8318977
|
| Pac 7000 for Phosgene |
8318974
|
| Pac 7000 for Sulfur Dioxide |
8318976
|
| Pac 7000 for Organic Vapors |
8321006
|
| Pac 7000 for Organic Vapors - A |
8321007
|
| Pac 7000 for Carboxyhemglobin Kit includes monitor, mouthpieces, cradle |
4543876
|
| Pac 7000 for Hydrogen Sulfide, Low Resolution Sensor |
8321004
|
Accessory Ordering Information
| Description |
Catalog No.
|
| Connecting Cradle, complete with USB cable and Pac Vision software |
8318587
|
| Lithium Battery |
4543808
|
| Dust and Water Filter, pk/4 |
4543836
|
| Leather Carrying Case |
4543822
|
| Bump Test Station, gas cylinder included |
8317410
|
| Smart Bump/Cal Station for auto bumptest |
8319559
|
| Printer Set for Smart Bump/Cal Station includes printer, charger, rechargeable batteries, USB cable, positioning aid, CC-Vision |
8321010
|
| E-Cal Instrument Module |
8318589
|
| Bump Test/Calibration Adapter |
8318588
|
| Mouthpieces for COHb Measurement, pk/25 |
6805703
|
| MSHA Approval Label, installed |
4543883
|
| GasVision Software for data downloading and data management, requires 8318587 |
8314034
|
| H2S Selective Filter for SO2 Sensor |
6811344
|
Downloads
|
|
|
Features
Gas inflow from top and front
Unlimited instrument life
Easy sensor replacement
No text display
Continuous concentration display
Visual, audible & vibration alarm
Two adjustable alarm thresholds
Adjustable TWA & STEL alarm
Display of peak concentration
Battery pre and main alarm
Adjustable operating time with pre and main alarm
Adjustable bump test interval & bump test mode
Password protected menu for fresh air and sensitivity calibration
IR interface
Individual instrument configuration
Replaceable battery
Data logger
|