Home > Gas Detection > Portable Gas Detector > Pac III Gas Detector

Pac III Single Gas Detector
from Draeger Safety

Pac III Single Gas Detector
  • Intelligent sensor technology
  • Detect more than 50 gases with just 1 monitor
  • Dust tight, water resistant, metal plated case
  • Two user settable alarm points

The Pac III monitor delivers the most! The loudest audible alarm, the largest display, the easiest to use electronics and the smartest sensors. All of these features are found in this small and rugged gas monitor. Using Draeger Sensor technology, the Pac III is the most versatile gas detection instrument because it can utilize any one of Draeger's 20+ intelligent sensors and quickly switch between them in the field. The Draeger Sensors provide fast and accurate responses to hazardous gas levels while the attention getting gas alarms make sure you know the danger is present. The Pac III provides the most sensing and alarming capabilities of any single gas monitor in the industry today.

The Pac III has menu-driven functions. It is operated with a simple, three-button key-pad and a completely text driven menu with password protection, for improved security. In its operating mode, Pac III continuously measures gas concentration and compares the current gas concentration against the user configurable alarm values.

The Pac III uses an alkaline battery that yields over 600 hours of operation. A Hygiene (datalogger) version of the Pac III is available for any application which requires documentation of TWA, STEL or ceiling value exposure. The Hygiene version may also be configured to enable European or ACGIH advanced industrial hygiene functions.

Pac III With Pump

Specifications

Environmental Conditions Continuous: -4° to 122°F
Intermittent: -40° to 132°F
Ingress Protection IP66
Typical Battery Life 9V Alkaline: 600 hours
Alarms Pre-alarm, main alarm, TWA alarm*, STEL alarm*, STEL frequency alarm*, very low battery
Warnings Low battery, expired sensor, expired calibration, error in calibration
Horn Loudness >95 dB @ 1 ft
Approvals UL: Class I&II, Div 1, Grps A-G (T6)
CSA: Class I, Div 1, Grps A-D (T6)
CENELEC: EEx ia IIC T4/T6 (BVS) EEx ia I
MSHA: Permissible single gas monitor
*Available on Hygiene version

Sensor Ordering Information

Click on the Catalog No. below for more information on each sensor.
Gas
Range
Resolution
XS
Catalog No.
XS-R
Catalog No.
Acetaldehyde
0-200 ppm
1 ppm
6809115
-
Acetylene
0-100 ppm
1 ppm
6809115
-
Acrylonitrile
0-100 ppm
0.1 ppm
6809522
-
Ammonia
0-200 ppm
1 ppm
-
Arsine
0-20.0 ppm
0.01 ppm
6809135
-
Bromine
0-20.0 ppm
0.01 ppm
6809165
-
Butadiene
0-100 ppm
1 ppm
6809115
-
sec-Butyl Mercaptan
0-40.0 ppm
0.1 ppm
-
tert-Butyl Mercaptan
0-40.0 ppm
0.1 ppm
-
Carbon Dioxide
0-5.0 Vol %
0.1 % Vol
6809175
-
Carbon Monoxide
0-2,000 ppm
1 ppm
6809105
4595401
0-10,000 ppm
1 ppm
6809120
-
Chlorine
0-20.0 ppm
0.05 ppm
6809165
-
Chlorine Dioxide
0-20.0 ppm
0.05 ppm
6809165
-
Diborane
0-1.00 ppm
0.01 ppm
6809135
-
Diethylamine
0-100 ppm
1 ppm
6809545
-
Diethyl Ether
0-200 ppm
1 ppm
6809522
-
Dimethylamine
0-100 ppm
1 ppm
6809545
-
Dimethyl Sulfide
0-40.0 ppm
0.1 ppm
6809200
-
Dimethyl Disulfide
0-40.0 oom
0.1 ppm
-
Ethanol
0-300 ppm
1 ppm
6809115
-
Ethyl Mercaptan
0-40.0 ppm
0.1 ppm
-
Ethylene
0-100 ppm
1 ppm
6809115
-
Ethylene Oxide
0-200 ppm
1 ppm
6809115
-
Formaldehyde
0-100 ppm
1 ppm
6809115
-
Flourine
0-20.0 ppm
0.01 ppm
6809165
-
Germane
0-20.0 ppm
0.01 ppm
6809135
-
Hydrazine
0-3.00 ppm
0.01 ppm
-
0-3.00 ppm
0.01 ppm
6810190
1 Yr*
-
Hydrogen
0-2,000 ppm
5 ppm
6809185
-
Hydrogen Chloride
0-30.0 ppm
0.1 ppm
-
Hydrogen Cyanide
0-50.0 ppm
0.1 ppm
6809150
-
Hydrogen Fluoride
0-30.0 ppm
0.1 ppm
-
Hydrogen Peroxide
0-20.0 ppm
0.1 ppm
-
Hydrogen Selenide
0-1.00 ppm
0.01 ppm
6809135
-
Hydrogen Sulfide
0-100 ppm
1 ppm
6809110
4595402
0-1,000 ppm
5 ppm
6809180
-
Isobutene
0-300 ppm
1 ppm
6809522
-
Isopropyl Alcohol
0-300 ppm
1 ppm
6809115
-
Methanol
0-200 ppm
1 ppm
6809115
-
Methyl Amine
0-100 ppm
1 ppm
6809545
-
Methyl Mercaptan
0-40.0 ppm
0.1 ppm
-
Nitric Oxide
0-100 ppm
1 ppm
6809125
-
Nitrogen Dioxide
0-50.0 ppm
0.1 ppm
6809155
-
Oxygen
0-25 Vol %
0.1 % Vol
6809130
4595400
0-100% Vol
0.5% Vol
6809550
-
Phosphine
0-20.0 ppm
0.01 ppm
-
0-1,000 ppm
1 ppm
6809535
-
Phosgene
0-3.00 ppm
0.01 ppm
-
Propylene
0-100 ppm
1 ppm
6809115
-
Propylene Oxide
0-200 ppm
0.1 ppm
6809115
-
Silane
0-50 ppm
0.01 ppm
6809135
-
Sulfur Dioxide
0-100 ppm
0.1 ppm
6809160
-
Styrene
0-100 ppm
1 ppm
6809522
-
Tetrahydrothiophene
0-40.0 ppm
0.1 ppm
6809200
-
Triethylamine
0-100 ppm
1 ppm
6809545
-
Trimethylamine
0-100 ppm
1 ppm
6809545
-
Vinyl Acetate
0-100 ppm
1 ppm
6809115
-
Vinyl Chloride
0-100 ppm
1 ppm
6809115
-

*Note: This sensor can only be used with Pac III, HF/HCl & N2H2 require 450342 Teflon Cap, ordered separately.

Ordering Information

Click here for information on the E-Cal instrument calibrating and management system from Draeger Safety.

Each Pac III includes a 9V battery, allen tool, belt clip and manual. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com

Description
Catalog No.
Pac III Standard accepts 25+ interchangeable sensors
4530010
Pac III Hygiene accepts 25+ sensors and has datalogging & TWA, STEL operating capabilities
4530011
Pac III Hygiene Kit accepts 25+ sensors, datalogger, leather case, carrying case, cable & software
4530311

Accessory Ordering Information

Description
Catalog No.
Nylon Transport Case, soft sided
4594631
Leather Carrying Case with shoulder strap
4530054
Pac III NiMHy Kit includes charger, charging/download module, and battery pack
4530367
NiMHy Battery Pack
4530365
Charging/Download Module, requires power supply
4530052
Power Supply
8315635
Dust/Mist Filter, external, pk/5
4530046
SmartPump, require calibration/pump adapter & hose
8313832
Water & Dust Filter for SmartPump
6801933
Calibration/Pump Adapter
6802337
CC-Vision Software for calibration & configuration
6408515
E-Cal Module
8316554
E-Cal Modle Adapter, USB
8319409
Pac II Download Kit includes, charging/download module, power supply, RS232 cable & GasVision software
4530312
GasVision Software
8314034
Sensor Bias Station
4543505
Ready Reference Card
4530314
Pac III Operator Training CD
4530369
Pac III Interactive Computer Based Training CD
8317853

Download a copy of the Pac III literature

New Products | Air Sampling | Gas Detection | Other Meters | Respiratory | Water Quality | WMD HazMat
Applications | Product Specials | Rentals | Links | Index | Contact Us | Home


AFC International, Inc.
PO Box 894, DeMotte, IN 46310
715 SW Almond St, Ste C, DeMotte, IN 46310
800-952-3293 219-987-6825 Fax 219-987-6826
eMail: sales@afcintl.com

Last Revised: 2/19/08