Home > Gas Detection > Portable Gas Detector > Pac III Gas Detector
Pac III Single Gas Detector from Draeger Safety
|
|
The Pac III monitor delivers the most! The loudest audible alarm, the largest display, the easiest to use electronics and the smartest sensors. All of these features are found in this small and rugged gas monitor. Using Draeger Sensor technology, the Pac III is the most versatile gas detection instrument because it can utilize any one of Draeger's 20+ intelligent sensors and quickly switch between them in the field. The Draeger Sensors provide fast and accurate responses to hazardous gas levels while the attention getting gas alarms make sure you know the danger is present. The Pac III provides the most sensing and alarming capabilities of any single gas monitor in the industry today.
|
|
The Pac III has menu-driven functions. It is operated with a simple, three-button key-pad and a completely text driven menu with password protection, for improved security. In its operating mode, Pac III continuously measures gas concentration and compares the current gas concentration against the user configurable alarm values.
The Pac III uses an alkaline battery that yields over 600 hours of operation. A Hygiene (datalogger) version of the Pac III is available for any application which requires documentation of TWA, STEL or ceiling value exposure. The Hygiene version may also be configured to enable European or ACGIH advanced industrial hygiene functions.
|
|
Specifications
| Environmental Conditions |
Continuous: -4° to 122°F |
| Intermittent: -40° to 132°F |
| Ingress Protection |
IP66 |
| Typical Battery Life |
9V Alkaline: 600 hours |
| Alarms |
Pre-alarm, main alarm, TWA alarm*, STEL alarm*, STEL frequency alarm*, very low battery |
| Warnings |
Low battery, expired sensor, expired calibration, error in calibration |
| Horn Loudness |
>95 dB @ 1 ft |
| Approvals |
UL: Class I&II, Div 1, Grps A-G (T6) |
| CSA: Class I, Div 1, Grps A-D (T6) |
| CENELEC: EEx ia IIC T4/T6 (BVS) EEx ia I |
| MSHA: Permissible single gas monitor |
*Available on Hygiene version
Sensor Ordering Information
Click on the Catalog No. below for more information on each sensor.
| Gas |
Range
|
Resolution
|
XS
Catalog No.
|
XS-R
Catalog No.
|
| Acetaldehyde |
0-200 ppm
|
1 ppm
|
6809115
|
-
|
| Acetylene |
0-100 ppm
|
1 ppm
|
6809115
|
-
|
| Acrylonitrile |
0-100 ppm
|
0.1 ppm
|
6809522
|
-
|
| Ammonia |
0-200 ppm
|
1 ppm
|
|
-
|
| Arsine |
0-20.0 ppm
|
0.01 ppm
|
6809135
|
-
|
| Bromine |
0-20.0 ppm
|
0.01 ppm
|
6809165
|
-
|
| Butadiene |
0-100 ppm
|
1 ppm
|
6809115
|
-
|
| sec-Butyl Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
-
|
| tert-Butyl Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
-
|
| Carbon Dioxide |
0-5.0 Vol %
|
0.1 % Vol
|
6809175
|
-
|
| Carbon Monoxide |
0-2,000 ppm
|
1 ppm
|
6809105
|
4595401
|
|
0-10,000 ppm
|
1 ppm
|
6809120
|
-
|
| Chlorine |
0-20.0 ppm
|
0.05 ppm
|
6809165
|
-
|
| Chlorine Dioxide |
0-20.0 ppm
|
0.05 ppm
|
6809160
|
-
|
| Diborane |
0-1.00 ppm
|
0.01 ppm
|
6809135
|
-
|
| Diethylamine |
0-100 ppm
|
1 ppm
|
6809545
|
-
|
| Diethyl Ether |
0-200 ppm
|
1 ppm
|
6809522
|
-
|
| Dimethylamine |
0-100 ppm
|
1 ppm
|
6809545
|
-
|
| Dimethyl Sulfide |
0-40.0 ppm
|
0.1 ppm
|
6809200
|
-
|
| Dimethyl Disulfide |
0-40.0 oom
|
0.1 ppm
|
|
-
|
| Ethanol |
0-300 ppm
|
1 ppm
|
6809115
|
-
|
| Ethyl Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
-
|
| Ethylene |
0-100 ppm
|
1 ppm
|
6809115
|
-
|
| Ethylene Oxide |
0-200 ppm
|
1 ppm
|
6809115
|
-
|
| Formaldehyde |
0-100 ppm
|
1 ppm
|
6809115
|
-
|
| Flourine |
0-20.0 ppm
|
0.01 ppm
|
6809165
|
-
|
| Germane |
0-20.0 ppm
|
0.01 ppm
|
6809135
|
-
|
| Hydrazine |
0-3.00 ppm
|
0.01 ppm
|
|
-
|
|
0-3.00 ppm
|
0.01 ppm
|
6810190
1 Yr*
|
-
|
| Hydrogen |
0-2,000 ppm
|
5 ppm
|
6809185
|
-
|
| Hydrogen Chloride |
0-30.0 ppm
|
0.1 ppm
|
|
-
|
| Hydrogen Cyanide |
0-50.0 ppm
|
0.1 ppm
|
6809150
|
-
|
| Hydrogen Fluoride |
0-30.0 ppm
|
0.1 ppm
|
|
-
|
| Hydrogen Peroxide |
0-20.0 ppm
|
0.1 ppm
|
|
-
|
| Hydrogen Selenide |
0-1.00 ppm
|
0.01 ppm
|
6809135
|
-
|
| Hydrogen Sulfide |
0-100 ppm
|
1 ppm
|
6809110
|
4595402
|
|
0-1,000 ppm
|
5 ppm
|
6809180
|
-
|
| Isobutene |
0-300 ppm
|
1 ppm
|
6809522
|
-
|
| Isopropyl Alcohol |
0-300 ppm
|
1 ppm
|
6809115
|
-
|
| Methanol |
0-200 ppm
|
1 ppm
|
6809115
|
-
|
| Methyl Amine |
0-100 ppm
|
1 ppm
|
6809545
|
-
|
| Methyl Mercaptan |
0-40.0 ppm
|
0.1 ppm
|
|
-
|
| Nitric Oxide |
0-100 ppm
|
1 ppm
|
6809125
|
-
|
| Nitrogen Dioxide |
0-50.0 ppm
|
0.1 ppm
|
6809155
|
-
|
| Oxygen |
0-25 Vol %
|
0.1 % Vol
|
6809130
|
4595400
|
|
0-100% Vol
|
0.5% Vol
|
6809550
|
-
|
| Phosphine |
0-20.0 ppm
|
0.01 ppm
|
|
-
|
|
0-1,000 ppm
|
1 ppm
|
6809535
|
-
|
| Phosgene |
0-3.00 ppm
|
0.01 ppm
|
|
-
|
| Propylene |
0-100 ppm
|
1 ppm
|
6809115
|
-
|
| Propylene Oxide |
0-200 ppm
|
0.1 ppm
|
6809115
|
-
|
| Silane |
0-50 ppm
|
0.01 ppm
|
6809135
|
-
|
| Sulfur Dioxide |
0-100 ppm
|
0.1 ppm
|
6809160
|
-
|
| Styrene |
0-100 ppm
|
1 ppm
|
6809522
|
-
|
| Tetrahydrothiophene |
0-40.0 ppm
|
0.1 ppm
|
6809200
|
-
|
| Triethylamine |
0-100 ppm
|
1 ppm
|
6809545
|
-
|
| Trimethylamine |
0-100 ppm
|
1 ppm
|
6809545
|
-
|
| Vinyl Acetate |
0-100 ppm
|
1 ppm
|
6809115
|
-
|
| Vinyl Chloride |
0-100 ppm
|
1 ppm
|
6809115
|
-
|
*Note: This sensor can only be used with Pac III, HF/HCl & N2H2 require 450342 Teflon Cap, ordered separately.
| Description |
Catalog No.
|
| Pac III Standard accepts 25+ interchangeable sensors |
4530010
|
| Pac III Hygiene accepts 25+ sensors and has datalogging & TWA, STEL operating capabilities |
4530011
|
| Pac III Hygiene Kit accepts 25+ sensors, datalogger, leather case, carrying case, cable & software |
4530311
|
Accessory Ordering Information
| Description |
Catalog No.
|
| Nylon Transport Case, soft sided |
4594631
|
| Leather Carrying Case with shoulder strap |
4530054
|
| Pac III NiMHy Kit includes charger, charging/download module, and battery pack |
4530367
|
| NiMHy Battery Pack |
4530365
|
| Charging/Download Module, requires power supply |
4530052
|
| Power Supply |
8315635
|
| Dust/Mist Filter, external, pk/5 |
4530046
|
| Hand Aspirator, manual pump |
6801933
|
| Float Probe |
6802337
|
| Calibration/Pump Adapter |
6806291
|
| CC-Vision Software for calibration & configuration |
6408515
|
| E-Cal Module |
8316554
|
| E-Cal Master Station |
8319456
|
| Pac II Download Kit includes, charging/download module, power supply, RS232 cable & GasVision software |
4530312
|
| GasVision Software |
8314034
|
| Sensor Bias Station |
4543505
|
| Ready Reference Card |
4530314
|
| Pac III Operator Training CD |
4530369
|
Downloads
Pac III literature
|
|
|
Features
Intelligent sensor technology
Detect more than 50 gases with just 1 monitor
Dust tight, water resistant, metal plated case
Two user settable alarm points
|