Multi-Zone Fixed Point Refrigerant Leak Monitors
|
|
AGM300/ADM800
For continuous multi point monitoring of ammonia refrigerant gases
|
 |
HGM300/RDM800
For continuous multi point monitoring of CFC, HFC HCFC and halon refrigerant gases
|
These monitors enable up to 16 individual zones to be monitored continuously. Using split architecture design, advanced infrared technology and the latest in network communcation protocols, these monitors provide reliable point by point refrigerant loss monitoring at concentration levels as low as 1 ppm.
Innovations in Infrared Technology
- Select refrigerants to be measured - point by point!
- Eliminate false alarms with use of a non-dispersive IR source with sample draw system
- Measure all gases up to 10,000 ppm with a sensitivity of 1 ppm
- Sample points up to 500 feet from unit
Split Architecture Design
- Remotely acknowledge alarms provide maintenance and evaluate operating conditions
- Quick field expansion from 4 to 16 sampling zones with only a screwdriver
- Bolt in Bolt out internal components so the unit never leaves the wall
Enhanced Communication Protocols
- Full two way communication through RS-485 to the remote display module and building management systems such as Modbus RTU
- RS232C port for local/modem communication
Cost Effective
- Split architecture design keeps your investment to a minimum
- Two year warranty protects your investment
Specifications - HGM300 & AGM300
| HGM300 |
CFC: R-11, R-12, R-113, R-114, R-502
HFC: R-404a, R-407a, R-407c, R-134a, R-410a, R-507, R-508b
HCFC: R-22, R-123, R-124, R-500, R-503, R-401a, R-402a, R-40b, R-409a, R-23
Halon: 1301 |
| AGM300 |
R-717 ammonia |
| Inputs |
4 point std, expandable to 16 points in 4 point increments |
| Output Signal |
3 SPDT, 5 Amp, 240VAC rated alarm relays and 1 SPDT, 5 Amp 240 VAC faced system fault, relay plus a digital display with an optional dual 4-20 mA DC analog output |
| Detector Type |
Non-dispersive infrared |
| Measuring Range |
Refrigerant: 0-10,000 ppm
Ammonia: 25 to 10,000 ppm |
| Sensitivity |
All gases 1 ppm |
| Accuracy |
All gases +/- 10 ppm from 0 to 100 ppm
+/- 10% of reading from 100 to 10,000 ppm |
| Front Panel Display |
Green LED indicates when unit is operating properly
Red LED indicates when any monitored point is above its alarm setting
Yellow LED indicates a clogged sample line or other system fault |
| Response Time |
5 to 120 seconds depending on tube length and gas concentration |
| Maximum Monitoring Distance |
Up to 500 feet from measuring point to monitor |
| Power |
120 VAC/ 60 Hz standard
240 VAC/ 50 Hz |
| Size |
17"L x 12" W x 5.5" D |
| Weight |
15 pounds |
Specifications - RDM300 & ADM300 (Remote Display Models)
| Inputs |
Accepts from 1 to 4 inputs via RS-485 from up to 4 HGM3000 refrigerant models |
| Display |
Backlit LCD display the measured point in ppm |
| Trend Mode/Datalogging |
User may select a graphical display of the ppm trend for any measured point (100 data entries per point) |
| Output Signal |
2 SPDT, 5 Amp, 240 VAC assignable alarm relays |
| Alarm Indications |
Channel display flashes, red light flashes, alarm signal sent via RS-485 |
| Input Fault Indication |
Yellow light flashes and the LCD indicates location of input fault |
| Maximum Monitoring Distance |
Maximum of 4,875 wiring feet from furthest HGM300 to RDM800 display |
| Power |
120 VAC/ 60 Hz standard
240 VAC/ 50 Hz |
| Size |
11"L x 10" W x 3" D |
| Weight |
5 pounds |
Ordering Information