| Analog Inputs |
16 single ended, 4-20 mA DC
(internal 24 VDC power supply for external transmitters) |
| A/D Conversion |
14 bit internal resolution |
| Relay Outputs |
6 SPDT relays standard, 30 additional open collectors for expansion relays |
| Relay Contacts |
10 A at 120 VAC, 5 A at 220 VAC resistive |
| Serial Output |
Selectable RS-232 or RS-485, 2400 or 9600 baud |
| Display |
2 line x 16 character backlit alphanumeric LCD |
| Power |
90-264 VAC, 47-63 Hz., or 12 VDC |
| Alarm Setpoints |
Two independent setpoints per channel |
| Failure Alarm |
Activated on loss of input or -10% zero shift |
| Alarm LEDs |
16 LED indicators mounted on front panel |
| Audible Alarm |
Standard on NEMA 4X units |