Home > Gas Detection > Portable Gas Detector > PortaSens II Leak Detector
PortaSens II Leak Detector from Analytical Technology
|
|
The PortaSens II portable gas leak detector is a versatile tool for performing regular leak checks in gas storage areas, around process equipment and piping, or in confined spaces prior to entry. Designed for easy one hand operation, the detector contains an internal sample pump and a flexible sampling wand to allow pinpoint location of the source of leakage. A large character display insures that measured values are easily visible and a backlight for the display insures readability in low or no light conditions.
A unique feature of the PortaSens II is it's ability to measure a variety of different gases by simply inserting the appropriate sensor for that gas. This means that one detector can be used to measure over 30 different
|
gases or vapors, reducing the need to purchase individual detectors for each type of gas. And sensors can be changed quickly and easily without the need for calibration when a sensor change is made.
Sensors used in the PortaSens are ATI's newest miniaturized smart sensor modules. Each sensor module is actually a sensor, amplifier and memory module in one compact package. Because of this design, sensor modules can be calibrated independently and simply plugged into any detector for immediate use. When installed in a detector, calibration data is loaded into the microprocessor so that no adjustments are needed. The result is that a detector can go from phosgene measurement to ammonia measurement in less than one minute.
Specifications
| Range |
Dependent on gas, see chart below |
| Display |
Backlit graphics, LCD |
| Accuracy |
+/-5% of value, sensor dependent |
| Sensitivity |
1% of sensor module range |
| Outputs |
RS-232 output of stored gas values, 0- VDC analog, requires optional output cable |
| Memory |
12,000 data points |
| Storage Interval |
Programmable, 1 to 60 minute |
| Typical Capacity |
8 days at 1 minute intervals |
| Alarms |
Three concentration alarms, low flow alarm & low battery alarm, alarms displayed on LCD |
| Power |
D cell battery, alkaline recommended, 75 hours operation. Rechargeable NiCad battery for backup power, 6 hours operation |
| Pump |
Miniature rotary vane type 400 cc/min nominal |
| Operating Temperature |
-25 to 55°C |
| Humidity |
0-95%, non condensing |
| Size |
3.5" W x 9" H x 5.5" D |
| Weight |
7 pounds |
The PortaSens II is supplied in a padded carrying case for easy storage and transport. Space is provided for an extra battery plus up to two sensor keepers, which means up to 8 extra sensors ready for immediate use. Each PortaSens II includes the detector, 10" Teflon lined sampling wand, battery charger, spare filters, flowmeter, RS-232 output cable, spare D cell battery and a calibration T fitting. The basic PortaSens II detector does not include sensor modules. Because the PortaSens II is designed to accept any gas sensor, you can select one or more sensor modules. Each sensor module is factory calibrated for the minimum and maximum ranges indicated. The standard factory calibration for the module is listed below. Please choose the sensor below. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
| Description |
Catalog No.
|
| Model C16-1 PortaSens II, 120 VAC Charger |
00-0998
|
| Model C16-2 PortaSens II, 220 VAC Charger |
00-0999
|
Sensor Specifications & Ordering Information
| Gas |
Range
|
Resolution
|
Factory Calibration
|
Part No.
|
| Acid Gases |
0-10/200 ppm
|
0.1 ppm
|
20 ppm
|
00-1038
|
| Acetylene |
0-200/2,000 ppm
|
1 ppm
|
0-500 ppm
|
00-1057
|
| Alcohol |
0-50/500 ppm
|
1 ppm
|
200 ppm
|
00-1043
|
|
0-500/2,000 ppm
|
1 ppm
|
2,000 ppm
|
00-1044
|
| Ammonia |
0-50/500 ppm
|
1 ppm
|
200 ppm
|
00-1010
|
|
0-500/2,000 ppm
|
1 ppm
|
1,000 ppm
|
00-1011
|
| Arsine |
0-500/2,000 ppb
|
1 ppb
|
1,000 ppb
|
00-1024
|
|
0-10/200 ppm
|
0.1 ppm
|
10 ppm
|
00-1025
|
| Bromine |
0-1/5 ppm
|
0.01 ppm
|
2 ppm
|
00-1000
|
|
0-5/100
|
0.1 ppm
|
20 ppm
|
00-1001
|
| Carbon Monoxide |
0-50/1,000 ppm
|
1 ppm
|
200 ppm
|
00-1012
|
| Chlorine |
0-1/5 ppm
|
0.01 ppm
|
2 ppm
|
00-1002
|
|
0-5/100 ppm
|
0.1 ppm
|
20 ppm
|
00-1003
|
| Chlorine Dioxde |
0-1/5 ppm
|
0.01 ppm
|
2 ppm
|
00-1004
|
|
0-1/5 ppm
|
-
|
Low Cl2 Response
|
00-1425
|
|
0-5/100 ppm
|
0.1 ppm
|
20 ppm
|
00-1005
|
|
0-200/1,000 ppm
|
0.1 ppm
|
1,000 ppm
|
00-1359
|
| Diborane |
0-500/2,000 ppb
|
1 ppb
|
1,000 ppb
|
00-1026
|
|
0-10/200 ppm
|
0.1 ppm
|
10 ppm
|
00-1027
|
| Dimethylamine (DMA) |
0-100/200 ppm
|
-
|
100 ppm
|
00-1450
|
| Ethylene Oxide |
0-20/200 ppm
|
0.1 ppm
|
20 ppm
|
00-1039
|
| Fluorine |
0-1/5 ppm
|
0.01 ppm
|
2 ppm
|
00-1006
|
|
0-5/100 ppm
|
0.1 ppm
|
20 ppm
|
00-1007
|
| Formaldehyde |
0-20/200 ppm
|
0.1 ppm
|
20 ppm
|
00-1040
|
|
0-500/0-2,000 ppm
|
1 ppm
|
1,000 ppm
|
00-1349
|
| Germane |
0-500/2,000 ppb
|
1 ppb
|
1,000 ppb
|
00-1028
|
|
0-10/200 ppm
|
0.1 ppm
|
10 ppm
|
00-1029
|
| Hydrogen |
0-1/10%
|
0.01%
|
4%
|
00-1013
|
|
0-500/2,000 ppm
|
1 ppm
|
2,000 ppm
|
00-1041
|
| Hydrogen Bromide |
0-10/200 ppm
|
-
|
20 ppm
|
00-1455
|
| Hydrogen Chloride |
0-10/200 ppm
|
0.1 ppm
|
20 ppm
|
00-1017
|
| Hydrogen Cyanide |
0-10/200 ppm
|
0.1 ppm
|
20 ppm
|
00-1018
|
| Hydrogen Fluoride |
0-10/200 ppm
|
0.1 ppm
|
20 ppm
|
00-1019
|
| Hydrogen Perioxide |
0-200/2,000 ppm
|
0.1 ppm
|
1,000 ppm
|
00-1169
|
|
0-10/100 ppm
|
0.1 ppm
|
20 ppm
|
00-1042
|
| Hydrogen Selenide |
0-500/2,000 ppb
|
1 ppb
|
1,000 ppb
|
00-1030
|
|
0-10/200 ppm
|
0.1 ppm
|
10 ppm
|
00-1031
|
| Hydrogen Sulfide |
0-10/200 ppm
|
0.1 ppm
|
50 ppm
|
00-1020
|
|
0-200/1000 ppm
|
-
|
500 ppm
|
00-1469
|
| Iodine |
0-1/5 ppm
|
0.01 ppm
|
2 ppm
|
00-1036
|
|
0-5/100 ppm
|
0.1 ppm
|
20 ppm
|
00-1037
|
| Nitrogen Dioxide |
0-10/200 ppm
|
0.1 ppm
|
20 ppm
|
00-1022
|
| Nitric Oxide |
0-50/500 ppm
|
1 ppm
|
200 ppm
|
00-1021
|
| NOX |
0-50/0-500 ppm
|
0.1 ppm
|
200 ppm
|
00-1181
|
| Oxygen |
0-5/25%
|
0.1%
|
25%
|
00-1014
|
| Ozone |
0-1/5 ppm
|
0.01 ppm
|
2 ppm
|
00-1008
|
|
0-5/100 ppm
|
0.1 ppm
|
20 ppm
|
00-1009
|
|
0-200/1,000 ppm
|
0.1 ppm
|
1,000 ppm
|
00-1358
|
| Phosgene |
0-1/5 ppm
|
0.01 ppm
|
2 ppm
|
00-1015
|
|
0-5/100 ppm
|
0.1 ppm
|
100 ppm
|
00-1016
|
| Phosphine |
0-500/2,000 ppb
|
1 ppb
|
1,000 ppb
|
00-1032
|
|
0-10/200 ppm
|
0.1 ppm
|
10 ppm
|
00-1033
|
|
0-200/2,000 ppm
|
1 ppm
|
1,000 ppm
|
00-1034
|
| Silane |
0-10/200 ppm
|
0.1 ppm
|
10 ppm
|
00-1035
|
|
0-500/2000 ppb
|
1 ppb
|
1,000 ppb
|
00-1285
|
| Sulfur Dioxide |
0-10/500 ppm
|
0.1 ppm
|
20 ppm
|
00-1023
|
Downloads
|
|
|
Features
Interchangeable smart sensors for over 30 gases
Internal sample pump and external sampling wand
One hand pistol grip design
Standard D cell battery and rechargeable backup battery
Easy to read back lit graphics, LCD
Instantaneous and timed sampling modes of operation
Visual and audible alarms
Internal datalogger with RS-232 output
|