Home > Gas Detection > Fixed Point Gas Detection Systems > F12 Digital Gas Transmitter
NEW!! - Series F12 Digital Gas Transmitter from Analytical Technology
|
|
The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of ATI's explosion proof D12 transmitter. In its standard form, it is deisgned for detection of a variety of toxic gaes in hazardous area applications requiring IS devices. In addition, it is also well suited for all general purpose applications hwere toxic gaes measurement is required. For IS installations, this transmitter is also available with a Hart communication option.
|
F12 Transmitter use ATI's standard smart sensors for maximum flexiblity. Sensors are easily exchanged and contain all calibration constants in sensor memory, eliminating the need for field calibration of transmitters. Sensors may be calibrated separetely on the bench and then simply plugged into the transmitter. Calibration data is read into the transmitter automatically and no other adjustments are normally required. For general purpose gas detection applications, the F12 transmitter is also available in Non-IS versions. One version provides for easy interface to RS-485 networks using a standard MODBUS communication protocol. A second version provides a cmplete AC powered instrument with 3 alarm relays (SPST) available for external alarming.
- Intrinsically Safe Design - Transmitter are designed for use in application requiring intrinsically safe devices for safety purposes.
- Interchangeable Sensors - Every transmitter will accept up to 45 different sensor modules, greatly reducing the need for multiple transmitter models.
- Smart Sensor Modules - Plug in sensors store calibration data, allowing sensors to be calibrated separetly from the transmitter. This allows bench calibration (or factory calibration) of sensors to reduce the necessity for carrying calibration gas around the plant.
- Alarm and Relay Option - A non-IS version of the transmitter provides 3 integral alarm relays. Relays and programmable for setpoint, hysteresis, on-delay and other variables.
- Serial Communication Interface - The IS version of the transmitter is available with Hart communications. The Hart protocol supports the Hart Universal and Common Practice Commands at 1200 baud using the Bell 202 FSK modem standard. The non-IS versions of the transmitter are available with MODUS communications. The MODBUS protocol supports 9600 baud access to concentration and status information and supports alarm setup and many other funcations.
- LCD Graphics Display - Gas concentrations are displayed in large, easy to read numbers. The display also provides alarm indication and complete menus for setting up operating parameters.
- Internal Data Logger - Measured gas values are stored at user desingabl eintervals and can be recalled when needed on the LCD display. Data can be downloaed using a Hart or MODBUS interface.
- Sensor Calibration History - Each time a sensor is zeroed or calibrated, the data is stored in memory. Calibration history can be recalled and sensor condition reveiwed by operating personnel whenever necessary.
- Non-intrusive Operation - Operating funcations such as claibration, alarm setup, alarm reset, data view and setup options are all availabl eusing sealed front panel switches on the face of the Nema 4X transmitter enclosure.
- Password Protection - Program setting stored in the transmitter may be protected by a suer selectable password. Operators may still review all funcations, but changes may only be made up authorized personnel.
- Output Simulation - Transmitter analog outpur can be set to user definalbe values and relay outpurs can be set to specicifc states for complete simultaion of detection system operation. Output and alarms may also be inhibited for maintenance and calibration.
Sensor Specifications
| Gas |
Range
|
Factory Calibration
|
| Acid Gases* |
0-10/200 ppm
|
20 ppm
|
| Acetylene* |
0-50/500 ppm
|
0-200 ppm
|
| Alcohol |
0-50/500 ppm
|
200 ppm
|
|
0-500/2,000 ppm
|
2,000 ppm
|
| Ammonia* |
0-50/500 ppm
|
100 ppm
|
|
0-500/2,000 ppm
|
1,000 ppm
|
| Arsine |
0-500/2,000 ppb
|
1,000 ppb
|
|
0-10/200 ppm
|
10 ppm
|
| Bromine* |
0-1/5 ppm
|
2 ppm
|
|
0-5/200
|
20 ppm
|
| Carbon Monoxide* |
0-50/1,000 ppm
|
100 ppm
|
| Chlorine* |
0-1/5 ppm
|
2 ppm
|
|
0-5/200 ppm
|
20 ppm
|
| Chlorine Dioxide* |
0-1/5 ppm
|
2 ppm
|
|
0-1/5 ppm
|
Low Cl2 Response
|
|
0-5/200 ppm
|
20 ppm
|
|
0-200/1,000 ppm
|
1,000 ppm
|
| Diborane |
0-500/2,000 ppb
|
1,000 ppb
|
|
0-10/200 ppm
|
10 ppm
|
| Dimethyl Amine (DMA) |
0-100/200 ppm
|
100 ppm
|
| Ethylene Oxide* |
0-20/200 ppm
|
20 ppm
|
| Fluorine* |
0-1/5 ppm
|
2 ppm
|
|
0-5/200 ppm
|
20 ppm
|
| Formaldehyde* |
0-20/200 ppm
|
20 ppm
|
|
0-500/2,000 ppm
|
1,000 ppm
|
| Germane |
0-500/2,000 ppb
|
1,000 ppb
|
|
0-10/200 ppm
|
10 ppm
|
| Hydrogen |
0-1/10%
|
4%
|
|
0-500/2,000 ppm
|
2,000 ppm
|
| Hydrogen Chloride* |
0-10/200 ppm
|
20 ppm
|
| Hydrogen Cyanide* |
0-10/200 ppm
|
20 ppm
|
| Hydrogen Fluoride* |
0-10/200 ppm
|
20 ppm
|
| Hydrogen Peroxide* |
0-10/100 ppm
|
20 ppm
|
|
0-200/0-2,000 ppm
|
1,000 ppm
|
| Hydrogen Selenide |
0-500/2,000 ppb
|
1,000 ppb
|
|
0-10/200 ppm
|
10 ppm
|
| Hydrogen Sulfide* |
0-10/200 ppm
|
50 ppm
|
|
0-200/1,000 ppm
|
-
|
| Iodine* |
0-1/5 ppm
|
2 ppm
|
|
0-5/200 ppm
|
20 ppm
|
| Nitrogen Dioxide* |
0-10/200 ppm
|
20 ppm
|
| Nitric Oxide |
0-50/500 ppm
|
200 ppm
|
| NOx |
0-50/500 ppm
|
200 ppm
|
| Oxygen |
0-5/25%
|
25%
|
| Ozone* |
0-1/5 ppm
|
2 ppm
|
|
0-5/200 ppm
|
20 ppm
|
|
0-200/1,000 ppm
|
1,000 ppm
|
| Phosgene |
0-1/5 ppm
|
2 ppm
|
|
0-5/100 ppm
|
100 ppm
|
| Phosphine |
0-500/2,000 ppb
|
1,000 ppb
|
|
0-10/200 ppm
|
10 ppm
|
|
0-200/2,000 ppm
|
1,000 ppm
|
| Silane |
0-10/200 ppm
|
10 ppm
|
|
0-500/2,000 ppb
|
1,000 ppb
|
| Sulfur Dioxide* |
0-10/500 ppm
|
20 ppm
|
(*) Indicates Auto-Test available
A combustible sensor is also available for the D12 system. An Auto-Test is available.
Specifications
| Range |
User adjustable within limits of selected sensor module |
| Response Time |
Sensor dependent |
| Accuracy |
Generally ±10% of value, but limited by available calibration gas accuracy |
| Electronic Repeatability |
±1% of full scale |
| Electronic Linearity |
±0.5% of full scale |
| Zero Drift |
Less than 2% of full scale per month, non-cumulative |
| Span Drift |
Application dependent, but generally less than 3% per month |
| Alarm Relay Option |
Three SPST 5A@ 230 VAC resistive |
| Analog Output |
Loop powered 4-20 mA, 800 ohms maximum at 24 VDC (except combustible gas) |
| Serial Interface |
HART (1200 baud modem interface), MODBUS (1200-9600 - RS-232 or RD-485, software selectable) |
| Power |
12-30 VDC, 25 mA maximum in loop powered mode
12-30 VDC, 200 mA maximum in 3-wire mode |
| Alarm Relays |
Three SPDT, 5A@230 VAC resistive |
| Relay Coil |
Programmable either normally energized or normally deenergized |
| Enclosure |
Explosion proof Class 1, Div 1, Groups B, C, D or NEMA 4X |
| Sensor Type |
Electrochemical for toxic gases and oxygen |
| Controls |
4 magnetic switches on front of transmitter |
| Temperature |
-30° to + 60°C for toxics, -10°C minimum for oxygen sensor |