Home > Gas Detection > Portable Gas Detector > EntryRae Confined Space Monitor

EntryRae - Confined Space Monitor
from Rae Systems

EntryRae Gas Detector

The typical confined space monitor measure oxygen, combustible, carbon monoxide and hydrogen sulfide. Will it keep you safe in today's industrial environment? No. When doing confined space work today, you need the added broadband protection of a PID.

The EntryRae is a 4 gas monitor, plus photo ionization detector (PID). It is reliable, easy to operate and simple to calibrate. The EntryRae delivers added protection without added complexity.

Rae Systems is the leader in PIDs. The plug & play, self cleaning (patented) PID is the most reliable and durable PID available today.

Why a PID?

Typical 4 gas monitors do not detect volatile organic compounds (VOCs). VOCs are combustible and often toxic at levels far below 10% LEL. They are commonly found in:

  • Fuels, oils, degreasers
  • Industrial cleaners
  • Heat transfer fluids
  • Solvents and paints
  • Plastics, resins, adhesives
  • Pesticides and herbicides

These are common industrial compounds you find in - or bring into - a confined space

LEL sensors can be poisoned by common chemicals including

  • Silicone compounds
  • Lead compounds
  • Sulfur compounds
  • Phosphates

Just a few parts per million of these compounds can degrade an LEL sensor.

A PID detects VOCs! A PID is a reliable backup for your LEL sensor. Combine a PID and a 4 gas monitor and you have true protection from the unexpected.

Features

  • Reliable, self cleaning VOC detector
  • Also includes CO, H2S, LEL and O2 sensors
  • Simple to operate
  • Easy to calibrate
  • Durable, weather-resistant rubber body
  • Datalogging included and automatic
  • Big display with auto backlight
  • Loud alarm
  • Bright red flashing LED alarms
  • Up to 16 hours continuous operation
  • Interchangeable Li-Ion and alkaline battery pack
  • Charging cradle doubles as an external battery charger
  • Powerful pump allows sample draws up to 100 feet
  • Low flow pump alarm

Applications

  • Refineries
  • Chemical processing
  • Water & wastewater facilities
  • Semiconductor manufacturing
  • Rail car and tank truck cleaning
  • Resin and nylon production
  • Underground storage
  • Sewer entries
  • Cable vaults
  • Agriculture

Instrument Specifications

Detector Protected catalytic bead for combustible gases
Electrochemical sensors for oxygen, carbon monoxide and hydrogen sulfide
Modular photo ionization detector for broadband detection of VOCs using a 10.6 eV lamp
Battery Drop in rechargeable Li-Ion battery pack
Standard alkaline battery adapter
Charging cradle doubles as external battery charger
Operating Time 16 hours continuous with Li-Ion (typical)
12 hours with alkaline
Display Large 1.4" x 1.8" display with automatic back light in dim light or alarm condition
Key Pads 3 button operation
Direct Readout Instantaneous values: Oxygen as % by vol, Combustible gas as % of lower explosion limit (LEL), toxic gases and VOCs as parts per million by volume
High and low values for all gases
STEL & TWA values of toxic gases and VOCs
Alarm Audible (95 dB at 30 cm) visible and vibration
High: 3 beeps and flashes per second
Low: 2 beeps and flashes per second
STEL and TWA: 1 beep and flash per second
Low battery displays empty battery symbol, 1 beep per minute
EMI/RFI Highly resistant to EMI/RFI. Compliant with EMC Directive 89/336/EEC
Calibration Two point field calibration for zero and standard reference gas
IP Rating IP-55 protected against dust, protected against low pressure jets of water from all directions
Communication PC to monitor via RS232 with USB adapter
Sampling Pump Internal pump, flow rate 500 cc/min
Low Flow Alarm Auto shut off at low flow condition
Temperature -4° to 113°F
Humidity 0 to 95% relative humidity (non-condensing)
Intrinsic Safety UL Class I, Division I, Group A, B, C, D, T3C, CSA pending, ATEX pending
Attachments Stainless steel alligator clip (installed), wrist strap
Size 5.9" L x 3.3" W x 1.9" H
Weight 20 ounces
Warranty Lifetime on non-consuming components
2 years for O2, LEL, CO & H2S sensors
1 year for PID
1 year for battery & pump

Sensor Specifications

Sensor
Range
Resolution
Oxygen
0-30%
0.1%
Combustible Gas
0-100% LEL
1% LEL
0-5% by Vol
1% Vol
VOCs
0-999 ppm
1 ppm
Carbon Monoxide
0-500 ppm
1 ppm
Hydrogen Sulfide
0-100 ppm
1 ppm

Ordering Information

Each instrument includes sensors, filters, manual, alkaline battery adapter, Li-Ion battery, charging cradle, ProRae Studio software, cable and case. The Calibration Kit includes hard transport case, calibration gas, tool kit, sampling wand with 15' of self coiling Teflon tubing and regulators. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
EntryRae with LEL, Oxygen, Carbon Monoxide & Hydrogen Sulfide Sensors, 10.6 eV PID Lamp, and Pump
046-P111-100
EntryRae with LEL, Oxygen, Carbon Monoxide & Hydrogen Sulfide Sensors, 10.6 eV PID Lamp, Pump and Calibration Kit
046-P111-104
New Products | Air Sampling | Gas Detection | Other Meters | Respiratory | Water Quality | WMD HazMat
Applications | Product Specials | Rentals | Links | Index | Contact Us | Home


AFC International, Inc.
PO Box 894, DeMotte, IN 46310
715 SW Almond St, Ste C, DeMotte, IN 46310
800-952-3293 219-987-6825 Fax 219-987-6826
eMail: sales@afcintl.com

Last Revised: 10/4/07