Cal 2000 & Cal 2000LT
Electrochemical Gas Generator

Cal 2000 Electrochemical Gas Generator

The Cal 2000 provides unmatched versatility and accuracy in corrosive calibration gases. Field replaceable, electrochemical generating cells provide a calibration standard for accurately testing chlorine, chlorine dioxide, hydrogen, hydrogen cyanide and hydrogen sulfide gas sensors.

The Cal 2000 is microprocessor controlled and has an LCD display allowing field adjustable ppm and flow rate. The generating cells are interchangeable and field replaceable. Best of all, the Call 2000 provides up to 50 times as much calibration gas as a disposable cylinder at approximately the same cost. The electrochemical generating cells do not degrade over time.

The Cal 2000 gas generator has a built in mass flow sensor that automatically compensates for altitude and temperature.

The mass flow sensor combined with the instruments internal pump, provide extreme flexibility for calibrating both diffusion and sample draw detection systems.

Cal 2000 LT

The Cal 2000 LT is an economical alternative for calibration of corrosive gas detection equipment. The Call 2000 LT is available in preset flow rates of 0.5or 1 LPM. Generating cells are rated at 10 hours and are available for chlorine, hydrogen, hydrogen cyanide and hydrogen sulfide. A gas concentration must be specified when ordering generating cells. To change gas type or concentration simply insert a different cell into the instrument.

Features

  • A compact hand held size
  • NIST traceable certification
  • Low power consumption
  • Alkaline battery powered
  • Adjustable ppm and flow rate
  • Interchangeable calibration gases
  • CSA NRTL/C Exia T-6 approved intrinsicaly safe with CE mark

Specifications

Generator
Cal 2000
Cal 2000 LT
Hydrogen Sulfide
0.5-50 ppm
1-25 ppm
Hydrogen Sulfide Micro-Cell
0.05-1 ppm
-
Chlorine
0.5-50 ppm
1-25 ppm
Chlorine Micro-Cell
0.05-1 ppm
-
Chlorine Dioxide
0.5-5.0 ppm
-
Hydrogen Cyanide
0.5-50 ppm
1-25 ppm
Hydrogen
0.5-50 ppm
1-25 ppm
Air Flow Rate, with internal pump
0.2 to 1 LPM
0.5 or 1 LPM
Sample draw Rate, with pump disabled
0.1 to 5 LPM
n/a
Useful Cell Life
50 or 100 hours
10 hours
Accuracy
+/- 10%
Repeatability
+/- 5%
Warm up Time to 90%
About 5 minutes
Operating Temperature
0 to 50°C
Relative Humidity
0-100%
Battery Power
4 Alkaline C cells
Battery Life
10 hours at 0.5 LPM
Size
8.5" x 4.25" x 3"
Weight 3 pounds
Approvals CSA

Please Note: ppm is variable with flow rate, output given at 0.5 LPM

Ordering Information

The Cal 2000 and Cal 2000 LT include NIST traceable, 5' hose, nylon carrying case, instructions and batteries. For Cal 2000 LT please specify 0.5 or 1.0 LPM flow rate and ppm concentration. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com
Description
Catalog No.
Cal 2000, Order Cell Separately
750-0603-00
Cal 2000 LT, Order Cell Separately
750-0603-LT
Chlorine Cell
510-2000-00
Chlorine Double Life Cell
510-2000-20
Chlorine Micro-Cell
510-2000-05
Chlorine Cell for LT, specify ppm
510-2000-LT
Chlorine Dioxide Cell
510-2060-00
Chlorine Dioxide Double Life Cell
510-2060-20
Hydrogen Sulfide Cell
510-2050-00
Hydrogen Sulfide Micro-Cell
510-2050-05
Hydrogen Sulfide Cell for LT, specify ppm
510-2050-LT
Hydrogen Cyanide Cell
510-2070-00
Hydrogen Cynaide Cell for LT, specify ppm
510-2070-LT
Hydrogen Cell
510-2090-00
Hydrogen Double Life Cell
510-2090-20
Hydrogen Cell for LT, specify ppm
510-2090-LT
New Products | Air Sampling | Gas Detection | Other Meters | Respiratory | Water Quality | WMD HazMat
Applications | Product Specials | Rentals | Links | Index | Contact Us | Home


AFC International, Inc.
PO Box 894, DeMotte, IN 46310
715 SW Almond St, Ste C, DeMotte, IN 46310
800-952-3293 219-987-6825 Fax 219-987-6826
eMail: sales@afcintl.com

Last Revised: 10/4/07