AreaRae Gamma Wireless, Multi-Channel
Multi-Gas and Radiation Monitor
from Rae Systems
The AreaRae Gamma is a combination multi-gas and radiation detector equipped with a wireless RF (radio Frequency) modem which allows the unit to communicate and transmit readings and other information on a real time basis with a remotely located base controller.
In stand alone operation, the AreaRae Gamma is a rugged, weather resistant, portable monitor that can run over 24 hours on either rechargeable lithium ion or alkaline batteries. It is also the first "lunch box" type multi sensor instrument able to include a gamma sensor for measurement of gamma radiation, a photo ionization detector (PID) for parts per million measurement of volatile organic compounds (VOCs), as well as LEL, oxygen and a selectable electrochemical toxic sensor.
The RF modem allows real time data transmissions with a base controller located up to 2 miles away from the AreaRae Gamma detector. A personal computer can be used as the base station for an AreaRae Gamma system. The standard ProRae remote software used to control AreaRae systems is capable of monitoring the input of up to 32 remotely located monitors.
Features
Up to 4 gas sensors (PID, LEL, Oxygen and 1 toxic sensor)
One radiation sensor (Gamma)
Loud buzzer and large, extra bright warning light
Large LCD display and keypad
Rugged, weather proof housing
Built in pump
Interchangeable Li-Ion or alkaline battery pack
Continuous operation via AC source
Real time wireless data transmission with built in RF modem
View real time sensor data and alarm status at headquarters or command center
Fully hardware and software compatible with standard AreaRae 5 gas monitoring system
License free, ISM band RF transmission with communication range up to 2 miles (extendable with RaeLink Repeaters)
Optional GPS provides ability to track and display readings from remote detectors.
Standard AreaRae is factory upgradeable to AreaRae Gamma
Applications
Hazmat and emergency response
Homeland defense
Public venue protection
First responders
Port Security
Border crossings
Sensor Specifications
Sensor
Range
Resolution
Response Time
Oxygen
0-30%
0.1%
15 seconds
Combustible Gas
1-100% LEL
1%
15 seconds
VOCs
0-200.0 ppm
0.1 ppm
10 seconds
200-2,000 ppm
1 ppm
10 seconds
Carbon Monoxide
0-500 ppm
1 ppm
20 seconds
Hydrogen Sulfide
0-100 ppm
1 ppm
30 seconds
Sulfur Dioxide
0-20.0 ppm
0.1 ppm
15 seconds
Nitric Oxide
0-250 ppm
1 ppm
20 seconds
Nitrogen Dioxide
0-20.0 ppm
0.1 ppm
25 seconds
Chlorine
0-10.0 ppm
0.1 ppm
60 seconds
Hydrogen Cyanide
0-100 ppm
1 ppm
60 seconds
Ammonia
0-50 ppm
1 ppm
150 seconds
Phosphine
0-5.0 ppm
0.1 ppm
60 seconds
Gamma Sensor Specifications
Sensor
DER Range
Energy Range
Sensitivity
Gamma
1-4,000 uR/h
(0.01 uSv/h
0.060-3.0 MeV
>100 cps/uSv/h
Specifications
Detector
Up to 5 sensors (radiation, oxygen, combustible, toxic and VOC) electrochemical sensors for toxic gases and oxygen, PID sensor for VOCs, catalytic sensor for combustible gases, scintillation crystal for gamma radiation
Rechargeable, 7.4V/4.5 Ah, Lithium-Ion battery pack with built in charger or a 6 C cell alkaline battery pack
Battery Charger
Less than 10 hours charge thorough built-in smart charger
Display
2 line, 16 digit LCD with automatic LED back light
Keypads
3 operation and 4 programming keys
Direct Readout
Instantaneous values, sensor name, high and low values for all detectors, TWA and STEL values for toxic and VOCs, battery voltage and elapsed time
Alarm
Flashing red LED cluster to indicate exceeded preset limits, low battery or sensor failure
Alarm Setting
Separate alarm limit settings for TWA, STEL, Low and High alarms for VOC toxic gases, Low and high alarm for LEL and radiation
Alarm Mode
Latching or automatic reset
Audible Alarm
100 dB buzzer at 10 cm (typical)
Visual Alarm
Flashing red LED cluster
Datalogging
4,000 points for each sensor with time stamp, serial number, user ID, site ID
Data Storage
20,000 readings (64 hours, 5 channels at 1 minute intervals) in non volatile memory
Datalog Interval
Programmable 1-3,600 seconds
Communication
Upload data to PC and Download monitor setup from PC through RS-232 link to serial port on PC
EM Immunity
No effect when exposed to 0.43 mW/cm2 RF interference (5 watt transmitter at 12")
Calibration
Two point field calibration for fresh air and standard reference gas
Sampling Pump
Internal integrated diaphragm pump with programmable "High" (400CC) and "Low" (300cc) flow rate settings
Low Flow Alarm
Auto shut off at low flow condition
Temperature
-4 to 113°F
Humidity
0 to 95% rH
Size
9.25" x 5.0" x 9.25"
Weight
9.8 pounds
Ordering Information
Each AreaRae includes sensors as specified, filters, calibration adapter, manual, shoulder strap, rechargeable Li-Ion battery pack & charger, alkaline battery pack, water trap adapter, 10 spare external water trap filters, hard transport case, Teflon tubing, and tool kit.. The AreaRae with calibration kit includes all of the above plus calibration gas and regulator. The datalogger version includes software and cable. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or email sales@afcintl.com.